Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S08-049
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Plan Number - S08-049
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/11/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/18/2008 JIM EGAN COT NON-DSD FIRE Denied Note 16 on Sheet 4 should read sprinklers are required on all lots. There is not sufficient turning and fire access on the site.
04/22/2008 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved ADOT has NO COMMENT on this project

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
04/22/2008 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
04/28/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 28 APRIL 2008
S08-049/SETTLERS TRACE
REVIEWED BY RON BROWN

ACCESSIBLE REVIEW
2006 IBC/ICC 117.1

DENIED: SEE COMMENTS BELOW

I. SHEET 2 OF 4:
A. DENOTE GOVERNING ACCESSIBILITY CODE; 2006 IBC/ICC 117.1 FOR PRIVATE PROPERTY
B. PROVIDE AND IDENTIFY ACCESSIBLE ROUTE THROUGHOUT SITE TO ALL BUILDING ENTRANCES AND EXITS AND PARKING FACILITIES AND TO NEAREST PUBLIC TRANSPORTATION POINT AS PER ICC 117.1, SECTION 402
1. SHOW LOCATION OF NEAREST PUBLIC TRANSPORTATION DROP OFF POINT.
C. NOTE 16: CHANGE "ADA" REFERENCE TO "2006 IBC/ICC 117.1"
II. SHEET 3 OF 4:
A. DENOTE RIGHT OF WAY ACCESSIBILITY STANDARDS; COT DOT STANDARD DETAIL 207 FOR CURB RAMPS AT DRIVE WAYS. SHOW CURB RAMPS AT 3RD STREET DRIVE ENTRANCE IN COMPLIANCE WITH COT DOT STANDARD DETAIL 207.
B. ALL INTERIOR SIDE WALK AND CURB RAMPS TO BE AS PER ICC 117.1, SECTIONS 405 AND 406
C. ACCESSIBLE PARKING:
1. ALL ACCESSIBLE PARKING SPACES, PRIVATE PROPERTY SIDE WALK RAMPS AND CURB RAMPS AND RAISED MARKED CROSSINGS TO MEET 2006 IBC/ICC 117.1 ACCESSIBLE STANDARDS, SECTION 406.
2. SHOW LOCATIONS OF ALL ACCESSIBLE PARKING SIGNS ON THE SITE DEVELOPMENT PLAN
D. SHOW SPOT GRADES THROUGHOUT ENTIRE ACCESSIBLE ROUTE TO COMPLY WITH ICC 117.1, SECTION 403.3
III. SHEET 4 OF 4:
A. DETAIL 2:
1. BOTTOM OF LARGER SIGN TO BE 7'-0" ABOVE FINISHED GRADE AS PER COT DOT STANDARDS. WHAT IS HEIGHT OF WALL? PROVIDE DETAIL SHOWING ALL SIGN COMPLIANCE.
2. "VAN ACCESSIBLE" SPACE TO BE 11' WIDE, ICC 117.1, SECTION 502.2
3. 5' WALK DIMENSION IS WITHOUT 6" WIDE CURB

END OF REVIEW
04/29/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Add the CDRC subdivision case number (S08-049) to all sheets of the landscape plan, native plant preservation plan, and tentative plat. DS 2-07.2.1.B

2. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Revise plan drawing so that each parking space falls within 40 feet of a canopy tree trunk.

3. Because the 3rd Street is fronted by a common area parking lot (see LUC Table 3.7.2-I under Specific Uses) rather than residential subdivision lots, a full 10-foot on-site landscape border and a 5-foot high screen is required. Revise plan drawings and coverage calculations to indicate the 10-foot landscape border and label screening location, height and type on the landscape plan. DS 2-07.2.2.A

4. Revise the landscape plan to include slope ratios and/or a cross section for the water harvesting basin.

5. Revise common area with recreational amenities to extend along the south property line per special exception condition #13. The basin falls largely outside of the common area but sheet 1 of 4 the "Water Harvesting/Recreation Area" as being within the common area. Revise the tentative plat as necssary to label the correct and full extent of the basin/rec. common area to demonstrate compliance with special exception condition #13, which requires that this rec. area extend along the south end of the property adjacent to both lots 6 and 7.
DS 10-01.4

6. Demonstrate compliance with special exception condition #11 regarding buffelgrass.

7. Dimension the minimum width and label the square footage measured from the inside of tree planters in the vehicle use area. An unpaved area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree.
LUC 3.7.2.3.A.1.c, DS 2-07.2.2.A.2.e

8. A minimum two (2) inch layer of organic or inorganic material (i.e., decomposed granite, rock mulch, or other material) will be used as ground cover under and around the vegetation in landscaped areas to help cool soil areas, reduce evaporation, and retard weed growth per DS 2-06.5.2.C. The area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, shall also be covered with an appropriate inorganic ground cover, such as decomposed granite. Revise the plans to clarify compliance. LUC 3.7.2.4.A.4
04/30/2008 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved CASE: Case: S08-049, SETTLERS TRACE: TENTATIVE PLAT REVIEW

COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS




Vehicle Trip Generation: Daily 105 PM Peak 11



Please call if you have questions or need additional information.





-------------------------------------------

KoSok Chae



177 N. Church Ave., Suite 405

Tucson, AZ 85701



520-792-1093 x487 [tel]

520-620-6981 [fax]

www.PAGnet.org
04/30/2008 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S08-049 SETTLERS TRACE/TENTATIVE PLAT
DATE: 4/29/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

All the subdivision information is not necessary on the Location Map. This may be deleted.
Add “a resubdivision of Lot 6….” to all Title Blocks.



es
05/01/2008 FRODRIG2 PIMA COUNTY WASTEWATER Denied April 30, 2008


To: DANIEL WHITE
PHYSICAL RESOURCE ENGINEERING, INC.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: SETTLER'S TRACE, LOTS 1-11 AND COMMON AREA "A"
Tent. Plat - 1st Submittal
S08-049


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

All Sheets: Show the jurisdiction’s case number, S08-049, in or near the title block of each sheet. This case number should be shown larger and bolder than any associated cross-reference numbers.

Sheet 2: Revise General Note #24 to read as follows:

THE ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet 2: Provide verification that existing HCS is 6” in diameter. TV inspection shows a combination of 6” and 4” HCS’s in the area.

Sheet 2: The private sewer on site must be designed to current County Standards and must be approved by PCRWRD director.


This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the tentative or preliminary plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.

If you have any questions regarding the above-mentioned comments, please contact me.
05/07/2008 ANDY STEUART COT NON-DSD REAL ESTATE Approved No comment.
05/07/2008 ED ABRIGO PIMA COUNTY ASSESSOR Approv-Cond Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)
FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: May 7, 2008


RE: Assessor’s Review and Comments Regarding Tentative Plat
S08-049 SETTLERS TRACE T141409


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: PLEASE MAKE THE FOLLOWING ADJUSTMENTS BY FINAL PLAT STAGE:
SHOW TIE TO THE SECTION WITH DIMS AND BEARINGS.

THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.




ROSANNA WERNER
05/08/2008 ANDY VERA ENV SVCS REVIEW Denied 1. This project will require one additonal single enclosure to accomodate for both refuse and recycle waste services for this residential development.

2. Clearly define the points for ingress/egress (i.e. concrete apron, vertical curb, curb radius etc.)t in order to determine adequate collection vehicle access and maneuverability.

Please provide corrections on resubmittal.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
05/09/2008 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved PARKS AND RECREATION DEPARTMENT COMMENTS

City of Tucson CDRC – Community Design Review Committee

CASE NAME & NUMBER: S08-049, Settlers Trace: TP
Submittal #: 1

COMMENTS DUE: 5/9/08 COMMENTS SENT: 5/8/08


Items reviewed: Tentative Plat and Landscape Plan

Related: SE-07-29 (RCP under 5 acres)
Alvernon-Broadway Area Plan

Parks and Recreation Department Staff has reviewed this proposal and offers the following comments:


APPROVED – No comments. No resubmittal required.



REVIEWER: Joanne Hershenhorn DATE: 5/8/08
























S:\PARKS_AND_RECREATION_DEPT\REVIEW_COMMENTS\CDRC_Cases\2008_ReviewsS08-049_Settlers_Trace.doc
05/12/2008 HEATHER THRALL ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: S08-045, Settlers Trace, RCP subdivision of 11 units
3830 E. 3rd Street, zoned R-3
Tentative Plat, 1st Review

TRANSMITTAL DATE: May 9, 2008

DUE DATE: May 09, 2008

COMMENTS:


1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is April 10, 2009.

2. This project was reviewed for compliance with the Land Use Code (LUC) and Development Standards (DS). Specifically, this project was reviewed for compliance with the criteria for a tentative plat content under DS 2-03.2.0, DS 2.10 for Residential Cluster Project Subdivision, and LUC 3.6.1 for RCP criteria.

3. Per DS 2-03.2.1.D, in the location map, please darken the street lines and names.

4. Per DS 2-03.2.1.G.2, I see the abbreviation provided for RCP, please list out "Residential Cluster Project" in the title block.

5. Per DS 2-03.2.2.A.1, provide both ownership and developer name, address, phone.

6. Per DS 2-03.2.2.B.1, Development Services has assigned subdivision case number S08-049 to this project. Please list this case number next to the title block.

7. Per DS 2-03.2.2.B.7, provide a note that the project shall comply with the requirements of LUC 3.6.1., Residential Cluster Projects.

8. Per DS 2-03.2.3.C, please show any existing/proposed easements.

9. Per DS 2-03.2.4.A, regarding lot lines:
A) Per the Assessor's, the overall lot and adjacent lot addressed 811 N. Alvernon recently did a lot combination/split process in 2007. It does not appear that this lot reconfiguration went through the city review process, as required per LUC 5.5.2.1 & 5.5.2.3. Is this lot change going to be represented on a separate drawing or on this plat?

10. Per DS 2-03.2.4.E, please advise if the property is going to be phased, and if so, show calculations and access to ensure each phase will be in compliance with LUC requirements.

11. Per LUC 3.6.1.2.C, a special exception is required for approval of an RCP under 5 acres in size. Staff had noted that the project has gone through the special exception review process under case SE-07-29. The various conditions of approval of SE -07-29 do apply to this project and are listed in the plat. Staff requests a written advisement of how each condition of the Special Exception will be met.

12. Per LUC 3.6.1.4.A.5, a minimum of 25% of the total number of units proposed must be barrier free. Declare which units in general note 27, for permitting and records.

13. Per LUC 3.6.1.4.A.D.regarding buildings and setbacks:
A) per LUC 3.6.1.4.A.D, perimeter setbacks for this project are "the greater of 10' or ¾ of the height of the exterior building wall", as is listed for this project. The setbacks on sheet 1, however, do not appear to demonstrate the minimum setback for the proposed 2 story structures. Please check.
B) clarify building wall height for 2nd story units, list as measured from grade to top of parapet.
C) ensure any single story porches are also keynoted with height.
D) call out how proposed building height of 21.5 feet is measured - needs to be from grade to roof height.
E) provide a minimum of 3' setback for ramada on rear common area
F) note that the model plans for the units - including elevations, must be provided to staff at the next review
G) note that the model plans must be approved by building code - and no openings and a 1 hour fire wall are going to be required for building walls on the side yard property line at a 0 setback abutting adjacent lot lines.
H) note that building codes must also approve the 0 setbacks proposed for the units

14. Per LUC 3.6.1.4.A.F, regarding parking:
A) provide wheel stop barriers in the top 2'6" of each parking space abutting sidewalks and property lines. Show in detail as well on sheet 4.
B) please advise what the darkened dashed line in center of the parking area represents. Note, if this is covered parking, it is not permitted per LUC 3.2.5.3.C - detached accessory structures are not permitted between the principal structure(s) and the street front lot line in residential zones.

15. Per LUC 3.6.1.4.G.2 and DS 2-08: regarding sidewalks:
A) Install wheel stops in parking spaces to ensure vehicle overhang does not reduce 4' minimum sidewalk clearance along west property line.
B) ensure physical separation between sidewalk and PAAL per DS 2-08.4.1
C) per DS 2-08.3.1., provide pedestrian access to dumpster

16. Per LUC 3.6.1.5.A, provide CCRs for maintenance of common areas

17. Regarding special exception requirements,
A) elevation drawings must be provided to show that condition 7 can be met.
B) include detail on how condition 10 can be met on the elevation.
C) show any outdoor lighting on the plan in accordance with condition 12
D) provide written responses explaining how all the conditions of the special exception can be met.

18. Further comments may be forthcoming, depending upon the responses provided. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951.

If you have any questions about this transmittal, please call (520) 791-5608.

C:\planning\cdrc\tentativeplat\S08-045 Settlers Trace tp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat, CC&R's and additional requested documents.
05/12/2008 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
05/14/2008 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S08-049 Settlers Trace

(X) Tentative Plat
() Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: SE-07-29

NEIGHBORHOOD PLAN: Alvernon-Broadway Area Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: May 9, 2008

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
(X) Tentative Plat
(X) Development Plan
() Landscape Plan
() Other

REVIEWER: msp 791-4505 DATE: 5/9/08

Department of Urban Planning and Design Comments
S08-049, Setters Trace: Tentative Plat Review
May9, 2008

Staff offers the following comments:

Tentative plat S08-049, submittal does not include information required for compliance with special exception condition number 6. Requires resubmittal to include material to comply with condition #6.

Tentative plat S08-049, submittal does not include information required for compliance with special exception condition number 7. Requires resubmittal to include material to comply with condition #7.

Tentative plat S08-049, submittal does not include adequate information required for compliance with special exception condition number 8. Requires resubmittal to include revised information with condition #8 (see sheet 4 of 4, detail #3).

Tentative plat S08-049, submittal does not include adequate information required for compliance with special exception condition number 9. Requires resubmittal to include revised information with condition #9 (see sheet 4 of 4, detail #3). Detail indicates a 5 feet, 4inch tall masonry wall.

Tentative plat S08-049, submittal does not include information required for compliance with special exception condition number 11. Requires resubmittal to include new language in the landscape plan, sheet 1 of 4. Please add as part of the “Planting Notes” a new note, as note number 9. Note #9 to be verbatim, as written in special exception condition # 11.
05/19/2008 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#196671 May 15, 2008



Physical Resource Engineering, Inc.
Attn: Daniel White
4655 N. Flowing Wells Rd
Tucson, Arizona 85705

Dear Mr. White:

SUBJECT: Settlers Trace
Lots 1-11
S08-049

Tucson Electric Power Company (TEP) has reviewed the tentative plat dated April 25, 2006. This Company is unable to approve the plat at this time.

There are existing electrical facilities within the boundaries of the development. The facilities along with the easement recording information must be shown on the plat prior to approval. If an existing easement is not found add a dimensioned easement by prescription and a general note that the facilities will be abandoned. All relocation costs will be billable to the developer. Please direct questions concerning easement(s) to Liza Castillo, Right-of-Way Agent in our Land Department at 520-917-8745.

TEP will provide a preliminary electrical design on the Approved Tentative Plat within fifteen (15) working days upon receipt of the plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Should you have any questions, please contact area designer Susie McCann at 917-8741.


Sincerely,



Henrietta Noriega
Office Specialist
Design/Build
hn
enclosures
cc: City of Tucson, (e-mail)
L. Tynes, S. McCann, Tucson Electric Power
05/28/2008 LOREN MAKUS ENGINEERING REVIEW Denied May 28, 2008

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division

SUBJECT: Settler's Trace Subdivision
Tentative Plat S08-049 (First Review)
T14S, R14E, Section 09

RESUBMITTAL REQUIRED: Tentative Plat

The Engineering Division has reviewed the Tentative Plat and Drainage Report, and we do not recommend approval at this time. The following review comments must be addressed:

1. The existing contours are too light to be discernable on the plans. Darken the contours sufficiently to be seen considering the shading used for concrete and asphalt. The streets and other details within the location map are also too light. Review all areas of all sheets to make sure that all drawing information is clearly legible.
2. Revise general note 22 on sheet 2 to remove the reference to the Major Streets and Routes overlay criteria. Since 3rd street is a local street remove all references to future right-of-way conditions.
3. Clarify whether the curb and sidewalk are existing or proposed. Proposed sidewalk must be at least 5 feet wide.
4. Show contours or spot elevations for areas within 100 feet of the site. Also include the locations and descriptions for structures including walls and fences within this 100 feet.
5. Provide a letter from the Department of Transportation granting permission to use the right-of-way for private landscaping.

Drainage Report Comments:
6. The drainage statement is approved for tentative plat purposes.

Submit a revised Tentative Plat with a detailed response letter detailing how each comment has been addressed.

If you have any questions, I can be reached at 520.837.4927 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
05/30/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 30, 2008

Daniel White
Physical Resources Engineering, Inc.
4655 North Flowing Wells Road
Tucson, Arizona 85705

Subject: S08-049 Settlers Trace Tentative Plat

Dear Dan:

Your submittal of April 11, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

11 Copies Revised Tentative Plat (Fire, ADA, Landscape, Addressing, Wastewater, ESD, Zoning, DUPD, TEP, Engineering, DSD)

5 Copies Revised Landscape Plan (Landscape, Zoning, DUPD, Engineering DSD)







Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax:
Tp-resubmittal