Plan Number: S08-075
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL-FINAL PLAT - CONDO CONVERSION

Plan Number - S08-075
Review Name: RESUBMITTAL-FINAL PLAT - CONDO CONVERSION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/12/2008 DAVID MANN COT NON-DSD FIRE Denied Condominiums require fire sprinklers, townhouses do not. Provide fire sprinklers. See IFC Chapter 2 amendments and IFC Chapter 9.
08/14/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
08/15/2008 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: T.A. MILLER TOWNHOMES

S08-075



Tucson Electric Power Co. (TEP) approves the final plat submitted August
8, 2008.

Please forward any resubmittals of the final plat to this office.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent II
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com <mailto:lcastillo@tep.com>
08/22/2008 CDRC1 PIMA COUNTY WASTEWATER Approved August 21, 2008

To: Alan W. Stephens
Hawkeye Land Surveying Co.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Eng. Manager
Development Review Division (Wastewater)

Subject: TA Miller Townhomes Units 2, 3, 4, 5, and 6, Common Area "A" and Limited Common Element "B", A Condo Conversion Project.
Final Plat - 2nd Submittal, S08-075


The drawings for the proposed Final Plat for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (RWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The PDEQ and the RWRD hereby approve the above referenced submittal of the Final Plat as received by us on August 7, 2008. This is a condominium conversion project.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above comments, please do not hesitate to contact me.
08/22/2008 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor's Office
Mapping Department

DATE: 08/22/08


RE: S08-075 Assessor's Review and Comments Regarding Final Plat


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
09/03/2008 HEATHER THRALL ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department, Plans Coordination Office

FROM: Heather Thrall, Senior Planner

PROJECT: S08-075, T.A. Miller Townhomes, a Conversion of Apts. To Condos
7480 E. Speedway Blvd., O-3, Final Plat, 2nd Review

TRANSMITTAL DATE: September 2, 2008

DUE DATE: September 4, 2008

COMMENTS: CONDITIONAL APPROVAL


1. For clarification, after the public sewer, utility, pedestrian and ingress/egress easement notation - add the words "per this plat".

2. Per DS 2-03.6.6.A, please remove reference to "A Residential Cluster Project" in note 13 of article I, describing the properties. This is not an RCP, it's an apartment complex converted to condos.

3. Per discussions with Engineering division, please separate the cubic volumes of the air space in each condo from the garage cubic volume, and label that area as limited common element B with the cubic volume of that space.



Please note, depending upon responses provided, further review comments may be forthcoming. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951.

C:\planning\cdrc\finalplat\S08-075 TA Miller condos 7480 E Speedway 2.doc
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's.
09/03/2008 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: S08-075 T.A. MILLER TOWNHOMES/FINAL PLAT
DATE: 9/02/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1.) The Location Map must be 3"=1 mile per letter dated 6/26/08.
2.) Change 11-Saquaro to Saguaro on Location Map.




es
09/08/2008 PAUL MACHADO ENGINEERING REVIEW Approved
09/09/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 9, 2008

James W. Gerlach
J.G. Construction Company, LLC
9020 East Eagle Place
Tucson, Arizona 85749

Subject: S08-075 T.A. Miller Townhomes Final Plat

Dear James:

Your submittal of August 8, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Final Plat (Fire, Addressing, Zoning, DSD)






Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 760-2675
fpresubmittal