Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S08-034
Parcel: Unknown

Address:
3644 E GLENN ST

Review Status: Completed

Review Details: RESUBMITTAL- RECORD OF SURVEY

Plan Number - S08-034
Review Name: RESUBMITTAL- RECORD OF SURVEY
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/26/2008 CDRC1 PIMA COUNTY WASTEWATER Approved September 26, 2008

To: Geoffrey Brimhall, R.L.S.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter , Sr. Civil Eng. Assistant
Development Review Division
Pima County Development Services Department

Subject: Record of Survey
3644 E Glenn Rd 4 Lots, 2nd submittal
S08-034

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the Record of Survey as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please do not hesitate to contact me at 520-740-6579.





CC: Project file
10/03/2008 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: S08-034 GLENN STREET RECORD OF SURVEY/REVISED RECORD OF SURVEY
DATE: 10/02/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

On Location Map D-Change Acers to Acres and E- Change Gleen to Glenn.
Correct Portion S2 NW4 NE4 NW4 Section 33-13-14 surrounding parcels.
Recorded deeds with legal descriptions will need to be submitted in order to address additional lots.






es
10/03/2008 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207


JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: S08-034 GLENN STREET RECORD OF SURVEY/REVISED RECORD OF SURVEY
DATE: 1/27/09



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

Note: Recorded deeds with legal descriptions will need to be submitted prior to addressing.
10/08/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
10/08/2008 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: Patricia Gehlen DATE: October 8, 2008
CDRC/Zoning Manager

SUBJECT: 3644 E. Glenn Street, Record of Survey
Final Plat S08-034 (Secon Review)
T14S, R15E, Section 14

RESUBMITTAL REQUIRED: Mylar of Record of Survey.

Record of Survey:

1. Please include a response letter to the comments along with the corrected copies of the ROS.
2. The ROS cannot be approved prior to the recordation of all proposed easements on the survey.
3. Dedication of the 64' 1/2 Right-of-Way shall be required and shown on the ROS.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/3644 E. Glenn St._ROS 2
10/10/2008 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: October 10, 2008

TO: DSD_CDRC@ tucsonaz.gov

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov


SUBJECT: S08-0034 Glenn Street Record of Survey: Resubmittal(9-25-08)



Staff has no comments.
10/13/2008 ANDY STEUART COT NON-DSD REAL ESTATE Approv-Cond Request Dkt. & Pg. for conveyance of 2' along Glenn St. be annotated prior acceptance of Record of Survey.
10/13/2008 JIM EGAN COT NON-DSD FIRE Approved
10/17/2008 TERRY STEVENS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S08-034
Glenn Street Record of Survey
Record of Survey

TRANSMITTAL: 10/17/2008

DUE DATE: 4/15/08

COMMENTS:

1. The Zoning Review Section approves the record of survey for this subdivision, subject to the following changes on the executed record of survey plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised record of survey plat to verify that those changes do not affect any zoning requirements.

2. Change the "future dedication" to "dedication of right of way per docket____page_____." Include recording information. Provide on both sheets.

3. Provide recording docket and page information for all easements (individually) on both sheets.

4. Provide location of all proposed utilities to each structure. (gas, water and electrical) Indicate clearly the location of all utilities on the supplemental sheet.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961


TLS C:\planning\cdrc\ros\S08-034ros-ca.doc
10/22/2008 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review
10/22/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES


October 22, 2008

Daniel White
Physical Resource Engineering, Inc.
P.O. Box 36985
Tucson, Arizona 85740

Subject: S08-034 Glenn Street Record of Survey

Dear Daniel:


The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off.

(1) Executed Record of Survey Double Matte Oce or Photo Mylar.
(2) Check made to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee for recording purposes.
(3) Check made to "Reproductions, Inc." in the amount of $2.00 per plat page for CDRC file copy.

The CDRC office will then take your stamped and approved Record of Survey mylar to the Pima County Recorder's Office for recording and after recording a copy will be made for the CDRC file. You will be notified when this has been done to pick up your recorded Record of Survey mylar from the CDRC office and take it to the Pima County Addressing office at 201 North Stone Avenue (across from the CDRC office) for addressing of the site.

The mylars must be reviewed and approved by Pima County Addressing prior to submittal to the CDRC office. The approval must be in writing (e-mail is okay).

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.cityoftucson.org/dsd

Via fax 690-1769