Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S08-071
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/23/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/28/2009 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 05/04/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 05/11/2009 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Denied | May 7, 2009 To: Kent Delph, Delph Engineering Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E., Civil Eng. Manager Development Review Division (Wastewater) Subject: Colonial Solana,Lots 1-4 Final Plat – 2nd Submittal S08-071 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Show on Sht 1, the S08…. Number for Improvement and Grading Plan as the Cross Reference number near the Title Block. Sheet 1 Add words “Private Sewer” to the label for the 32 feet easement shown on the drawing. The following comments refer to the Improvement Grading Plan, since that is where the sewers information is shown: Show the City assigned project number for this project near the Title Block. Sheet 1: Modify note no. 16 since you do not have any public sewer on site as per the approved Sewer Improvement Plan (offsite). Sheet 2: Update this drawing to reflect the sewers shown on approved G-2006-149. There are no proposed onsite public sewers any more. Show on this drawing G-2006-149 as the cross reference number. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third submittal. A check for the review fee of this submittal in the amount of $117.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. |
| 05/13/2009 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 05/27/2009 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 06/01/2009 | PGEHLEN1 | CC&R | CC&R's | Approved | |
| 06/01/2009 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review | |
| 06/01/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES June 1, 2009 Kent A. Delph, P.E. Grenier Engineering, Inc. 5517 East 5th Street Tucson, Arizona 85711 Subject: S08-071 Colonial Solana Final Plat (formerly S05-250) Dear Kent: Your submittal of April 23, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Final Plat (Wastewater, DSD) The review period for this plan has expired. Prior to resubmittal, the CDRC must grant an extension to this review period. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 326-7508 fpresubmittal |