Plan Review Detail
Review Status: Completed
Review Details: RECORD OF SURVEY REVIEW
Plan Number - S08-033
Review Name: RECORD OF SURVEY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/12/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/14/2008 | JIM EGAN | COT NON-DSD | FIRE | Denied | A Docket & Page needs to be provided for the Ingress-Egress Easement concerning Parcel A access to Parcel B |
| 03/14/2008 | JIM EGAN | COT NON-DSD | FIRE | Denied | A Docket/Page needs to be provided concerning Ingress-Egress Easment for Parcel A access through Parcel B. |
| 03/14/2008 | JIM EGAN | COT NON-DSD | FIRE | Denied | A docket/page need to be provided on the Ingress-Egress Easement for Parcel A to have access to Parcel B. |
| 03/14/2008 | JIM EGAN | COT NON-DSD | FIRE | Denied | The condo's in the rear of the property are over 440 feet from the nearest fire hydrant. The maximum is 300 for condominiums. See IFC 508.1 as amended. Has the rear 40 feet of the property been split already? It is needed for fire access. These corrections were addressed in S07-190, 2nd review, but the corrections do not show up in this submittal. |
| 03/18/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | A Docket & Page needs to be provided for the Ingress-Egress Easement concerning Parcel A access to Parcel B |
| 03/18/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | A Docket/Page needs to be provided concerning Ingress-Egress Easment for Parcel A access through Parcel B. |
| 03/18/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | A docket/page need to be provided on the Ingress-Egress Easement for Parcel A to have access to Parcel B. |
| 03/19/2008 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | ADOT has NO COMMENT on the record of survey -------------------------------------------------------- Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments. |
| 03/20/2008 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 03/21/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | Add the CDRC case number (S08-033) to the lower right hand corner of each Record of Survey sheet per DS 2-03. |
| 03/21/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S08-033 1128 BLACKLIDGE RECORD OF SURVEY DATE: 3/21/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Move Title Block to the lower right hand corner. Change Parcels A-C to Lots 1-3 and include in Title Block. Delete tax codes, owner information and addresses of all adjacent parcels. Spell out all street suffixes except on Location Map. es |
| 03/21/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | A Docket & Page needs to be provided for the Ingress-Egress Easement concerning Parcel A access to Parcel B |
| 03/21/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | A Docket/Page needs to be provided concerning Ingress-Egress Easment for Parcel A access through Parcel B. |
| 03/21/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | A docket/page need to be provided on the Ingress-Egress Easement for Parcel A to have access to Parcel B. |
| 03/21/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S08-033 Blacklidge Record of Survey 03/21/08 ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (XXXX) Other - Record of Survey CROSS REFERENCE: NEIGHBORHOOD PLAN: Cragin Keeling GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 04/09/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment (XXXX) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: drcorral 791-4505 DATE: 03/21/08 |
| 03/28/2008 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#195220 March 27, 2008 Oracle Engineering Group Attn: Peter Salonga 199 E Ft. Lowell Tucson, Arizona 85705 Dear Mr. Salonga: SUBJECT: Blacklidge Record of Survey S08-033 Tucson Electric Power Company has reviewed and approved the development plan submitted March 13, 2008. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Should you have any technical questions, please call the area Field Technician, Josh Necas at (520) 917-8759. Sincerely, Elizabeth Miranda Office Support Specialist Design/Build lm Enclosures cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email) J. Necas, Tucson Electric Power |
| 04/03/2008 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: April 3, 2008 SUBJECT: 1128 Blacklidge Record of Survey- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 1128 Blacklidge Dr, T13S R14E Sec31 Ward 3 REVIEWERS: Jason Green, CFM ACTIVITY: S08-033 SUMMARY: Engineering Division of Development Services Department has received and reviewed the Record of Survey package. The Record of Survey is not approved at this time. Please address the following comments: RECORD OF SURVEY COMMENTS: 1) DS Sec.2-03.11.1.C: Provide documentation showing that the required 5-foot wide sidewalk with curb has been installed or is existing along Blacklidge Drive; documentation can be in the form of a finalized right-of-way use permit or clear photographic documentation. Verification that the 5-foot sidewalk is installed is required prior to Record of Survey approval. 2) DS Sec.2-03.11.7.B: Revise the Record of Survey Sheet to include a 2-inch margin on the left side and ½-inch margins on all remaining sides. 3) DS Sec.2-03.11.7.D.2: Revise the project location map to identify conditions within the square mile area, such as major watercourses (Wilson Avenue Wash, Mountain Avenue Wash, etc.). 4) DS Sec.2-03.11.7.D.3: Provide the Section, Township and Range section corners on the project location map. 5) DS Sec.2-03.11.7.E: Revise the Record of Survey to add the words "Book ______ Page ____" in both the upper and lower right corners outside the margin line. 6) DS Sec.2-03.11.7.F: Provide a title block for the Record of Survey with the following information, preferably in the lower right corner of the Record of Survey: 1) The first line of the title block must read "RECORD OF SURVEY"; 2) Provide the proposed name of the Land Survey Exception; 3) Provide the number of proposed lots; 4) include a brief legal description. 7) DS Sec.2-03-11.8.A.1: Revise the Record of Survey to list the name, addresses, and telephone numbers of the primary owner(s) of the site. 8) DS Sec.2-03.11.8.B.1: Revise the Record of Survey to indicate the subdivision cases number assigned (S08-033) it may be added to the lower right hand corner of the plan. 9) DS Sec.2-03.11.8.B.3: Provide the following note on the first sheet of the Record of Survey; "The Number of lots is ___." Fill in the lot number. 10) DS Sec.2-03.11.8.B.4: Provide the following note on the first sheet of the Record of Survey; "The gross area of the existing parcel is____." 11) DS Sec.2-03.11.8.B.5: Provide the following note on the first sheet of the Record of Survey; "There will be no further division of lots without the expressed approval of the City of Tucson." 12) DS Sec.2-03.11.8.C.1: Provide the following note on the first sheet of the Record of Survey; "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." 13) DS Sec.2-03.11.9.A: Revise the Record of Survey to provide the following paragraph per this section, "I hereby certify that the boundary survey as shown on this Record of Survey was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this Record of Survey was prepared under my direction." The last statement is missing from the Record of Survey. 14) DS Sec.2-03.11.9.B: Provide the following language for the dedication paragraph to read the following statement from the Development Standard section: a) "We, the undersigned, hereby warrant that we are the owner(s) and the only (party/parties) having any interest in the land shown on this plan, and we consent to the subdivision of said land in the manner shown hereon." b) "We hereby grant to the Public and all utility companies all easements as shown hereon for the purposes of access for installation and maintenance of public sewers and utilities and other uses as designated by this plan." c) "(I/We), the undersigned, do hereby hold harmless the City of Tucson, its successors and assigns, their employees, officers, and agents from any and all claims for damages related to the use of the property depicted on this plan now and in the future by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall." d) Add the signature lines for the property owners. 15) DS Sec.2-03.11.9.C: Provide a 5"x5" box for the County Recorder stamp. The title over the box must read, "RECORDING DATA". 16) DS Sec.2-03.11.10.B: Revise the Record of Survey to indicate all existing easements with recordation information on the subject property, specifically the "Enjoyment" easement and the ingress-egress and utility easements that are shown on the proposed Condominium Conversion Final Plat. 17) DS Sec.2-03.11.10.C.1: Provide the description for the 2 found physically monumented points for the Basis of Bearing shown on the plan. If the monuments at each end of the reference line are fully described on the plan, they need not be described in the Basis of Bearing statement. If the monuments are not described provide the recordation information for the Basis of Bearing Section. 18) DS Sec.2-03.11.10.C.3: Revise the Record of Survey to show all boundary monumentation labeled as "found" or "set." Provide a ½ inch iron rod tagged by a registered land surveyor for all set property corners and/or fully describe and show all markings on found monuments. 19) DS Sec.2-03.11.11.A: Verify that all easements of record are drawn on the plan, and recordation information, locations, widths and purposes are included. Provide a copy of the latest Title Report that shows all existing or abandoned easements must be current within 90 days. 20) DS Sec.2-03.11.11.B: Revise the Record of Survey to provide all of the following information regarding the existing public right of way for Blacklidge Drive: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts and sidewalks. 21) DS Sec.2-03.11.11.C: Provide the location of any adjacent fire hydrants, storm drains and sanitary sewers, including pipe diameter and the invert and rim elevations of all manholes and clean outs. If water mains and sewers are not located on or adjacent to the property indicate the direction, distance to, and size of those nearest the property. This information should be included on the supplemental sheet only. 22) DS Sec.2-03.11.12.A: Verify on the Record of Survey that all proposed easements (utility, sewer, access, etc.) are dimensioned and labeled as to their purpose and whether they will be public or private. Recordation information must be included on the plan prior to final approval. 23) DS Sec.2-03.11.12.E: Revise the Record of Survey to clearly show all proposed or existing driveway locations. A driveway can only access two units. Accessing 3 or more units off a single access point require the development of a street or a PAAL. The development of a street or a PAAL requires a plat process; clarify the driveway location and the need for a PAAL. GENERAL COMMENTS: Please provide a revised Record of Survey and a current Title Report that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the Record of Survey and additional documentation. For any questions or to schedule a meeting, call me at (520)-837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 04/07/2008 | FRODRIG2 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | To Whom it May Concern: The attached PDF contains the estimated trip generation information for the project S08-033. Summary: CASE: S08-033 COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS. Vehicle Trip Generation: Daily: 19 PM Peak: 2 Please do not hesitate to contact me if you have any questions, Sincerely, Sandy Sandra C. Holland Senior Statistical/ Research Analyst Pima Association of Governments 177 N. Church Ave, Suite 405 Tucson AZ 85701 Tel: 520 792 1093 X462 Fax: 520 620 6981 |
| 04/07/2008 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | A Docket & Page needs to be provided for the Ingress-Egress Easement concerning Parcel A access to Parcel B |
| 04/07/2008 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | A Docket/Page needs to be provided concerning Ingress-Egress Easment for Parcel A access through Parcel B. |
| 04/07/2008 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | A docket/page need to be provided on the Ingress-Egress Easement for Parcel A to have access to Parcel B. |
| 04/07/2008 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | A docket/page need to be provided on the Ingress-Egress Easement for Parcel A to have access to Parcel B. |
| 04/07/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | A Docket & Page needs to be provided for the Ingress-Egress Easement concerning Parcel A access to Parcel B |
| 04/07/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | A Docket/Page needs to be provided concerning Ingress-Egress Easment for Parcel A access through Parcel B. |
| 04/07/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | A docket/page need to be provided on the Ingress-Egress Easement for Parcel A to have access to Parcel B. |
| 04/07/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | PARKS AND RECREATION DEPARTMENT COMMENTS City of Tucson CDRC - Community Design Review Committee CASE NUMBER: S08-033 CASE NAME: 1128 E. Blacklidge: Record of Survey Submittal #: 1 COMMENTS DUE: 4/9/08 COMMENTS SENT: 4/7/08 Items being reviewed: Record of Survey Relevant Information: Cragin-Keeling Area Plan Parks and Recreation Department Staff has reviewed this proposal and offers the following comments: APPROVED - No resubmittal required. No comments. REVIEWED BY: Joanne Hershenhorn DATE: 4/7/08 S:\PARKS_AND_RECREATION_DEPT\REVIEW_COMMENTS\CDRC_Cases\2008_ReviewsS08-033_1128_E_Blacklidge_ROS.doc |
| 04/10/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department, Plans Coordination Office FROM: Heather Thrall, Senior Planner PROJECT: S08-033, 1128 E. Blacklidge Drive, Record of Survey, 1st review TRANSMITTAL DATE: April 10, 2008 DUE DATE: April 9, 2008 COMMENTS: 1. THE PROJECT - AS PROPOSED - CANNOT PROCEED. The lot identified as Parcel C, as represented in the drawing and in an aerial photo, is essentially an un-buildable lot. The city cannot allow a lot to be created that cannot be developed with a primary permitted use (i.e. residentially occupied structure) meeting code standards. This parcel C is an area used for a one way egress route through the site - which is essential for the access of the development on parcel B. It does not appear that a residence could be placed on parcel C, meeting setbacks from the property lines and the PAAL, provide sufficient parking - nor meeting lot coverage maximum requirements. In addition, the development of parcel C will require full code compliance. If the applicant can demonstrate parcel B can function with an alternative access plan that will not require parcel C's heavy involvement, staff can further review the proposal. AS A COURTESY, STAFF DID REVIEW YOUR PROJECT FOR RECORD OF SURVEY NOTATIONS AND OTHER CODE RELATED ITEMS. 2. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a record of survey. If, at the end of that time, the record of survey has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this record of survey is March 12, 2009. 2. This project was reviewed for compliance with the Land Use Code (LUC) and Development Standards (DS). The content of the Record of Survey was reviewed for compliance with DS 2-03.11. 3. Per DS 2-03.11.7.B, please provide a 2 inch margin on left side of the document. 4. Per DS 2-03.11.7.D.3, on location map, please note adjacent section numbers. 5. Per DS 2-03.11.7.E, place words "Book ____" and "Page ____" in both upper and lower right corners outside margin line. 6. Per DS 2-03.11.7.F, please provide a title block in LOWER RIGHT CORNER - with: A) first line must read "Record of Survey" B) provide proposed name of record of survey C) note the number of lots proposed 7. Per DS 2-03.11.8.A.1, please list the names, addresses, phone numbers of site owners. 8. Per DS 2-03.11.8.B.1, place subdivision case number "S08-033" next to title block. 9. Per DS 2-03.11.8.B.2, list as general note "Existing zoning is R-2." 10. Per DS 2-03.11.8.B.3, add the following note "The number of lots is 2." 11. Per DS 2-03.11.8.B.4, add a note listing the gross area of existing parcel (acreage and square feet). 12. Per DS 2-03.11.8.B.5, add the note "There will be no further division of lots without the expressed approval of the City of Tucson." 13. Per DS 2-03.11.8.C.1, add the note "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." 14. Per DS 2-03.11.9.C, add a 5"x5" box for the County Recorders stamp. The title over the box must read "Recording Data." 15. Per DS 2-03.11.11.A - regarding easements: A) provide an access easement to Parcel C over both Parcels A & B B) provide recordation notation "docket ____ & page _____" next to all easements C) provide copies of recorded easements and recordation receipts D) please ensure that all easements are on the drawings 16. Please note, LUC 2.3.5, and LUC 3.2.5.1.A mandates that a detached accessory structure cannot be on a lot by itself - a principal permitted land use - i.e. residence - must be on the site for the laundry room to remain. It must be removed. 17. Dimension the width of the parcel C and provide the building setbacks between parcel B and C. 18. Please note, further review comments may be forthcoming, depending upon the responses provided. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951. C:\planning\cdrc\developmentplan\S08-033 1128 e blacklidge rs.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised record of survey and additional documents. |
| 04/14/2008 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | April 9, 2008 To: Peter Solanga, PE Oracle Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________ From: Felipe Ip, Sr. Civil Eng. Assistant Development Review Division Pima County Development Services Department Subject: Record of Survey and Site Plan Lot 12 in Catalina Poultry, 1st submittal S08-033 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Please add ‘SITE PLAN’ to the title block for the Reference Only sheet. Please add ‘RECORD OF SURVEY’ to the title block for the sheet with all the surveying information of this proposed minor land division. Add the words “Book____Page____” in both the upper and lower right corners outside the margin line. Add the project number, S08-033, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers (e.g. re-zonings, etc). Please provide evidence of a joint sewer use and maintenance agreement due to lot split in 2007. No connection permit is found for the duplexes. Please contact Ms. Ilene Deckard of the Pima County Wastewater Management Department (740-6544) to create a JOINT SEWER USE AND MAINTENANCE AGREEMENT for the portions of the private sewers that are shared. The agreement will need to be reviewed and approved by the Pima County Wastewater Management Department. Site Plan and Record of Survey: If private sewers exist within the ingress-egress and utility easements shown on the site plan and on the Record of Survey, please change the easement labels to “INGRESS-EGRESS/UTILITY EASEMENT/PRIVATE SEWER EASEMENT by DKG____ and PG ____”. The easements must also be “private sewer easements for the benefit of adjacent parcels”, and be labeled accordingly on the Results of Survey. Record the easements and fill in the recording information, prior to approval and recordation of the Record of Survey. Record of survey: Please add Ownership, Zoning and Land Use notes. Add Dedication. Record of Survey: Please add a Permitting note that states: PRIOR TO SALE OF PARCEL A, PARCEL B OR PARCEL C OR ANY LOT THAT IS SHARING PRIVATE SEWERS, A JOINT USE AND MAINTENANCE AGREEMENT MUST BE RECORDED FOR THE SHARED PRIVATE SEWER. THIS AGREEMENT MUST BE REVIEWED AND APPROVED BY THE PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT PRIOR TO RECORDATION. Record of survey: Add a General Note so it states: ANY RELOCATION OR MODIFICATION OF EXISTING UTILITIES AND/OR PUBLIC IMPROVEMENTS NECESSITATED BY THE PROPOSED DEVELOPMENT WILL BE AT NO EXPENSE TO THE PUBLIC. Site Plan: Add a General Note so it states: MAINTENANCE AND OPERATION OF THE PRIVATE SANITARY SEWERS (HCS) TO ITS POINT OF CONNECTION TO THE PUBLIC SEWER IS THE RESPONSIBILITY OF THE PROPERTY OWNER(S). Site Plan: Show the public and private sewer lines using different line-types, so that they can readily be distinguished from each other. Revise the Legend block accordingly. Site Plan: Please provide additional information indicating existing on-site private sewers and their points of connection to the public sewer. Show how the buildings in the three proposed parcels are being sewered? Show and label all the HCS connections to the public sewer main for all the buildings shown on the proposed Parcels A, B and C.. Site Plan: Revise the plan to show and label all public sewer elements that are located within 100’ or shown on this project. Label existing sewer lines with their Pima County construction plan numbers, pipe sizes, pipe materials, and flow arrows. Label all public manholes that are downstream from any existing and proposed House Connection Sewer (HCS) for this project with their IMS numbers, and rim and invert elevations. For example, show and label the existing public sewer main north of the proposed project as EXIST. 8” VCP I-651 and the existing public manholes as EXIST MH 9236-10 and EXIST MH 9236-11. Existing public sewer information may be found on the PCRWRD Maps and Records (5th floor) or on the PCRWRD and PCDOT MapGuide internet websites. This office will require a revised set of plans, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If you have any questions regarding the above mentioned comments, please do not hesitate to contact me at 520-740-6706. CC: Project file |
| 04/16/2008 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. No provisions shown or mentioned for refuse and recycle collection services. Must comply with DS 6-01.0. Clarify Please provide clarification to above comment on resubmittal. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 04/17/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES April 17, 2008 Peter Salonga Oracle Engineering Group 199 East fort Lowell Tucson, Arizona 85705 Subject: S08-033 Blacklidge Record of Survey Dear Pete: Your submittal of March 13, 2008, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 9 Copies Revised Record of Survey (Fire, Landscape, Addressing, Real Estate, Engineering, Zoning, Wastewater, ESD, DSD), 2 Copies Title Report (Engineering, DSD) Should you have any questions, please call me at 879-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 292-6144 |
| 04/17/2008 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review | |
| 04/17/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | February 22, 2010 Peter Salonga Oracle Engineering Group 199 East Fort Lowell Road Tucson, Arizona 85705 SUBJECT: CLOSURE OF CDRC FILES Record of Survey Per Section 4.1.7.3, Maximum Review Period The subdivider has one (1) year from the date of Record of Survey submittal to obtain approval of the plans. Failure to obtain approval means the review period has expired Case # Case Name DSD Transmittal Date S08-033 Blacklidge Record of Survey March 12, 2008 Please note that this case has been closed and that, in order to continue review of the project, new development plan/tentative plat applications are required which comply with regulations in effect at the time of the new submittals. Thank you for your assistance. Sincerely, Patricia Y. Gehlen CDRC Manager xc: CDRC file S08-033 |