Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S09-015
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - FINAL PLAT REVIEW

Plan Number - S09-015
Review Name: REVISION - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/24/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/28/2011 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S09-015
Silverbell Crossings
Tentative Plat and Final plat comments

TRANSMITTAL DATE: March 28, 2011

DUE DATE: April 7, 2011

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. This is a re-subdivision of the previously approved and recorded plat. (Silverbell Crossings Book 62 page 65). The title block needs to reflect that this is a re-subdivision of the previous plat.

In addition, it is advised that the applicant verify with Pima County Subdivision Coordinator with regards to the name. Typically the county does not allow two different subdivision plats be recorded with the same name.

If the CC&Rs must be revised to reflect the new subdivision name and recordation of the plat, assure that the CC&Rs are drawn up to reflect the new name.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C:\planning\cdrc\tentativeplat\S09015.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat, final plat, CC&R's and additional requested documents.
03/30/2011 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied >>> <MBurke@tep.com> 03/30/2011 3:29 PM >>>
SUBJECT: Silverbell Crossing Replat

Lots 1-143

S04-188, S09-015



Tucson Electric Power Company (TEP) has received the final plat
submitted for review March 24, 2011. TEP is unable to approve the plat
at this time.



When the Tentative Plat has been approved by the City of Tucson, please
submit to my attention a copy of the signed Approved Tentative Plat.
TEP will provide an electrical design within twenty (20) working days
upon receipt of the plat and the required additional plans. The
completion of the electrical design is necessary to determine our
easement requirements and review the final plat.



Additional plans necessary for preparation of the design are: building
plans including water, electrical, landscape, sidewalk and paving plans.
Also, submit the AutoCAD version of the plat on a CD or email to
mburke@tep.com <mailto:mburke@tep.com> .



Electronic AutoCad Plan format:

1. An Electronic AutoCad plan must be complete and identical to the
official hard copy (paper) project (subdivision, commercial) plat.

2. The AutoCAD plan must be a civil site plan drawing. (The
majority of time an electrical site plan drawing does not have the
required information.)

3. A single AutoCAD plan drawing containing all the layers should be
submitted.

4. AutoCAD plan should be in DWG format.

5. AutoCAD Version can be 2007 or lower.

6. 2D only, not 3D (Please take out reference images and 3D images.)

7. Please take out the topography Layer.

8. Layers relate to a unique set of CAD features within the drawing.
(For example all lot lines should be on one layer, street centerlines
another layer.)

9. Include the required Layers: Lot Lines, Right of Way lines,
Street Centerlines, Buildings, Curbs, Basin, Section Lines, Boundary
of Property, Footages, Bearings, Lot Numbers, Street Names, and Tie Down
(Section or Quarter Pins.)

10. At least three tie points are required; one must be a Section or a
Quarter pin and the others may be street intersections or lot corners.
Bearings and distances must be designated from the tie points.

11. Please include the Boundary Line of Property. It must be
designated with bearings and distances.

12. Any special fonts, X-REFs, or attachments should be submitted along
with the CAD drawing.

Please contact me at (520) 917-8744 if you have any questions.



Thank you,





Mary Burke

Associate Right of Way Agent

Tucson Electric Power Co.

offc-(520) 917-8744

fax-(520) 545-1567

cell-(520) 401-9895

mburke@tep.com
03/30/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S09-015 SILVERBELL CROSSING/FINAL PLAT
DATE: March 30, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Include the resubdivision information on all title blocks.
Change T-3-S to T-13-S under the Location Map.
04/06/2011 ELIZABETH LEIBOLD ENGINEERING REVIEW Denied DATE: April 6, 2011
TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Silverbell Crossings Final & Tentative Plat 1st submittal Engineering Re-review
REVIEWER: Elizabeth Leibold
ACTIVITY NUMBER: S09-015

SUMMARY: The revised Tentative and Final Plats (old case number: S04-188), was reviewed by Planning & Development Services Department Engineering Division. Approval is not recommended at this time until the following comments are addressed.

FINAL and TENTATIVE PLAT COMMENTS:
1) Any remaining conditions from the previous plat still apply.
2) Provide the following documentation for Tentative Plat:
a) D.S. 2-03.2.4.K: Copy of geotechnical reports and addenda, including the geotechnical addenda regarding the details showing slopes that exceed 2:1 (H:V).
b) DS Sec.2-03.2.3: Documentation from WAPA regarding acceptance of the proposed improvements within the WAPA easement.
c) Golf Course correspondence that verifies acceptance of flows from project as shown on the proposed Tentative Plat.
d) Provide copies of drainage reports and any addenda for the onsite and Silverbell Road drainage. Onsite Drainage Report will need to include a maintenance list for all proposed drainage improvements and common areas that will be maintained by the HOA.
e) The docket and page for both the south slope / access easement and the drainage easement for the pipe from basin to Golf Course. Label on Final and Tentative Plats.
f) WAPA correspondence.
g) Other engineering associated documents that were accepted for the subdivision.
h) Any applicable variance documentation.
3) Explain how General Note 32 H on sheet 1 of Tentative Plat is met for this project.
4) It is recommended that the floodplain information reflect upcoming DFIRM data effective June 16, 2011, since final plat approvals may occur around time of the effective date of the new panel. Add label and delineations for the FIRM panel L information on Final and Tentative plat. Other flood data may remain on the sheets unless there is new drainage information from Silverbell improvements.
5) Explain proposed pipes adjacent to lot 61 at new entrance area on sheet 7 of the Tentative Plat. Explain and provide analysis with q100, velocity, erosion protection (especially for the existing monitoring wells), with additional grading detail for the area near the existing monitoring wells.
6) Explain water easement that was originally shown on previous plat that was located at south corner of project, and whether this is entirely within the new Baby Bruno alignment.
7) DS Sec.2-03.2.4.M: Show basin setback per geotechnical report for lots 98-102.
8) DS Sec.2-03.2.2.B.6: Label slope details to include "hand placed" rip rap per the variance if variance is still valid.
9) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. For third party trust subdivision assurances, provide full copy of new assurance documents.
10) Assure that the descriptions of the common areas of the Final Plat title block match the CC&R's descriptions of the subdivision common areas and the descriptions in the assurance paperwork. Please be aware that the legal office may reject the assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block.
11) Sequencing numbers are required for final plats.
12) DS Sec.2-03.6.5.B: Assure that all easements listed on the Schedule B of title report are clearly drawn, labeled with Book/page or Docket/page, and/or listed as a blanket easement, and/or labeled with accurate dimensions and bearings on the plat.

Submit revised Tentative Plat, assurances, and other documentation with a detailed response letter. If you have questions or would like to schedule the meeting, call me at 837-4934.

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Dept
04/11/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

April 11, 2011

Paul Nzomo
Coronado Engineering & Dev inc.
4007 E. Paradise Falls Dr. # 125
Tucson, Arizona 85712

Subject: S09-015 SILVER CROSSINGS Final Plat

Dear Paul:

Your submittal of March 24, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 6 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Final Plat (Zoning, Addressing, TEP, Engineering, Wastewater, PDSD)

3 Copies CC&R's (Zoning, Engineering, PDSD)

2 Copies Assurances (Engineering, PDSD)

1 Check Made out to "Pima County Treasurer" for $50.00 (Wastewater)

Should you have any questions, please call me at 837-4893.

Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 722-5394
04/11/2011 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Denied April 7, 2011

To: Paul Nzomo, P.E.
Coronado Engineering & Development

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C Patel, P.E., Civil Eng. Manager
Development Review Division ( Wastewater)

Subject: Silverbell Crossing, Lots 1-143 and Common Areas “A” Thru “E”
Final Plat – 1st Submittal, S09-015


The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. Sheet 1:DEDICATION, 3rd para, 1st line, add PIMA COUNTY, between PUBLIC and AND.

2. Sheet 1: DEDICATION, 4TH para, 4th line, add PIMA COUNTY, between PUBLIC and AND.

3. All Sheets: Show the project number S09-015 in the Title Block.

4. The review comments on the Tentative Plat of this project were transmitted to the Engineer on 4-06-11. These comments need to be addressed before the review of this Final Plat can be completed.

5. The Sewer Service Agreement for this project needs to be executed. Please contact Mike Harrington of the PCRWRD for this purpose.

6. Sheet 1: The Owner/Developer shown on the Tentative Plat is different from what is shown on this Final Plat. This discrepancy needs to be corrected.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines .


If you have any questions regarding the above comments, please do not hesitate to contact me.