Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S08-067
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - MINOR SUBD REVIEW

Plan Number - S08-067
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/09/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/24/2009 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Denied April 23, 2009

To: Peter Solonga
Oracle Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Eng. Manager
Development Review Division (Wastewater)

Subject: Nelson Mobile Home Estates II, Lots 1-11 and Common Areas "A, B, C & D"
Final Plat – 4th Submittal, S08-067


The drawings of the proposed Final Plat for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. Sheet 1: Remove General Note no. 13.

2. Sheet 1 Remove Permitting Note from the Final Plat and put this note on the Sewer Plan.

3. The comments made separately on the Sewer Plan drawing on April 23, 2009 must be taken care of before this Final Plat can be approved.

This office will require a revised set of bluelines, and a response letter, addressing these comments.

The fee for the next submittal will be $39.00. A check in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and the response letter.

If you have any questions regarding the above-mentioned comments, please contact me.
04/24/2009 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Denied >>> "Chandubhai Patel" <Chandubhai.Patel@dsd.pima.gov> 06/01/2009 9:50 AM >>>

Pete brought over the mylar for this project. It is now acceptable.

C.C. Patel, P.E.
Pima County DSD
05/04/2009 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207


JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: S08-067 NELSON HOMES II/REVISED MINOR SUBDIVISION REVIEW
DATE: May 1, 2009



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project pending the following:

Label common areas on all corresponding sheets.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
05/18/2009 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review
05/18/2009 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 18, 2009


Peter Salonga
Oracle Engineering Group
199 East Fort Lowell Road
Tucson, Arizona 85705

Subject: S08-067 Nelson Homes II Final Plat

Dear Peter:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * 81/2"X11" copy of plat
(1) * Check in the amount of $20.00 per plat page for recorded plat distribution made payable to the local print company that has access to Pima County Recorders on line platting system or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page and fees for consent(s) to dedicate, if applicable.
(2) Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). One original set and one copy of each.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

PRIOR TO SUBMITTING THE FINAL PLAT MYLARS TO THE CDRC OFFICE, THEY MUST BE REVIEWED AND APPROVED BY PIMA COUNTY WASTEWATER MANAGEMENT AND ADDRESSING. THE APPROVAL MUST BE IN WRITING (E-MAIL IS OKAY).

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager



All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 292-6144