Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S08-071
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S08-071
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/05/2008 RONALD BROWN ZONING HC SITE REVIEW Approv-Cond 1. INSURE CURB RAMPS AT BROADWAY STREET AS REQUIRED BY COT DOT SD 207
2. INSURE DEVELOPEMENT COMPLIANCE WITH "THE INCLUSIVE HOME DESIGN ORDINANCE" NUMBER 10463. A COPY MAY BE OBTAINED FROM THE DSD WEB SITE UNDER CODE AND ORDINANCES.
3. PROVIDE 2006 IBC OCCUPANCY CLASSIFICATION
06/06/2008 JIM EGAN COT NON-DSD FIRE Approved
06/13/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Add the CDRC subdivision case number (S08-071) and any other related case numbers to all sheets of the plat, and native plant preservation plan.

2. Revise text in the site location map on sheet L-1 to meet the minimum required size of 12 point (0.12"). Refer to the site location map on final plat sheet 1 of 3 for acceptable standards for legibility and archiving.
06/18/2008 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: COLONIAL SOLANA

S08-071



Tucson Electric Power Co. (TEP) approves the final plat submitted June
4, 2008.

Please forward any resubmittals of the final plat to this office.



Electric service will be provided to this subdivision in accordance with
the rules and regulations approved by the Arizona Corporation
Commission.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent II
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
06/20/2008 ANDY STEUART COT NON-DSD REAL ESTATE Approved
06/23/2008 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S08-071 COLONIAL SOLANA/MINOR SUBDIVISION REVIEW
DATE: 6/23/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


Note: ON FINAL MYLAR:

1.) Delete 126-212-0120 A portion of Lot 12.





***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
06/24/2008 FRODRIG2 PIMA COUNTY WASTEWATER Denied June 20, 2008

To: Kent Delph, Delph Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Colonial Solana
Lots 1-4
Final Plat – 1st Submittal
S08-071

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


We can not approve the Final Plat until the tentative/site plan has been approved. The site plan will need to be formally submitted with the proper fees. The fee for the first submittal is $166 plus $50 per sheet.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.

If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter
06/27/2008 TERRY STEVENS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S08-071
Colonial Solana
Final Plat - Minor Subdivision

TRANSMITTAL: 06/27/2008

DUE DATE: 07/01/08

COMMENTS:

1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

2. DS 2-03.6.1.K Case number S08-071 has been assigned to this final plat. Please place this number in the right corner of all sheets of the final plat, landscape plan, NPPO, and any other associated sheets.

3. The DSMR case number DS06-11 has expired. A new DSMR must be applied for and approved for the reduction of the street width. Revise note #16 on page 1 of 1 and note #18 on page 1 of 3. Add the date of approval and any revised conditions for the DSMR to both notes once the new DSMR has been approved.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961


C\planning\cdrc\finaplat\S08-071fpca
07/01/2008 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
07/01/2008 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor's Office
Mapping Department

DATE: June 30, 2008


RE: Assessor's Review and Comments Regarding Final Plat
S08-071 COLONIA SOLANA T141416


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.


COMMENTS: PLEASE MAKE THE FOLLOWING ADJUSTMENTS BY FINAL PLAT STAGE:

THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.




ROSANNA WERNER
07/02/2008 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S08-071 Colonial Solana 07/01/08

() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other –

CROSS REFERENCE: S05-250

NEIGHBORHOOD PLAN: El Encanto/Colonia Solana

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 7/1/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(XXXX) No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: drcorral 791-4505 DATE: 7/1/8
07/03/2008 ANDY VERA ENV SVCS REVIEW Approv-Cond 1. Adequate street frontage access for APC refuse and recycle curbside collection services for 4 residential/SFR. APC's may be placed out for service off Broadway Blvd.

2. If intend to place APC's off Rosa Maria Ct. (private street) then will be required to designate turnaround area as no parking for collection vehicle. Please clarify intent and note on DP.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
07/14/2008 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: July 14, 2008
CDRC/Zoning Manager
SUBJECT: Colonial Solana, 13246 E. Broadway Blvd.
Final Plat S08-071 (First Review)
T14S, R14E, Section 16

RESUBMITTAL REQUIRED: Final Plat.

The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a detailed response letter to the comments along with the corrected copies of the FP.
2. It appears that many of the dimensions do scale per the drawing. Re-check all dimensions for accuracy.
3. Change the "Non-vehicular access easement" to a "No vehicular access easement". The prior restricts pedestrian traffic not vehicular traffic.
4. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used:
" Title Report
" Special Warranty Deed
" Trust Agreement
" Amendment to Trust
" Agreement to Construct
Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review.
5. The title block of the plat must match the Subdivision Assurances verbatim.
6. A title block with the following information……………………..per D.S. 2-03.2.1.G.
7. Please re-label all common areas that may be used in a dual and/or single use capacity per D.S. 2-03.6.4.C. For example, a Ret./Det. Basin may also be used as a recreation facility or only as a drainage facility or drainage channel and this must be reflected on the Final Plat. A key note explaining the labels could be used in conjunction with the labels, ie.:
Common Area "A" - Streets
Common Area "B" - Drainage/Recreation Facilities
Common Area "C" - Recreation Facilities
Common Area "D" - Drainage Facilities
Common Area "E" - Landscaping
Per general note no. 16. common areas will be used.
8. Complete the case no. S08-071.
9. Correct the name of the clerk of the City of Tucson under the "Approval" block to the new city clerk.
10. Show visitor parking in a surveyable manner.
11. Show the distances between all survey monuments used.
12. Please submit a copy of the subdivision boundary closure calculations.

Grading Plan:

1. Cut or fill slopes require a 2' minimum setback from property line.
2. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/3246 E. Broadway Blvd FP
07/18/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 18, 2008

Kent A. Delph, P.E.
Grenier Engineering, Inc.
5517 East 5th Street
Tucson, Arizona 85711

Subject: S08-071 Colonial Solana Final Plat (formerly S05-250)

Dear Kent:

Your submittal of June 4, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Final Plat (ADA, Landscape, Wastewater, ESD, Engineering, DSD)

3 Copies Revised Landscape Plans (Landscape, Engineering, DSD)







Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 326-7508
fpresubmittal