Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S08-002
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/16/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: July 16, 2008 SUBJECT: 3225 E Kleindale: Minor Subdivision - Engineering Review (4th Review) PROJECT ADDRESS: 3225 E Kleindale, T13S R14E Sec 28, Ward 3 ACTIVITY NUMBER: Minor Subdivision Review - D08-002 PROJECT REVIEWER: Bianca Ramirez, CFM SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed Minor Subdivision Review Site Plan (1st Review) for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed: 1. Complied 2. Complied 3. Complied 4. DS Sec. 2-03.6.1.B: Verify that a minimum two (2) inch margin is provided on the left side of both sheets. 5. Complied 6. Complied 7. Complied 8. Complied 9. Complied 10. Complied 11. Complied 12. Verify that all dedication wording matches the wording that is outlines in the development standard. 13. Complied 14. Complied 15. Complied 16. Complied 17. Complied 18. From benchmark along Kleindale Rd 1058.96' BM should be revised to be BOB (Basis of Bearing). Indicate if (R) and/or (M). Provide bearing. 19. Complied 20. Additional Comments may be forthcoming. If you have any question please feel free to e-mail me at bianca.ramirez@tucsonaz.gov or call me at 837-4928. Bianca C. Ramirez, CFM Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 07/18/2008 | TERRY STEVENS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S08-002 3225 E. Kleindale Minor Subdivision TRANSMITTAL: 07/18/2008 DUE DATE: 08/05/08 COMMENTS: 1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 2. The City Clerk is no longer Kathleen S. Detrick. In the Approval section on the final plat change the name to Roger W. Randolph. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\finalplat\S08-002fpca-2.doc |
| 07/23/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 08/12/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S08-002 3225 E KLEINDALE/MINOR SUB REVIEW DATE: 7/25/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 08/16/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 16, 2008 Rose Duarte-Pina E.S.P. LLC 2030 East Broadway Blvd., Suite 3 Tucson, Arizona 85719 Subject: S08-002 3225 East Kleindale Final Plat Dear Rose: Your submittal of July 8, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Final Plat (Engineering, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 647-2788 Tp-resubmittal |
| 08/16/2008 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review |