Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S08-085
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/16/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/31/2009 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 04/02/2009 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: April 2, 2009 SUBJECT: Kippes Town Homes Tentative Plat- 3rd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 7830 E Uhl Street, T14S R15E Sec17 Ward 2 REVIEWERS: Jason Green, CFM ACTIVITY: S08-085 SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Tentative Plat, Drainage Report for Kippes Town Homes (JE Fuller Hydrology and Geomorphology, Inc., 30DEC08), copy of the Declaration of Covenants, Conditions and Restrictions, (CC&Rs), Landscape Plans and a copy of the Title Report. The revised Tentative Plat is conditionally approved at this time. The following item need to be addressed prior to final Tentative Plat approval: TENTATIVE PLAT: 1) Complied. 2) Complied. 3) Complied. 4) Complied. 5) Complied. 6) Complied. 7) Complied. 8) Complied. 9) Complied. 10) Complied. 11) Complied. 12) Complied. 13) Complied. 14) Acknowledged, however the DSMR box shown on Sheet C2 must include the date of approval for the DSMR prior to final Tentative Plat approval. 15) Complied. 16) Complied. 17) Acknowledged, however an original, signed, notarized CC&Rs is required with the Final Plat for recordation purposes. 18) Complied. Drainage Report for Kippes Town Homes; JE Fuller Hydrology and Geomorphology, Inc., 30DEC08. 19) Complied. 20) Complied. Refuse accessibility and design reviewed and approved per COT Environmental Services. Copy of email from Andy Vera forwarded to Records. 21) Complied. 22) Acknowledged. DRAINAGE STATEMENT: 23) Complied. Drainage Report for Kippes Town Homes; JE Fuller Hydrology and Geomorphology, Inc., 30DEC08. GRADING PLAN: 24) Restated: DS Sec.2-03.5.2: For future references a grading permit application will be required for this project. A grading permit may not be issued prior to Tentative Plat approval. 25) Restated: Please ensure the grading plan is consistent with the Tentative Plat and Drainage Statement. Grading standards may be accessed at http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf. GENERAL COMMENTS: Provide a revised Tentative Plat showing the dates of approval for the Development Standard Modification Request (DSMR) on Sheet C2 at re-submittal. If you have any questions, I can be reached at (520) 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 04/03/2009 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | April 1, 2009 To: NORMAN A. AMY IDC - INTEGRATED DESIGN AND CONSTRUCTION Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Tom Porter , Sr CEA Development Review Division Subject: KIPPES TOWN HOMES Tent. Plat – 3rd Submittal S08-085 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above-mentioned comments, please contact me. |
| 04/06/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 04/08/2009 | TERRY STEVENS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S08-085 Kippes Townhomes, Residential Cluster Project Tentative Plat, 2nd Review TRANSMITTAL DATE: April 8, 2009 DUE DATE: April 13, 2009 COMMENTS: 1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements. 2. Per DS 2-03.2.2.B.6, Remove general note #6 regarding DDOs. Revise general note #27 to read as follows: "This project is design to meet the overlay zone criteria for Sec. 3.6.1, Residential Cluster Project (RCP)." 3. Per DS 2-03.2.4.G Provide a note stating the DSMR case number, what the DSMR is for, date of approval and any conditions of approval. If approved without conditions, state such on the plans. Date of approval for both DSMRs is missing. 4. Per DS 2-03.2.4.M, Provide setback notes on sheet C1, note #5, clarifying that subdivision boundary setback from the west property line is 10' or ¾ the height of the structure due to adjacent R-3 zoning, not 20' as indicated. Site Data portion of C-1 5. The parking calculations in the site data portion of sheet C-1 are incorrect. Revise. The number of required parking spaces per 3 bedroom unit is 2 with and additional 1 per unit for visitor parking thus requiring a total of 24. Reduced from 8 visitor parking spaces required to 6 by DSMR for a total of 22 parking spaces provided. Provide the number of required and provided parking spaces. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\tentativeplat\S08-085-3tpca.doc |
| 04/23/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES April 23, 2009 John F. Millar Planner Designer 4930 S. Mesquite Club Lane Tucson, Arizona 85706 Subject: S08-085 Kippes Townhomes Tentative Plat Dear John: The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the bluelines per the on-line comments. Please submit the following documents for sign-off: 1 Blueline set of the Plat, Landscape Plan and NPPO. Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your bluelines to the CDRC office for sign-off approval. Your printing company will deliver the stamped blueline set to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PRIOR TO SUBMITTING THE FINAL PLANS TO THE CDRC OFFICE, PC ADDRESSING MUST REVIEW AND APPROVE THE PLANS. THE APPROVAL MUST BE IN WRITING (E-MAIL IS OKAY). Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 881-6832 |
| 04/23/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approv-Cond | Applicant to have final drawing approved by PC Addressing. |
| 04/23/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S08-085 KIPPES TOWNHOMES/REVISED TENTATIVE PLAT DATE: 4/29/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project PENDING: Correct the scale on the Location Map 3”=1 mile. On the sunbdivison key #13 lot numbers should be 80-159. On subdivision key #14 lot numbers should be 1-160. On sheet 1 correct duplicate lot 6 to lot 8. On sheet 3 in private sewage box delete the word units and add the word lots. On sheet 3under the wastewater pressure and demand box delete the word units and add the word lots. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 04/23/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S08-085 KIPPES TOWNHOMES/REVISED TENTATIVE PLAT DATE: 4/29/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project PENDING: Correct the scale on the Location Map 3”=1 mile. On the sunbdivison key #13 lot numbers should be 80-159. On subdivision key #14 lot numbers should be 1-160. On sheet 1 correct duplicate lot 6 to lot 8. On sheet 3 in private sewage box delete the word units and add the word lots. On sheet 3under the wastewater pressure and demand box delete the word units and add the word lots. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S08-085 KIPPES TOWNHOMES/REVISED TENTATIVE PLAT DATE: 5/15/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County's Geographic Information System. Your support is greatly appreciated.*** |