Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S09-015
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/04/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/05/2011 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 10/13/2011 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 October 12, 2011 To: Paul Nzomo CORONADO ENGINEERING Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________________ From: Tom Porter, Sr CEA(520-740-6719), Pima County Regional Wastewater Reclamation Department Subject: Silverbell Crossing Tentative Plat –3rd Submittal S09-015 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the tentative or preliminary plat as submitted. cc: Chad Amateau, PE Checked by:_________ Kristin Greene, PE, DLU Manager DLU Project folder |
| 10/13/2011 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: S09-015 SILVEREBELL CROSSING/REVISED TENTATIVE PLAT DATE: October 12, 2011 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 10/17/2011 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approv-Cond | DATE: October 17, 2011 TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Silverbell Crossings Tentative Plat 3rd submittal Engineering Re-review REVIEWER: Elizabeth Leibold ACTIVITY NUMBER: S09-015 SUMMARY: The revised Tentative and Final Plats (old case number: S04-188), was reviewed by Planning & Development Services Department Engineering Division. Conditional approval is recommended with the following items to be addressed on Tentative Plat mylar. TENTATIVE PLAT CONDITIONS OF APPROVAL: Address the remaining items for Tentative Plat: 1) DS Sec.2-03.2.4.L.6: The zone A FEMA revised floodplain limits effective June 16, 2011 per DFIRM 1669L is required to be labeled on the plat. Add label and delineations for the FIRM panel L information on Tentative Plat. Sheets 4 & 5 with old FEMA 1619K flood limits must be updated to show the new 1669L limits and the FEMA 1619K flood limits should be removed from the plat as there is no engineering information provided by this outdated floodplain line, and it shows discrepancy for flood insurance purposes. Design flood limits shall remain. Also revise note 35 to clarify that the subdivision is impacted by a FEMA SFHA however the subdivision's residential lots are not within the regulatory floodplain including the FEMA SFHA. For the subsequent Final Plat submittal, please be aware that the limits of the 100-year floodprone area shall be shown in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines for all flows of one hundred (100) cfs or more. 2) DS Sec.2-03.2.4.M: Show basin setback per geotechnical report for lots 98-102. Submit revised Tentative Plat and a detailed response letter. If you have questions or would like to schedule the meeting, call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Dept |
| 10/18/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES October 18, 2011 Paul Nzomo Coronado Engineering & Development Inc. 4007 E. Paradise Falls Dr. # 125 Tucson, Arizona 85712 Subject: S09-015 SILVERBELL CROSSING Tentative Plat Dear Paul: The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the plans per the on-line comments. Please submit the following documents for sign-off: 1 Set of the Plat, Landscape Plan and NPPO. Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City’s contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your prints to the CDRC office for sign-off approval. The printing company will deliver the original stamped print set to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. A tentative plat is valid for a period of three (3) years after the date of approval. This Tentative plat will expire on 10/18/14 per LUC 4.1.7.2. The Final plat must be approved by Mayor and Council and recorded within three (3) years of date of approval of the tentative plat per LUC 4.1.7.3. Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 722-5394 |