Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S08-086
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/14/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Passed | |
| 07/21/2008 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: INDUSTRIAL CENTER TUCSON AIRPORT S08-086 Tucson Electric Power Company has reviewed and approved the Final Plat submitted for review July 10, 2008. In order to apply for electric service, call the New Construction Department at (520) 770-2062. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Please call me at (520) 917-8745, should you have any questions. Liza Castillo, Right of Way Agent II Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
| 07/22/2008 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 07/24/2008 | ANDY DINAUER | PIMA COUNTY | WASTEWATER | Denied | July 24, 2008 TO: Dan Castro Rick Engineering THRU: Patricia Gehlen, CDRC Manager City of Tucson, Development Services Department FROM: Chandubhai C. Patel, P.E., Civil Eng. Manager Development Review Division (Wastewater) Pima County Development Services Department SUBJECT: Industrial Center Tucson Airport, Lots 1 & 2 Final Plat, SO8-086 1st Submittal The drawings for the proposed Final Plat for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. ALL SHEETS. Add the Project No. S08-086 to the Title Block. This number should be shown bold and larger than any other cross-reference numbers. Show all necessary sanitary sewer easements. 3. A Development Plan for this project needs to be submitted and approved before this Final Plat can be approved. If the DP has already been approved, please show its project number as a cross-reference number. This office will require a submittal of the revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. The next submittal of this project will be the second ( 2nd ) submittal. A check for the review fee of this submittal in the amount of $150.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai C. Patel, P.E. CC: Project File |
| 07/28/2008 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | Request the following to Sht. 2 & 3 of 3; -Elvira Road to the North be changed to Aragon Road. -Brosius Avenue to the South be changed to Elvira Avenue. -Provide recording information in the spaces for Water and Sewer easements. On all sheets, fill in the S08-___ with S08-086. |
| 07/31/2008 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S08-086 Industrial Center Tucson Airport Final plat TRANSMITTAL: 07/31/2008 DUE DATE: 08/05/08 COMMENTS: 1. An applicant has one (1) year from the date of submittal to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 07/09/09. 2. There has been submitted a site plan for this site (T08CM00528) which has not been approved as of the time of this review. Provide a copy of the approved site plan with the next submittal. Additional comments may be forth coming. 3. The streets indicated on the final plat are not correct. Location of Elvira Rd. is along the south side of this property and Aragon Rd. is located along the north side. Revise. 4. DS 2-03.6.1.K Case number S08-086 has been assigned to this final plat. Please place this number in the right corner of all sheets of final plat 5. Provide docket and page recording information for the indicated water and sewer easements. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\finalplat\S08-086fp.doc |
| 08/01/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S08-086 INDUSTRIAL CENTER TUCSON AIRPORT/FINAL PLAT DATE: 7/29/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change Elvira Road to Aragon Road on pgs. 2 & 3. Change Brosius Avenue to Elvira Road on pgs. 2 & 3. |
| 08/04/2008 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: August 4, 2008 SUBJECT: Industrial Center Tucson Airport Final Plat Submittal- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 6850 S Brosius Ave, T13S R14E Sec 35 Ward 2 REVIEWERS: Jason Green, CFM ACTIVITY: S08-086 SUMMARY: Engineering Division of Development Services Department has received, Sheets 1 thru 3 of the proposed Final Plat, a copy of the CC&Rs and a copy of the Title Report. Engineering Division has reviewed the submitted Final Plat, CC&Rs and Title Report and does not recommend approval of the Final Plat at this time. The following items need to be addressed: FINAL PLAT COMMENTS: 1) The Final Plat can not be approved until Site Plan and Grading Plan approval. The associated Site Plan (T08CM00528) and Grading Plan (T08BU00855) have yet to be approved by Development Services therefore the Final Plat could not be shown to be in conformance with building locations, basin dimensions, Vehicular Use Areas, etc. The Final Plat must reflect any required changes from the Site Plan and Grading Plan comment letters that have been posted under separate reviews. 2) DS Sec.2-03.6.1.E: Revise Sheet 1 to include an index of all sheets included with the Final Plat submittal, or provide a small index drawing of the site showing the area represented on each sheet. 3) DS Sec.2-03.6.1.H.1: Revise the title block on the proposed Final Plat and/or all applicable wording in the CC&Rs to match each other. All names, common areas, and descriptions must have the same wording in the CC&Rs as in the Title Block. Provide a clear definition of each Common Area within the Title Block. 4) DS Sec.2-03.6.1.K: Revise the Final Plat to indicate the subdivision cases number assigned (S08-086) where indicated by "S08-", it may be added to the lower right hand corner of the plans on all sheets. 5) DS Sec.2-03.6.2.H: Revise General Note # 6 to correct the typographical error by adding the "ed" to the word 'express.' Refer to the referenced section for the complete accurate note that must be on the Final Plat. 6) DS Sec.2-03.6.2.I: Provide the following note on the Final Plat (if the subdivision is the result of a rezoning case); "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expensive to the public." 7) DS Sec.2-03.6.4.A: Revise the Final Plat to include the recordation information for all proposed public easements that are depicted on the plat. Final Plat can not be approved prior to the recording and posting of these easements. 8) DS Sec.2-03.6.4.A: Revise the Final Plat to correctly label the existing streets with the correct name. Verify that the recordation information shown is correct once the plat is revised. Specifically Elvira and Aragon are either incorrectly labeled or not shown. 9) DS Sec.2-03.6.4.C: Revise the Final Plat to clearly enclose with a solid line each common area, label the common area individually with a separate letter designation that will have separate restrictions, a separate homeowners' association, or any common area that is separated by a public right-of-way. Specifically for all proposed basins, vehicular use areas, landscaping, etc. 10) DS Sec.2-03.6.5.A: Revise the Final Plat to indicate primary control points, or descriptions and ties to such control points, to which all dimensions, angles, bearings, and similar data on the plat will be referred. Specifically, at least one (1) corner of the subdivision must be tied by course and distance to the section corner or the quarter section corner shown on the Final Plat that was used to establish the basis of bearing. The plat must include an accurate description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. All Found Brass disc must be clearly described. 11) DS Sec.2-03.6.5.C.1.a: Revise General Note # 4 the Basis of Bearing Section to include the recordation information of the referenced subdivision of Airport Commerce Center Lots 1 thru 81. 12) DS Sec.2-03.6.5.C.4: Revise the Final Plat to fully describe all found brass discs that are shown. All found monuments must be fully described and show all markings on the found monuments. 13) DS Sec.2-03.6.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between monuments were measured or calculated for all property line boundary information. The legend shows the symbols used for measured, calculated or recorded, but these are not clearly shown on the plat with the provided dimensions, revise. 14) DS Sec.14.3.2: Provide a note on the Final Plat stating that, (a) the owner or owners shall be solely responsible for operation, maintenance, and liability for drainage structures and retention basin; (b) that the owner or owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and retention facilities at lease once each year, and that these regular inspection reports will be on file with the owner for review by City staff, upon written request; (c) that City staff may periodically inspect the drainage and retention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and (d) that the owner or owners agree to reimburse the City for any and all costs associated with the maintaining of the drainage and retention facilities, should the City find the owner or owners deficient in their obligation to adequately operate and maintain their facilities." 15) DS Sec.2-03.6.6: A final signed original copy of the CC&Rs is required for approval of the Final Plat. The Final Plat can not be approved prior to original CC&Rs being submitted and approved. 16) DS Sec.2-03.6.6.A: Revise the CC&Rs to accurately reflect all of the proper common area labels and responsibility for maintenance and liability for any proposed commonly-owned areas. Revise the following information within the CC&Rs: a) Revise to accurately describe the property (Name, number of lots, common areas, with descriptions) per the Title Block. Either the CC&Rs or the Title Block must be revised and must match with exact wording for the name and all common areas. b) DS Sec.14.3.2: Provide a note in the CC&Rs under Article 3 stating that, (a) the owner or owners shall be solely responsible for operation, maintenance, and liability for drainage structures and retention basin; (b) that the owner or owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and retention facilities at lease once each year, and that these regular inspection reports will be on file with the owner for review by City staff, upon written request; (c) that City staff may periodically inspect the drainage and retention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and (d) that the owner or owners agree to reimburse the City for any and all costs associated with the maintaining of the drainage and retention facilities, should the City find the owner or owners deficient in their obligation to adequately operate and maintain their facilities." c) Provide both Exhibit A and B within the CC&Rs. All exhibits must be provided in order for the CC&Rs to be a complete package. d) Revise the CC&Rs so that the pages or numbered in sequential order beginning with the first page (exhibits are not numbered). 17) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until Financial Assurances are submitted and approved. Since this project does not have an approved site plan or grading plan and the improvements have yet to be constructed Financial Assurances are required. GENERAL COMMENTS: Provide the last approved site plan, approved grading plan, a revised Final Plat, a revised original CC&R package and a Financial Assurance Package at re-submittal. The revised Final Plat, CC&Rs and Assurance Package must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the Final Plat, CC&Rs and Assurance Package. If you have any questions or to schedule a meeting I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 08/22/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 22, 2008 Dan Castro Rick Engineering Company, Inc. 1745 East River Road, Suite 101 Tucson, Arizona 85718 Subject: S08-086 Industrial Center Tucson Final Plat Dear Dan: Your submittal of July 10, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Final Plat (Wastewater, Real Estate, Zoning, Addressing, Engineering, DSD) 2 Copies Last approved site and grading plans (Engineering, DSD) 2 Copies Original CC&R's and assurance package (Engineering, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 fpresubmittal |
| 08/22/2008 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: August 4, 2008 RE: Assessor’s Review and Comments Regarding Final Plat S08-086 Industrial Center Tucson Airport T151416 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |