Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S09-023
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/06/2011 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: January 6, 2011 CDRC/Zoning Manager SUBJECT: Triple Crown Villas, 1149 S. Sarnoff Dr. Final Plat S09-023 (First Review) T14S, R15E, Section 16 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used: See note no. 3. " Title Report " Special Warranty Deed " Trust Agreement " Amendment to Trust " Agreement to Construct 3. The titles, assurances included, must match each other verbatim. Per previous comment. 4. The transformer and electrical easements on the north property line are not tied down or surveyable. The survey information for the elec. easements are not legible. Provide details of the electrical easements at a larger scale Revise as required. Per previous comment. 5. The lot for unit no. 19 is encroaching onto common area a. Is it part of the lot, the common area or the ped. easement? Please explain. Any portion of the lot shall not encroach into the right-of-way area. Per previous comment. 6. Identify each block or lot within the subdivision boundary by number, and include the square footage of each. This comment is for lot no. 19. 7. Provide location, dimensions, areas in square footage, and purposes of lots proposed for dedication (such as open spaces, recreation areas, and natural areas) or for reservation for a public use (such as public parks, water facilities, and school sites). The area south of lot 28 that is in between the lot line and right-of-way shall be noted per the requirements above. 8. All boundary monumentation must be labeled as "found" or "set." See note 9. a. Fully describe and show all markings on found monuments with the registrants number and/or "No tag". b. A one-half (½) inch iron rod tagged by a registered land surveyor will be set at all corners upon completion of construction. 9. Indicate tract boundary lines; right-of-way and centerlines of streets, easements, and other rights-of-way; and property lines of residential lots and other sites, with accurate dimensions, bearings, or deflection angles and radii, arcs, and central angles of all curves. Boundary monuments must be set prior to the recordation of the final plat. Indicate that monumentation was set, by a note or call-out, on the final plat. Bearings and Distances are not shown for Lot 19. See note 8. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson - Planning and Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/1149 S. Sarnoff Dr. FP 2 |
01/06/2011 | PMACHAD2 | CC&R | CC&R's | Denied | To: Patricia Gehlen DATE: January 6, 2011 CDRC/Zoning Manager SUBJECT: Triple Crown Villas, 1149 S. Sarnoff Dr. Final Plat S09-023 (First Review) T14S, R15E, Section 16 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used: See note no. 3. " Title Report " Special Warranty Deed " Trust Agreement " Amendment to Trust " Agreement to Construct 3. The titles, assurances included, must match each other verbatim. Per previous comment. 4. The transformer and electrical easements on the north property line are not tied down or surveyable. The survey information for the elec. easements are not legible. Provide details of the electrical easements at a larger scale Revise as required. Per previous comment. 5. The lot for unit no. 19 is encroaching onto common area a. Is it part of the lot, the common area or the ped. easement? Please explain. Any portion of the lot shall not encroach into the right-of-way area. Per previous comment. 6. Identify each block or lot within the subdivision boundary by number, and include the square footage of each. This comment is for lot no. 19. 7. Provide location, dimensions, areas in square footage, and purposes of lots proposed for dedication (such as open spaces, recreation areas, and natural areas) or for reservation for a public use (such as public parks, water facilities, and school sites). The area south of lot 28 that is in between the lot line and right-of-way shall be noted per the requirements above. 8. All boundary monumentation must be labeled as "found" or "set." See note 9. a. Fully describe and show all markings on found monuments with the registrants number and/or "No tag". b. A one-half (½) inch iron rod tagged by a registered land surveyor will be set at all corners upon completion of construction. 9. Indicate tract boundary lines; right-of-way and centerlines of streets, easements, and other rights-of-way; and property lines of residential lots and other sites, with accurate dimensions, bearings, or deflection angles and radii, arcs, and central angles of all curves. Boundary monuments must be set prior to the recordation of the final plat. Indicate that monumentation was set, by a note or call-out, on the final plat. Bearings and Distances are not shown for Lot 19. See note 8. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson - Planning and Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/1149 S. Sarnoff Dr. FP 2 |
01/07/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES January 7, 2011 D. Floyed Thumm Physical Resource Engineering 4655 N. Flowing Wells Rd. Tucson, Arizona 85705 Subject: S09-023 TRIPLE CROWN VILLAS Final Plat Dear Floyd: Your submittal of October, 26, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Final Plat (Addressing, Engineering, PDSD) 2 Copies Assurances (Engineering, PDSD) Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 690-1769 |
12/09/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
12/09/2010 | FERNE RODRIGUEZ | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 2ND FL TUCSON, AZ 85701-1207 AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: S09-023 TRIPLE CROWN VILLAS/REVISED FINAL PLAT DATE: December 9, 2010 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. On the Final Plat: On the Title Blocks add “a portion of” in front of Block 1. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
12/22/2010 | FERNE RODRIGUEZ | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: TRIPLE CROWN VILLAS S09-023 Tucson Electric Power Co. (TEP) approves the final plat submitted for review December 9, 2010. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please forward any resubmittals of the final plat to this office. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Right of Way Agent II Tucson Electric Power Co. offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com <mailto:lcastillo@tep.com> |
12/23/2010 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | December 23, 2010 To: Diana Floyd Thumm Physical Resource Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C Patel, P.E., Civil Eng. Manager Development Review Division ( Wastewater) Subject: Tripple Crown Villas Townhomes, Lots 1-30, Common Areas “A”, “B” “C”& “D” Final Plat – 2nd Submittal S09-023 The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The The PDEQ and the PCRWRD hereby approve the above referenced submittal of the Final Plat received by us on December 09, 2010. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. |
12/29/2010 | STEVE SHIELDS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Triple Crown Villas S09-023 (2ns Review) Final Plat TRANSMITTAL DATE: December 29, 2010 DUE DATE: January 10, 2011 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.and restrictions should match what is shown in the title block of the final plat. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C\planning\cdrc\finaplat\S09-023fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |