Plan Number: S07-182
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL-FINAL PLAT - CONDO CONVERSION

Plan Number - S07-182
Review Name: RESUBMITTAL-FINAL PLAT - CONDO CONVERSION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/21/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/10/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: June 10, 2008
SUBJECT: Lot 176 Valencia Road Condominium Conversion Final Plat Submittal- 2nd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 2111 E Valencia Road, T15S R14E Sec 08 Ward 5
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: S07-182


SUMMARY: Engineering Division of Development Services Department has received, Sheet 1 and 2 of the proposed revised final Plat, and copy of the CC&Rs. Engineering Division has reviewed the submitted Final Plat and CC&Rs and does not recommend approval of the Final Plat or CC&Rs at this time. The following items need to be addressed:


FINAL PLAT COMMENTS:

1) Complied

2) DS Sec.2-03.6.3.A: For Final Plat approval the Certificate of Survey section must be sealed and signed by the Surveyor and Engineer of Record prior to Mylar submittal. The word "Preliminary" works for initial review (must be included on both stamps), however final Mylar approval will not be given until the Final Plat is sealed and signed. Note: It appears that the preliminary block is not snapped over the digitized stamp. May want to have drafter fix and save so that it is not an issue of future projects. Engineering digitized stamp along with preliminary note appears to be correct. It is acknowledges that mylar will be signed. But, all stamps must either signed and dated or marked as preliminary.


Covenants, Conditions, and Restrictions (CC&Rs):

3) Complied

4) Complied

a) Complied

b) Complied

c) Complied

5) DS Sec.2-03.7.1.F: Since the development is a conversion to a COMMERCIAL condominium development, the affidavits and information, as indicated in the LUC, Section 4.1.9.2 needs to be submitted with the resubmittal of the final plat. Please provide all documentation required the Final Plat can not be approved prior to Zoning review of the above applicable items. - See Zoning Comments.

6) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until one of the following has been provided:

a) If there is any remaining construction, the financial assurances shall be submitted and approvable; or,

b) Provide a copy of Certificate of Occupancy (CofO) paperwork accepted by the City of Tucson for the final construction. Per Matt Flick, PE and David Rivera, Zoning Supervisor a Letter of Completion will not work to satisfy this requirement. A CofO or Assurances must be submitted for review. For further clarity please contact Matt Flick at 837-4931 or David Rivera at 837-4957. - Acknowledge response in comment letter, provide email that states that a Letter of Completion is the equivalent to a Certificate of Occupancy.

7) Please concider providing a table of contents so that it is easier to find the sections provided.

8) Please number each sheet of the pages submitted in the CC&R(s) and provide copy of original signed revised copies.


GENERAL COMMENTS:

Provide a revised Final Plat at resubmittal

The revised Final Plat must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Final Plat.

If you have any questions or to schedule a meeting I can be reached at 837-4929.



Bianca Ramirez, CFM
Engineering Associate
Engineering Division
COT Development Services
06/11/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 11, 2008

Louis Catallini, P.E.
Baker & Associates Engineering, Inc.
3561 East Sunrise Drive, Suite 225
Tucson, Arizona 85718

Subject: S07-182 Lot 176 Valencia Road Condos Final Plat

Dear Lou:

Your submittal of May 21, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Final Plat (Engineering, DSD)

2 Copies CC&R's (Engineering, DSD)






Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 318-1930
fpresubmittal