Plan Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Plan Number - S08-037
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/21/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/24/2008 | JIM EGAN | COT NON-DSD | FIRE | Denied | The minimum street width is 20 feet for fire access. No parking signs are required. See IFC Appendix D as amended. |
| 04/02/2008 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | April 1, 2008 To: Jean Armstrong Baker and Associates Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: Mosiac Court Lots 1-48 an RCP Project and Common Areas “A”,”B” and “C” Tentative Plat - 1st Submittal S08-037 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Regional Wastewater Reclamation Department (RWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. This project will be tributary to the Roger Road Wastewater Treatment Facility via the Aviation Corridor to Southeast. Obtain a letter from the RWRD's Development Services Section, written within the past 90 days, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at: http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf. The development plan for this project cannot be approved until a copy of this letter has been received by this office. All Sheets: Show the jurisdiction’s case number, S08-037, in or near the title block of each sheet. This case number should be shown larger and bolder than any associated cross-reference numbers. Sheet 2: Revise General Note #19 to read as follows: THE ON-SITE SANITARY SEWERS, EXCEPT PUBLIC SEWERS WITHIN PUBLIC SEWER EASEMENTS OR RIGHTS-OF-WAY, WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT. Sheet 2: Demonstrate that the new invert for the connection to Ex MH#4955 will be in accordance with WWM-301 or variance. Sheet 2: Show Ex MH #4442-01 just north of #4955-01. Sheet 2: Terminal reach #5 is to short to be of value. The terminal reach should serve Lots 1-9 to be anywhere close to self cleaning. Sheet 2: Almost all of the sewers shown on this sheet are too shallow to be constructed of PVC Sheet 2: Show that adequate access will be provided to existing MH#4955-01 to 03 via sections of depressed or wedge curbing. Sheet 2: Parking is not an acceptable use within the public sewer easements. Sheet 3: The call out information for sewer segment #5 is not shown. Sheet 3: The terminal reaches must be @ 1%. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above-mentioned comments, please contact me. |
| 04/02/2008 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | ADOT has NO COMMENT on this Project. -------------------------------------------------------- Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments. |
| 04/02/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S08-037 MOSAIC COURT/TENTATIVE PLAT DATE: 4/02/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: ON FINAL PLAT: 1.) Label approved interior street names on Final Plat. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** es |
| 04/03/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. The street landscape border along Stella Road (designated Major Street & Route) dimensions to only 8 feet on the drawing and is listed as only 5 feet wide in the landscape border table on sheet L4. Revise to be correct. Dimension all landscape borders on the landcape plan drawing. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee, up to five (5) feet of the required ten (10) foot width be placed within the adjacent Major Streets and Routes (MS&R) right-of-way area on MS&R streets. LUC 3.7.2.4.A.3 2. Add the CDRC subdivision case number (S08-037) and the rezoning case number (C9-78-63) to the lower right hand corner of all sheets of the tentative plat and landscape plan. 3. Revise the landscape plan to show the locations and note the height and materials used to construct any proposed or required screen walls, including the required 5-foot screen wall to screen the proposed vehicle use from adjacent O-3 zoned properties near the south and east property lines of subdivision "Area 1" and near the north property line of "Area 2". DS 2-07.A.3, LUC Table 3.7.2-I 4. The landscape borders shall be recorded as common area and maintained by the homeowners association (HOA). The subdivision CC&Rs and shall reference the maintenance standards in Sec. 3.7.6. LUC 3.7.2.4.A.1.c. 5. All disturbed areas including adjacent rights-of-way shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment within the MS&R right of way. 6. Any required storm water detention/retention basins shall be landscaped to enhance the natural configuration of the basin. Design criteria are set forth in Development Standard 10-01.0. LUC 3.7.4.3.A Organic ground cover is recommended and overall, inert groundcovers alone should not comprise over 35% of the total basin area. Refer to guidelines in DS 10-01, pages 90-96. 7. One canopy tree must be provided for every thirty-three (33) linear feet of the landscape borders. If this cannot be achieved then an equivalent number of trees must be planted elsewhere on the site between the building(s) and the property lines. 8. All lettering and dimensions shall be the equivalent of twelve point (0.12") or greater in size. Revise all text on sheet L1, which does not meet this minimum requirement. |
| 04/04/2008 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 04/07/2008 | FRODRIG2 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approv-Cond | To Whom it May Concern: The attached PDF contains the estimated trip generation information for the project S08-037. Summary: CASE: S08-037 COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS. However, further traffic impact and traffic mitigation study is advised. Vehicle Trip Generation: Daily: 459 PM Peak: 48 Please do not hesitate to contact me if you have any questions, Sincerely, Sandy Sandra C. Holland Senior Statistical/ Research Analyst Pima Association of Governments 177 N. Church Ave, Suite 405 Tucson AZ 85701 Tel: 520 792 1093 X462 Fax: 520 620 6981 |
| 04/11/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Denied | April 11, 2008 ACTIVITY NUMBER: S08-037 PROJECT NAME: Mosaic Court PROJECT ADDRESS: 3315 S Wilmot Rd PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering does not recommend approval of the Tentative Plat; therefore a revised Tentative Plat is required for re-submittal. The following items must be revised or added to the plat. 1. Include a response letter with the next submittal that states how all comments have been addressed. 2. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 3. Add a general note to read "All non-signalized intersection street names must have E-W block number addresses for E-W roadways and N-S block number addresses for N-S roadways." 4. Jogs of less than 150' in local alignment are not acceptable per (DS 3-01.6.3). Align the western PAAL along Stella with Vaughn Drive on the north side of Stella RD. If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
| 04/17/2008 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | -Request this plat be identified as a Sub-Plat of Wilmot Vista, Lots 1-101, C.A. "A" & "B" & Blks. 1 & 2. -Request confirmation if C,C&R's, Dkt. 8976 Pg. 806, will remain binding concerning Blocks 1 & 2, Wilmot vista Sub. and particuliary to the Detention/Retention Basin in C.A. "A". |
| 04/18/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Mosaic Court, Lots 1 - 48 - Northwest Corner of Wilmot Rd. & Stella Rd. Tentative Plat S08-037 (1st Review) TRANSMITTAL DATE: April 18, 2008 DUE DATE: April 18, 2008 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is March 20, 3009. 2. D.S. 2-03.2.2.B.1 Place the S08-037 subdivision case number in the lower right corner of the plat next to the title block. 3. D.S. 2-03.2.2.B.5 Under General Note 6 change the use to "FAMILY DWELLING, RCP 8 & 9, SUBJECT TO LUC SEC. 3.6.1". 4. D.S. 2-03.2.2.B.7 Add a general note to the plan stating "THIS PLAT IS DESIGNED TO MEET THE OVERLAY ZONE CRITERIA: LUC, SEC 2.8.3 MAJOR STREETS AND ROUTES (MS&R) SETBACK ZONE. 5. D.S. 2-03.2.2.D.1.b The vehicle circulation, PAAL's, shown on the plan are required to be streets. This said revise General Notes 14 & 15 to reflect the miles of public or private streets. 6. D.S. 2-03.2.4.G Per LUC Section 3.6.1.4.F.3 the provided parking area access lanes (PAAL's) are required to be streets. The provided PAAL sections do not meet the requirements for a street section, see D.S. 3-01. A variance or Development Standards Modification Request (DSMR) may be required. 7. D.S. 2-03.2.4.G Per LUC Table 3.3.7.I the minimum aisle width for access to ninety (90) degree parking is twenty-four (24) feet. This said the proposed eighteen (18) foot PAAL along the south end of both developments does not meet the twenty-four (24) foot requirement. 8. D.S. 2-03.2.4.G A barrier-free access route, sidewalk is required on both sides of the proposed streets. 9. D.S. 2-03.2.4.G Fully dimension the proposed visitors parking. 10. D.S. 2-03.2.4.J If applicable show all proposed easements (utility, sewer, drainage, access, etc.) dimension and label as to their purposes and whether they will be public or private. 11. D.S. 2-03.2.4.M Provide a typical lot setback detail. Based on the number of lots in each area of the subdivision it does not appear that you meet the ADT of 140 or less. This said the proposed interior street setbacks listed are not correct. Also if the ADT of 140 or less is allowed lots 4 & 30 do not appear to meet the setback requirements. 12. As this proposed RCP is two separate non-contiguous developments, less than 5 acres each the following applies. Per LUC Section 3.6.1.2.C RCPs for sites that are five (5) acres or less shall be reviewed and approved through the Zoning Examiner Full Notice Procedure, Development Compliance Code, Sec. 23A-50 and 23A-53. The Zoning Examiner Full Notice Procedure must be completed and approved prior to approval of this tentative plat. 13. LUC 3.6.1.4.A.4 Designate the specific lots that will provide the required barrier-free accessibility for the elderly and physically disabled. 14. LUC 3.6.1.5 Provide the required documentation that addresses the requirements of LUC 3.6.1.5 Management of Common Properties. 15. Depending on how the above comments are addressed additional comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\cdrc\tentativeplat\S08-037tp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat, site plan and additional requested documents. |
| 04/21/2008 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. Not adequate turning radii for collection vehicle throughout development. Require a minimum 36 ft inside and 50 ft outside turning radii. DS 6-01.0 figure 1. 2. Appears to be adequate street frontage access for APC refuse and recycle curbside collection services. APC's must be placed on sidewalk or buffer area between sidewalk and curb. APC's may not be placed in street for collection. Please provide corrections on resubmittal. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 04/24/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S08-037 Mosaic Court 04/22/08 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-78-63 NEIGHBORHOOD PLAN: South Pantano Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: April 18, 2008 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X*) Resubmittal Required: (X) Tentative Plat () Development Plan (X) Landscape Plan (X) REQUIRES A SPECIAL EXCEPTION APPROVAL REVIEWER: MSP 791-4505 DATE: 4/18/08 Department of Urban Planning and Design Comments S08-037 Mosaic Court Tentative Plat Review April 18, 2008 Staff offers the following comments. A discussion with Patricia Gehlen of the Department of Development Services, determined the following information; tentative plat S08-037 requires a special exception because it is proposed as an RCP and consist of two parcels which are not adjoined or abut each other, and each parcel is less than five acres in size. Please review submittal requirements on RCP projects of less than five acres in size and include this information at the time of the special exception process. In addition DUPD staff is requiring the tentative plat to be revised to include the following requirements: 1.a, As an RCP project, the proposed tentative plat shall comply with the South Pantano Area Plan policy requirements. This includes the requirements active and passive recreational amenities. However, based on the small size of each parcel and the fact that a small city park is located at mid-block, east on Stella Road, staff will consider on-site “passive” recreational amenities only on each parcel. Staff’s support will depend on the applicant’s proposal as to where and what amenities will be located at each parcel. As an example, amenities may include but not limited to pedestrian trails/paths, trees, benches, table(s), trash container(s), tot lot, turf area etc, and other passive amenities within common areas. These amenities shall be centrally located with high visibility in mind (Safe by Design Criteria). 1.b To reduce the heat island effect along pedestrian paths (sidewalks), please include a native and thornless canopy tree, within the front yard of every other lot, on both sides of every street within the subdivision. Trees will be located up toward the front property line of the lot so as to create a shady corridor along these streets when trees mature. |
| 04/28/2008 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#196005 April 25, 2008 Baker & Associates Engineering Attn: Jean V. Armstrong 3651 E. Sunrise Dr. # 225 Tucson, AZ 85718 Dear Jean Armstrong: SUBJECT: MOSAIC COURT Lots 1 Thru 48 S08-037 Tucson Electric Power Company (TEP) has no objection to the preliminary plat submitted for review April 9, 2008. The preliminary point where TEP will provide possible feeds are from Block 1 –Transformer EST-52 & Poles 129 & 258; Block 2 – Poles 240 and 241. This is a very tight subdivision with small lots. Hypothetical equipment placement on this tentative plat have been placed. Due to lot size and service size, the equipment could be moved from the hypothetical locations. When the customer requests a layout on the approved tentative plat, our Designer will place permanent facilities for said project. All additional costs will be paid by the developer. The Designer will need at least 6 to 8 weeks for the design and layout of this subdivision. Enclosed is a copy of TEP’s facility map showing the approximate location and unit numbers of the existing facilities. Also enclosed is a copy of the tentative plat showing where TEP will be placing the aboveground equipment for this subdivision. This is not a preliminary design. TEP has provided this drawing to show where the proposed locations are for transformers and pedestals. TEP will provide a preliminary electrical design on the Approved Tentative Plat within fifteen (15) working days upon receipt of the plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Also, submit the AutoCAD version of the plat on a CD or email to HNoriega@tep.com. Should you have any questions, please contact Rich Harrington at (520) 917-8726. Any technical questions or concerns should be directed to the Designer, Marcus Hayes at 917-8705. Sincerely, Henrietta Noriega Office Specialist - Design/Build hn Enclosures cc: City of Tucson, (email) S. Thu, Developer (letter only) |
| 04/28/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | PARKS AND RECREATION DEPARTMENT COMMENTS City of Tucson CDRC – Community Design Review Committee CASE NAME & NUMBER: S08-037, Mosaic Court TP Submittal #: 1 COMMENTS DUE: 4/18/08 COMMENTS SENT: 4/24/08 Items reviewed: Tentative Plat and Landscape Plan Related: land use plan(s) – South Pantano Area Plan Parks and Recreation Department Staff has reviewed this proposal and offers the following comments: APPROVED - No comments. No submittal required. REVIEWED BY: Joanne Hershenhorn DATE: 4/24/08 S:\PARKS_AND_RECREATION_DEPT\REVIEW_COMMENTS\CDRC_Cases\2008_ReviewsS08-037_Mosaic_Court_TP.doc |
| 05/05/2008 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: April 28, 2008 RE: Assessor’s Review and Comments Regarding Tentative Plat S08-037 MOSAIC COURT T141530 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: PLEASE MAKE THE FOLLOWING ADJUSTMENTS BY FINAL PLAT STAGE: THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390 NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. ROSANNA WERNER |
| 05/16/2008 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: May 16, 2008 SUBJECT: Mosiac Court- Tentative Plat Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 3315 S Wilmot Road, T14S R15E Sec30 Ward 4 REVIEWERS: Jason Green, CFM ACTIVITY: S08-037 SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted Tentative Plat, Drainage Report (Baker and Associates Engineering, Inc., 10MAR08) and a copy of the Title Report. The Drainage Report was reviewed for Tentative Plat purposes only. The Tentative Plat is not approved at this time. The following items need to be addressed: TENTATIVE PLAT: 1) DS Sec.2-03.2.2.B.1: The correct Tentative Plat number (S08-037) may be added to the lower right hand corner of the plans where indicated by "#." 2) DS Sec.2-03.2.2.B.7: Provide a General Note on the Tentative Plat that references all special overlay zones that are applicable to this plat, specifically state that the plat is designed to meet the overlay zone criteria for Major Streets and Routes (MS&R) Setback Zone, LUC Sec.2.8.3. 3) DS Sec.2-03.2.2.D.b: Revise the Tentative Plat and General Notes #14 and 15 to show the correct miles of either private or public streets that is required for this development. Parking Area Access Lanes (PAALs) are not acceptable in residential subdivisions. All vehicle access must be provided by either a public or a private street, refer to DS Sec.3-01 for street development criteria. 4) DS Sec.2-03.2.3.A: Revise the Tentative Plat to show all benchmark locations, proposed location of and method of tie to the permanent survey monuments or nearest section corner, specifically show the survey monument for the Basis of Bearing for the west side at the intersection of Wilmot and Stella. 5) DS Sec.2-03.2.3.C: Revise the Tentative Plat to reflect all existing easements with recordation information, location, widths, and purpose. Specifically Item #6 on Schedule B of the Title Report could not be located on the plans, either clarify the location or add to the Tentative Plat. 6) DS Sec.2-03.2.3.E: Revise the Tentative Plat to assure that all of the existing utilities are shown. Clearly show and label existing water lines, gas lines, electric lines, telephone lines/poles, and existing/proposed sewer lines. For sanitary sewers include the pipe diameter, the invert and rim elevation for all manholes and clean outs. 7) DS Sec.2-03.2.3.G: Revise the Tentative Plat to show all existing storm drainage facilities that are located adjacent to both subject parcels, provide all referenced improvement plan numbers along with the location of all storm drains, grates, culverts, etc. 8) DS Sec.2-03.2.4.C: Revise the Tentative Plat and the Title Block to remove the PAAL description from Common Area "A", the common area must reflect either private or public streets that are required for this project. 9) DS Sec.2-03.2.4.C: Revise the Tentative Plat to clearly enclose with a solid line each Common Area, Private Street, etc that will have separate restrictions or a separate homeowners' association. Common Area "C" must be clear on the Tentative Plat for the Retention Basins and the private streets must be added in place of the proposed PAALs. Verify that CC&R's are submitted and that they provide for maintenance responsibility for all common areas and required private streets. 10) DS Sec.2-03.2.4.E: Revise the Tentative Plat to verify if the project is to be phased. Show phase lines on the drawing, if applicable (since this project consists of 2 non-contiguous parcels it is unclear if they will both be developed at the same time or in phases, clarify). 11) DS Sec.2-03.2.4.F: Revise the Tentative Plat so that it is designed in accordance with Street Development Standard 3-01.0. The following items need to be revised or added to the proposed Tentative Plat: a) Label the required 25-foot radii at the access points along both MS&R Roadways. The curbs should be constructed at the edge of pavement, which must also be depicted on the site plan. Curb returns must be constructed entirely within the subject parcel. Refer to DS Sec.3-01.3.2.C and the Transportation Access Management Guidelines for street development standards. For further information contact the Tucson Department of Transportation, Jose Ortiz, P.E. at 837-6730. b) Revise the Tentative Plat to show the correct Sight Visibility triangles (SVT), with dimensions for the access points off of Wilmot Road (Arterial) and Stella Avenue (Collector) per DS Sec.3-01.5.0. Revise the landscape plan to reflect the sight visibility triangles shown on the Tentative Plat. 12) DS Sec.2-03.2.4.F: Revise the Tentative Plat to show either public or private roadway design criteria. Per LUC Sec.3.6.1.4.F.3 the PAALs are required to be either a public or private street, revise. The provided PAAL sections do not meet the requirements for a street section; refer to DS Sec.3-01 for all criteria and minimum requirements for the required street sections. A variance or Development Standards Modification Request (DSMR) may be required. 13) DS Sec.2-03.2.4.J: Clarify the proposed 7.5-foot Greencourt easement that is shown on the Tentative Plat. Provide recordation information or state easement is to be dedicated by Final Plat. Is this easement proposed to address pedestrian circulation that is required along all frontages of the required streets, clarify? 14) DS Sec.2-03.2.4.J: Provide easements for all utilities with recordation information or provide the description for each utility in respective Common Areas, verify that the CCRs match the Common Area descriptions. Easements are to be dimensioned and labeled as to whether they are public or private. 15) DS Sec.2-03.2.4.K: Either provide separately, or show a conceptual grading plan on the Tentative Plat, with the resubmittal of the Tentative Plat and Drainage Report. The conceptual grading plan is required on this project due to the proposed retention basin and required roadway sections. A Geotechnical Report is required to discuss the suitability of the project site. The soils report needs to discuss suitability and feasibility of the project. Besides description of existing soil constraints for the site, structural design recommendations, pavement design section, and other typical geotechnical data is needed. The soils report shall provide identification / assessment of any potentially hazardous geotechnical areas, provide proposed recommendations for setbacks from building to drainage areas include minimum distance from foundations to retention basin, and provide infiltration test results. The geotechnical report shall specifically address all criteria listed in this section. See last sentence of this section for items 6 (c) & (d) regarding hydro-collapsing soils and 30-foot test boring for basin design. Recommendations need to be incorporated into the conceptual grading plan, Tentative Plat, and Drainage Report. 16) DS Sec.2-03.2.4.L: Revise the Tentative Plat, in conjunction with the submitted Drainage Report, to reflect the following information. For additional information regarding drainage standards, see the City of Tucson Standards Manual for Drainage Design and Floodplain Management. a) Provide spot elevations at intervals along both proposed basin bottoms to show slope percentage. The bottom of basin slope must be 0.5% or greater to prevent accumulation of standing water and mosquito infestation. Both basins must provide a low flow bleeder pipe to prevent standing water per Division directive. b) Revise the proposed retention basin on the Tentative Plat and drainage exhibit to meet the requirements within DS Sec.10-01.4.3.1. All basins must be designed with curvilinear shapes or with a minimum 10-foot radius curves at all 90 degree bends. c) Provide proposed spot elevations at different points on each lot for reference to future grading and site drainage. d) Revise the Tentative Plat and Hydrology Report to show that the 10-year flow from the basin outlet is contained under all proposed sidewalks. Provide clear details in plan view for both basin inlets, outlets, erosion protection and for any proposed scuppers under the pedestrian circulation. 17) DS Sec.11-01.9: Revise the Tentative Plat to provide the required 2-feet setback from all property boundaries to the proposed limits of grading, fill slopes, retention basin, block wall and associated erosion protection. The plan view on the Tentative Plat shows that the limits of grading encroach within the required 2-feet setback. Provide sufficient room to allow for the 2-feet setback from property lines to top of fill slopes and associated erosion protection. 18) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications: a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html / b) http://www.dot.ci.tucson.az.us/engineering/pia.php c) Or contact Thad Harvison at 837-6592 for all additional questions regarding r-o-w. DRAINAGE REPORT: 19) DS Sec.10-01.4.3.1: The proposed basins do not satisfy the requirements for multi-use basin design. Provide natural looking design for the basins per DS Sec 10-01.1.1.2, to show that the proposed design provides a detention/retention facility that has multi-use facilities and is visually appealing. All basins must be designed with curvilinear shapes or with a minimum 10-foot radius curves at all 90 degree bends. 20) DS Sec.10-02.11.4.4.2: Revise Drainage Report to provide calculations for riprap sizing (D50) and provide filter fabric specifications for all proposed details that are sown on the developed exhibit, Figure 2. Revise the cross sections and general details to provide all spot elevations, low flow bleeder pipes, riprap specifications along with method of placement, filter fabric specification, etc. for all proposed drainage improvements. 21) Verify that the recommendations in the required geotechnical report have been addressed in the Drainage Report, basin design and basin location. GEOTECHICAL REPORT: 22) DS Sec.10-01.III.3.5.1.3.a, 10-02.14.2.6: Provide a Geotechnical Report Evaluation that addresses the following: a) Soils report should provide conformance with DS Sec.10-02.14.2.6 regarding 30-foot boring for basin, and provide a discussion of the potential for hydro-collapsible soils and any recommendation for setbacks from the buildings to both proposed retention basins. b) The soils report shall provide identification / assessment of any potentially hazardous geotechnical areas, and state any geotechnical recommendations and whether there are special provisions for the soil preparation for this development. c) Provide slope stability recommendations for any proposed constructed slopes. d) Provide pavement and asphalt recommendations for the required streets. e) Provide percolation rates for retention basin for 5-year threshold retention. GRADING PLAN: 23) DS Sec.11-01.2.1: For future references a grading permit application will be required for this project. A grading permit may not be issued prior to Tentative Plat approval. 24) Please ensure the grading plan is consistent with the Tentative Plat, Drainage Report, and Geotechnical Report. Grading standards may be accessed at http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf. 25) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with grading plan submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html. GENERAL COMMENTS: Provide a revised Tentative Plat, a revised Drainage Report, and a Geotechnical Report at re-submittal. The revised Tentative Plat, Drainage Report, and Geotechnical Report must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the Tentative Plat, Drainage Report, and Geotechnical Report. If you have any questions, I can be reached at (520) 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 05/19/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 19, 2008 Jean V. Armstrong Baker & Associates Engineering, Inc. 3561 East Sunrise Drive, #225 Tucson, Arizona 85718 Subject: S08-037 Mosaic Court Tentative Plat Dear Jean: Your submittal of March 21, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 10 Copies Revised Tentative Plat (Fire, Wastewater, Landscape, Traffic, Real Estate, Zoning, ESD, DUPD, Engineering, DSD) 5 Copies Revised Landscape Plan (Landscape, Zoning, DUPD, Engineering, DSD) 2 Copies Revised Drainage Report (Engineering, DSD) 2 Copies Geotechnical Report (Engineering, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 318-1930 Tp-resubmittal |