Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S08-001
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S08-001
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/22/2008 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S08-001 LOWES HOME IMPROVEMENT CENTER/FINAL PLAT
DATE: January 17, 2008



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Revise Title Block to read “A resubdivision of Lots 1-6 of Sunrise Place, Bk 31, Pg 81.


jg
01/28/2008 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: LOWES HOME IMPROVEMENT CENTER

S08-001



Tucson Electric Power Co. (TEP) approves the final plat submitted for
review January 7, 2008.

Please forward any resubmittals of the final plat to this office.



Please contact me at (520) 917-8745 if you have any questions.




Liza Castillo, Right of Way Agent
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
02/05/2008 FRODRIG2 COT NON-DSD REAL ESTATE Denied S08-001 Lowes Home Improvement Center: Final Plat Review
-On Sht. 1, request "Sppedway Blvd." annotation be moved w/in the R/W corridor.
-"Beneficiary" block needs to show the beneficiaries of Sunrise LG, L.L.C.
-Request "Dedication" block contain language to convey 24,481 sq. ft. along Pantano Wash to Pima Co., as shown on Sht. 3 & 4.

Andy
(520) 837-6715
Real Estate Division

fax 791-5641
02/05/2008 FRODRIG2 PIMA COUNTY WASTEWATER Denied Jan 30, 2008

To: Thomas Sayler-Brown, Registered Architect
SBBL Architecture & Planning

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Felipe Ip, Sr. Civil Eng. Assistant (520-740-6706), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Lowes Home Improvement Warehouse
Subdivision Plat/Tentative Plat - 1st Submittal
S08-001

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


All Sheets: Update the assigned development plan case number, S08-001, to the title block. This number should be shown larger or bolder than any cross reference numbers.

Sheet PL1: On the second paragraph of the Dedication Block, please remove the wording ‘PIMA COUNTY’ and ‘PUBLIC SEWERS AND’ so that it states

WE HEREBY GRANT TO THE CITY OF TUCSON AND ALL UTILITY COMPANIES AS SHOWN HEREON FOR THE PURPOSES OF ACCESS FOR INSTALLATION AND MAINTENANCE OF UTILITIES AND OTHER USES AS DESIGNATED BY THIS PLAT.

Sheet PL1: Add a GENERAL NOTE so it states:

THE ON-SITE SANITARY SEWERS, EXCEPT PUBLIC SEWERS WITHIN PUBLIC SEWER EASEMENTS OR RIGHTS-OF-WAY, WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT.



Sheet PL1: Add a GENERAL NOTE so it states:

MAINTENANCE AND OPERATION OF THE PRIVATE SANITARY SEWERS TO ITS POINT OF CONNECTION TO THE PUBIC SEWER IS THE RESPONSIBILITY OF THE PROPERTY OWNER.

Sheet PL1: Add a GENERAL NOTE that states:

THE ON-SITE SEWERS ARE EXISTING AND PRIVATE. NO NEW SEWERS ARE PROPOSED.

Sheet PL3: Please verify the 25’ sewer easement recording information. On the development plan D04-003, the Docket and Page information is different from the ones given on this plan.

Is there an existing approved operation and maintenance plan for the on-site private sewers? If yes, please provide documentation such as recorded Covenants, Conditions and Restrictions (CC&R) or a recorded Joint Sewer Use and Maintenance Agreement with the recording information (Docket and Page numbers). If no, who is responsible for maintaining the private sewers (i.e., Lot Owners Assoc.)?

If a JOINT SEWER USE AND MAINTENANCE AGREEMENT for the portion of the on-site private sewers that are shared by proposed lots is required, such agreement will need to be reviewed and approved by Ms. Ilene Deckard of the Pima County Regional Wastewater Reclamation Department (740-6544). Before this office will be able to approve this lot split (or Record of Survey), the new Joint Use and Maintenance Agreement will also need to be recorded.

Provide a site plan that shows all the existing sewers and utilities to accompany the next submittal. The plan needs to show and label all public sewer elements that are located within 100’ or shown on this project.
Label existing sewer lines with their Pima County construction plan numbers, pipe sizes, pipe materials, and flow arrows.
Label all public manholes that are downstream from existing Building Connection Sewer (BCS) for this project with their IMS numbers and invert elevations.
Existing public sewer information may be found on the PCRWRD Maps and Records (5th floor) or on the PCRWRD and PCDOT MapGuide internet websites.

It is recommended that you attend a Subdivision Design Review Committee (SDRC) meeting to discuss about this lot-split proposal.

This office will require a revised set of plans, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of plans and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter.

CC: Project File
02/07/2008 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 02/07/2008,


TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Lowe's Home Improvement Center
S08-001, T14S, R15E, SECTION 05
Formerly S05-184

RECEIVED: Final Plat on January 07, 2008

The subject project has been reviewed. Provide the following information on the Final Plat:

1. D.S. 2-03.6.6.1.G. Place the words "Book ____ Page ____" are missing in the upper right corner of Sheet 1 of 4.
2. D.S. 2-03.6.6.3.C. The Trust number shall be provided in the Beneficiary Block. Please clarify if a Trust number is needed for this project.
3. D.S. 2-03.6.5.C.5. Indicate whether the distance and bearing between all monuments used measured or calculated. The response says that all distances and bearings are measured but it does not appear that this is clearly shown on the plat.
4. D.S. 2-03.7.1.G. Provide a copy of the assurances documents for review. Clarify if assurances are needed for this project. It appears that the project is already built out and assurances may not be required.

Prepare a detailed response that explains the revisions that were made and references the exact location on the Final Plat where the revisions were made.


RESUBMITTAL REQUIRED: Revised Final, and Assurances
02/12/2008 PETER MCLAUGHLIN ZONING REVIEW Denied 1. Add the CDRC subdivision case number (S08-001) to all sheets of the final plat. DS 2-03.6.1.K

2. Revise the dates in the Approval and Recording Data Blocks to read "2008".

3. Add the words "Book" and "Page to the upper right hand corner of sheet 1. In order to do so it will be necessary to shift the location map to the left to allow room.

4. Add the trust number to the beneficiary block.
02/12/2008 GLENN HICKS COT NON-DSD PARKS & RECREATION Denied PARKS AND RECREATION DEPARTMENT COMMENTS

City of Tucson CDRC - Community Design Review Committee


CASE NUMBER: S08-001
CASE NAME: Lowe's Home Improvement Center: Final Plat
Submittal #: S08-001

COMMENTS DUE: 2/5/08 COMMENTS SENT: 2/11/08


Items being reviewed: (ü) Tentative or Final Plat
( ) Development Plan
( ) Landscape Plan
( ) Other -

Related Cases: annexation - N/A
rezoning - C9-03-23
CDRC - D04-003, S05-184

Parks and Recreation Department Staff has reviewed this proposal and offers the following comments:


( ) APPROVED - No Resubmittal Required.

( ) No comment
( ) Proposal complies with annexation or rezoning conditions
( ) Proposal satisfies trails, recreational amenities, and/or parks and open space requirements
( ) No additional comments - complies with comments submitted on:


(ü) NOT APPROVED - Resubmit the following. See attached comments.

(ü) Tentative Final Plat
( ) Development Plan
( ) Landscape Plan
( ) Other -


REVIEWER: Joanne Hershenhorn DATE: 2/11/08


S:\PARKS_AND_RECREATION_DEPT\REVIEW_COMMENTS\CDRC_Cases\2008_ReviewsS08-001_Lowes_Spdwy_Kolb.doc
PARKS AND RECREATION DEPT. COMMENTS
S08-0001


1) The 45-foot wide Pantano Wash linear park needs to be dedicated to the City of Tucson (please include the specific wording "dedicated to the City of Tucson"). Based on a review of previous documents, including D04-003 and D2005-007, and using the Lowe's eastern property line as a reference, those areas extending 32 feet west of and 13 feet east of that property line are to be dedicated to the City of Tucson. The 13-foot eastern-most section is that area of the river park that is cantilevered out over the bank protection. The 32-foot-wide section is that portion of the river park west of the cantilevered section on the Lowe's property.

Please indicate that the Pantano Wash and the bank protection are dedicated to Pima County or the Pima County (Regional) Flood Control District, as appropriate.

2) To facilitate access to the river park for maintenance purposes, the City will need an access easement along the northern boundaries of Lots 1 and 2, and curving around lot 2 to the southeast, connecting to the northern terminus of the river park. There are existing parking area access lanes (PAALs) in this area. Please show the access easement, dedicated to the City of Tucson by plat.

If you have any questions or would like to discuss the above comments, please call Joanne Hershenhorn at 791-4505. Thanks.
02/22/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 22, 2008

Thomas Sayler-Brown/Carolyn Lemmon
SBBL Architecture and Planning
1001 North Alvernon Way #105
Tucson, Arizona 85711

Subject: S08-001 Lowes Home Improvement Final Plat

Dear Thomas/Carolyn:

Your submittal of January 7, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

7 Copies Revised Final Plat (Addressing, Wastewater, Real Estate, Engineering, Parks and Recreation, Zoning, DSD)







Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 620-0535
fpresubmittal