Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S07-204
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S07-204
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/18/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/22/2008 JIM EGAN COT NON-DSD FIRE Approved
04/24/2008 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond April 23, 2008

To: HANK HULBERT
LEADS & CEI ENGINEERING ASSOCIATES, INC.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: CIRCLE K SWC VALENCIA ROAD & NOGALES HIGHWAY
Tent. Plat – 2nd Submittal
S07-204


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Sheet 3: Show the public sewer continuing north from Manhole #8936-23XP and connecting to the line drawn for public sewer #G-107 at the intersection of Valencia and Nogales Hwy. Also show the symbol for existing public manhole #8936-23XP with the stubout going east of this manhole in Valencia Rd.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative or preliminary plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.
If you have any questions regarding the above-mentioned comments, please contact me.
04/30/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied All lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size. Much of the text within the drawing on sheet L-1 does not meet this mimum requirement. Revise where necessary. DS 2-05.2.1.A
04/30/2008 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S07-204 CIRCLE K STORE/REVISED TENTATIVE PLAT
DATE: 4/29/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.





***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***

ES
05/13/2008 ANDY STEUART COT NON-DSD REAL ESTATE Approv-Cond -Request Dkt. 9121 Page. 721, Recorded 9/11/91, be annotated to show the dedication of the N. 15' of Subject Property for R/W purposes.
-Per 5/13/08 conversations w/ Jose Ortiz, COT/Eng. & Jim Stoynoff, COT/R.E. (RES 2008-053), request proposed dedication of R/W along Nogales Hwy be conveyed by Final Plat and not by separate instrument.
05/14/2008 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Circle K Store - Southwest Corner of Valencia & Nogales Highway
Tentative Plat/Development Plan
S07-204 (2nd Review)

TRANSMITTAL DATE: May 14, 2008

DUE DATE: May 16, 2009

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat/development plan. If, at the end of that time, the tentative plat/development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is January 03, 3009.

2. Zoning acknowledges that the zoning has been changed on sheet C-2. Revise PERMITTING NOTE 1 to reflect the correct proposed zoning. It appears that the proposed zoning for this project has changed. Per re-zoning case # C9-06-10 and PDP-1, revised 06/23/06, the proposed zoning was C-1 & C-2. Per the submitted tentative plat the proposed zoning is all C-2. This change will require a new re-zoning, contact, Michael Wynekin @837-4955.

The following comments are based on the requirements of D.S 2-05 - Development Plan Standards.

1. D.S. 2-05.2.4.C As this project is to be phased, provide calculations (site area, floor area ratio, building height), setbacks, etc., to indicate that each phase complies with all requirements as a separate entity. Show and label any temporary improvements that may be needed to make the site function for each phase as one entity. If such temporary improvements are off the site of the phase under consideration, a temporary easement or other legal documentation to assure legal use of the property is required. Note recording information. It appears that some type of access agreement will be necessary for the proposed 24' parking area access lane (PAAL) located south of the Phase 1 building. Also per D.S. 3-05.2.3.C.1 some type of barrier will be required to prevent vehicle access to the Phase II area, show this on the plan.

After discussions with Ron Brown, Structural Review, City of Tucson, Development Services Department in regards to the ICC/ANSI A117.1-2003 and the requirements for detectable warnings (truncated domes), it has been determined that some locations previously requiring truncated domes may no longer require them. The following comments are a direct result of these discussions. If you have any questions in regards to the requirements for truncated domes contact Ron Brown @837-4908:

2. D.S. 2-05.2.4.K Truncated domes are not required at the proposed accessible vehicle parking space access aisle ramps. Truncated domes are required at all other ramps shown on the plan.

3. D.S. 2-05.2.4.M Provide, as a note, the square footage of each commercial, industrial, or business structure and the specific use proposed.

4. D.S. 2-05.2.4.Q On the provided bicycle parking detail indicate the materials for lighting. Also per D.S. 2-09.5.1.B show the required 36" to a perpendicular wall. For your information a single inverted "U" bicycle rack supports two (2) bicycles.

5. D.S. 2-05.2.4.R It appears that the sight visibility triangles (SVT's), future and existing, shown for the entrance off of Nogales Highway are not shown correctly. See Engineering comments.

6. D.S. 2-05.2.4.U Provide a separate letter stating how each re-zoning condition has been complied with.

7. D.S. 2-05.2.4.V Indicate the location and type of postal service proposed for this site.

8. D.S. 2-05.2.4.W Zoning acknowledges the proposed monument signs shown are under separate permit. If the future SVT's remain as shown, see comment 5, a Development Standard Modification Request (DSMR) will be required at the time of permitting. Provide a note on the plan stating this.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\tentativeplat\S07-204tp-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat/development plan, site plan and additional requested documents.
05/19/2008 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S07-204 Circle K Store

(XXXX) Tentative Plat
() Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-06-10

NEIGHBORHOOD PLAN: 12th Avenue/Valencia Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 05/16/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 2/4/08
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other – Elevations

REVIEWER: drcorral 791-4505 DATE: 05/09/08
05/19/2008 ANDY VERA ENV SVCS REVIEW Approved
06/13/2008 JASON GREEN ENGINEERING REVIEW Denied DATE: August 12, 2008
SUBJECT: Circle K Tentative Plat/Development Plan- 3rd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: Parcel ID 138-16-001F, T15S R13E Sec13 Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: S07-204


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Tentative Plat/Development Plan, Drainage Statement (L.E.A.D.S., Inc., 28JUN07, revised 17APR08) and Geotechnical Investigation Report (Foree&Vann, Inc., 14SEP07 with addendum 19FEB08). Engineering Division does not recommend approval of the Tentative Plat/Development Plan at this time. The Drainage Statement was reviewed for Tentative Plat/Development Plan purposes only. The following items need to be addressed:


DEVELOPMENT PLAN:

1) DS Sec.2-05.2.4.C: Revise the Tentative Plat and the proposed phase lines to show that all right-of-way improvements are to be constructed under Phase I. The curb returns, vertical curbing, handicap access ramps and sidewalk must be constructed under the Phase I improvements.

2) DS Sec.2-05.2.4.C: Clarify on the Tentative Plat exactly how the water from the south side of Building 1 and from the proposed drive drains. Per the comment letter it states "The water from the drive has been designed to flow into the catch basin located east of the Circle K building until the additional inlets and piping are provided in Phase II of this project", where does the water go once it reaches the catch basin? Provide a revised Drainage Report or addendum that provides the proposed drainage solution for Phase I drainage. If the idea is to drain the water into the catch basin and then into the proposed water harvesting area, specifically label and show the drainage improvements required. If the water harvesting area at that point is being used as a retention basin then clarify the required drain down time to insure that water is disposed of within the required 12 hour limit.

3) DS Sec.2-05.2.4.C: Provide the recordation information on the Tentative Plat/Development Plan for the required access agreement that was provided at this submittal for the Phased development.

4) DS Sec.2-05.2.4.W: Revise the Tentative Plat/Development Plan to provide the monument sign note shown on Sheet C-2 under either the General Note section or the Permitting Note section on Sheet C-1. A Development Standard Modification Request (DSMR) will be required at the time of permitting if the monument sign is proposed within the future SVT.

5) DS Sec.2-05.2.4.U: Indicate graphically, where possible, and by notes, in all other instances, compliance with conditions of rezoning, specifically for engineering:

a) Rezoning Condition # 10- The owner/developer shall construct a bus pull-out/pull-through and a bus shelter on the Old Tucson-Nogales Hwy (US 89) as determined by the Department of Transportation. Provide approval for the proposed bus shelter shown on the Development Plan. No email was attached with the submittal from Tom Fisher as stated in the comment letter.
b) Rezoning Condition # 16- The owner/developer shall provide for signal improvements at the intersection of Valencia Road and Nogales Hwy not to exceed $25,000. It is acknowledge that TDOT is in discussion on this, provide email correspondence from TDOT to verify that this rezoning comment has been addressed.
c) Rezoning Condition # 21- An archaeological assessment and survey shall be performed by a qualified archaeologist before any grading or other ground modification takes place. Acknowledged, this will be required at grading plan approval.

6) A private improvement agreement (PIA) is required for the proposed work within the public right-of-way. An approved site plan is required prior to applying for a PIA. Contact the PIA Coordinator for additional PIA information at 791-5550 ext. 1107.

7) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications:

a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html /

b) http://www.dot.ci.tucson.az.us/engineering/pia.php

c) Or contact Thad Harvison at 837-6592 for all additional questions regarding r-o-w.


GRADING PLAN:

8) DS Sec.11-01.2.1: A grading permit will be required for this. A grading plan and a grading permit application will be required after Tentative Plat/Development Plan approval and prior to any construction activity. A grading permit may not be issued prior to Tentative Plat/Development Plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the Tentative Plat/Development Plan.

9) Please ensure that any future grading plan will be consistent with the Tentative Plat/Development Plan, Drainage Statement, and geotechnical report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf .

10) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with a grading plan submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html.

11) Provide a general note on the grading plan that references the City of Tucson Development Standard 11-01.0 (excavation and grading requirements).


GENERAL COMMENTS:

Please provide a revised Tentative Plat/Development Plan, Drainage Statement and TDOT approval for the above comments that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Tentative Plat/Development Plan, Drainage Statement, and geotechnical report reviews.

For any questions or to schedule a meeting call me at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
06/18/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 18, 2008

Hank Hulbert
LEADS, Inc.
2400 North Central Avenue, #203
Phoenix, Arizona 85004

Subject: S07-204 Circle K Store Tentative Plat

Dear Hank:

Your submittal of April 21, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Tentative Plat (Wastewater, Landscape, Real Estate, Engineering, Zoning, DSD)

5 Copies Revised Landscape Plan (Landscape, DUPD, Engineering, Zoning, DSD)

2 Copies Color Elevations (DUPD, DSD)

2 Copies Drainage Statement (Engineering, DSD)

2 Copies Geotechnical Report (Engineering, DSD)


Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (602) 254-1700