Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S08-022
Parcel: Unknown

Review Status: Completed

Review Details: ASSURANCES

Plan Number - S08-022
Review Name: ASSURANCES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2008 FERNE RODRIGUEZ START ASSURANCES RECEIVED Completed
03/28/2008 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: March 28, 2008
CDRC/Zoning Manager FROM: Paul Machado
Engineering Division
SUBJECT: Columbus Village505 S. Columbus Blvd. FP
Final Plat S08-022 (First Review)
T14S, R14E, Section 15

RESUBMITTAL REQUIRED: Final Plat.

The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies of the FP.
2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used:
" Title Report
" Special Warranty Deed
" Trust Agreement
" Amendment to Trust
" Agreement to Construct
Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review.
3. The title block of the plat must match the Subdivision Assurances verbatim.
4. A title block with the following information……………………..per D.S. 2-03.2.1.G.
5. Add applicable zoning, land use and Drainage notes…………….per D.S. 2-03.2.2., D and G. On note 3 of the general notes, list the length of new public street as "0" instead of N/A. Is this an easement or a street?
6. Show all existing conditions………………………………………per D.S. 2-03.2.3.A, B, C, D, E, F, G, H, I and J.
7. Show sight visibility triangles per D.S. 2-02.2.1.10. Future an existing.
8. Complete the case no. S08-022.
9. Add the following notes to the FP per D.S. 2-03.2.4, A, B, I, J.
10. Show a 1' no access esmt. along the west property line of lot 1and in the easement between lots 4 and 5 per D.S. 2-03.6.4.G
11. At least one corner shall be tied by course and distance to the subdivision… per D.S. 2-03.6.5.A.
12. Show all distances as calc'ed or measured… per D.S. 2-03.6.5.C.5.
13. The esmt. shall include pedestrian dedication also. Where will the water meters be placed in the esmt.?
14. Please submit a copy of the subdivision boundary closure calculations.

Drainage Report:
1. The DR has been accepted by engineering.
2. This review was performed for FP purposes only.



If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/505 S. Columbus Blvd. FP