Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S07-158
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2009 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 04/30/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S07-158 WAL-MART STORE#4684-00/FINAL PLAT DATE: 4/29/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 05/01/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/01/2009 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approv-Cond | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Joyce Hays, Section Supervisor Pima County Assessor’s Office Mapping Department DATE: 04/24/09 RE: Assessor’s Review and Comments Regarding Final Plat Wal-Mart Store #4684, S07-158, Sec 16, T15S, R14E. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * x Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Please include the name, map and plat of any adjacent subdivisions before recording the final plat. Thanks, Brian Sloan Pima County Assessor’s Office 740-4395 NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 05/01/2009 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approv-Cond | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Joyce Hays, Section Supervisor Pima County Assessor’s Office Mapping Department DATE: 04/24/09 RE: Assessor’s Review and Comments Regarding Final Plat Wal-Mart Store #4684, S07-158, Sec 16, T15S, R14E. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * x Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 05/13/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Walmart #4684 - Final Plat S07-158 Final Plat TRANSMITTAL DATE: May 13, 2009 DUE DATE: May 19, 2009 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a plat. If, at the end of that time, the plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is April 20, 2010. 2. D.S. 2-03.6.1.D.2 Identify all subdivisions on the location map, reference recorded subdivision plats by book and page numbers. 3. D.S. 2-03.6.1.D.3 The lower right section reference "21" on the location map is not correct this should be "22". 4. D.S. 2-03.6.1.D.4 As the southern end of section 16 and all of section 15 are not within the City jurisdiction show the City jurisdictional limits on the location map. 5. D.S. 2-03.6.2.D Remove General Note 5 from the plat as there is no rezoning for this project. Case No. C15-88-01 is an Annexation Number. 6. D.S. 2-03.6.2.J Add the following note: "This subdivision is subject to Ordinance No. 7090 which established zoning in the Country Club/Valencia Annexation Area." 7. D.S. 2-03.6.3.D Under the Recording block move "F. ANN RODRIGUEZ" above the line. 8. D.S. 2-03.6.6 Easements with Covenants and Restrictions Affecting Land (ECR), Exhibit A-2 shows a "OUTDOOR SALES AREA" and a "FUTURE EXPANSION" these areas are not shown on the approved tentative/development plan. Either one of these, or a combination of both appear to push the total square footage above the 100,000 square foot threshold therefore are required to be process through a Special Exception Land Use. Remove the "OUTDOOR SALES AREA" and a "FUTURE EXPANSION" from this exhibit. 9. D.S. 2-03.6.6 Easements with Covenants and Restrictions Affecting Land (ECR), Exhibit D-1 shows signage that has not been approved at this time. Remove the references to signs from this exhibit. If needed show only the sign easements. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C\planning\cdrc\finaplat\S07-158fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, and additional requested documents. |
| 05/13/2009 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: May 13, 2009 CDRC/Zoning Manager SUBJECT: Wal-Mart, #4684-00, 3786 E. Valencia Rd. Final Plat S07-158 (First Review) T15S, R14E, Section 16 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used: " Title Report " Special Warranty Deed " Trust Agreement " Amendment to Trust " Agreement to Construct 3. Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review. 4. Label Palo Verde Road on sheet 1. 5. A small, project-location map will be drawn in the upper right corner of the first sheet of the plat at a scale of 3" = 1 mile. The location map shall provide the following information: " The City's jurisdictional limits will be shown, if within the mapped area. 3. Line weights will reflect the nature of the line, e.g., right-of-way lines will be more prominent than lot lines or easements, and drainageways will be in heavy solid lines except at street crossings. 4. A legend which shows and describes all symbols used on the drawing will be placed on either the first sheet of the plat or the first sheet which contains all or part of the subdivision drawing. 5. Indicate the name and width of each street, alley, easement (type), and drainageway within the subdivision boundary being created by this plat. Label each as public or private, along with the appropriate dedication notation. 6. If the project has common areas, label each common area individually with a separate letter designation. Enclose with a solid line each common area, private street, etc., that will have separate restrictions, a separate homeowners' association, or any common area that is separated by a public right-of-way. 7. Show required setbacks, such as erosion hazard, drainage, etc. 8. Show the 50' W.A.S.H. wash setback line. 9. Per FEMA firm panel 2243K, show the limits of the 100-year flood prone area (Zone A) in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines for all flows of one hundred (100) cfs or more. 10. Show detention/retention areas in a surveyable and readily retraceable manner. A common area designation may be used for the ret/det area. This would also create an avenue in which to hold all lots responsible for basin maintenance and can be assured by the CCR's. 11. Additional details to be shown are as follows. " Basis of bearings - The purpose of the basis of bearings on a survey is to enable another surveyor to retrace the original survey. As such, the statement must be referenced to found, readily locatable monuments. " The basis of bearings should be established from two (2) found, physically monumented points described and shown on the final plat. 12. All boundary monumentation must be labeled as "found" or "set." i. Fully describe and show all markings on found monuments. Indicate/call-out if a found monument has no survey information. 13. Please submit a copy of the subdivision boundary closure calculations. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/3786 E. Valencia Rd. FP |
| 05/18/2009 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: WAL-MART STORE #4684-00 S07-158 Tucson Electric Power Co. (TEP) approves the final plat submitted April 21, 2009. Should easements be required to service this development, those easements will be secured by separate instrument. Please forward any resubmittals of the final plat to this office. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent II Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
| 05/20/2009 | FERNE RODRIGUEZ | COT NON-DSD | TUCSON AIRPORT AUTHORITY | Approved | To Whom It May Concern: Thank you for the opportunity to comment on S07-158 Wal-Mart Store #4684, a final plat review application for approximately 15 acres located west of the southwest corner of Valencia and Alvernon. This site is not within the Tucson International Airport or Ryan Airfield public disclosure areas or traffic pattern airspace. The Tucson Airport Authority does not oppose this application. Please contact me if you have any questions or concerns. Respectfully, Jordan D. Feld, AICP Director of Planning Tucson Airport Authority 7005 S. Plumer Ave. Tucson, AZ 85756 jfeld@tucsonairport.org www.tucsonairport.org (520) 573-5115 office (520) 573-8006 fax |
| 05/20/2009 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | May 18, 2009 To: Maolin Zheng BSW International Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E., Civil Eng. Manager Development Review Division (Wastewater) Subject: Walmart Store #4684-00 Lots 1 Through 4, Final Plat, 1st Submittal S07-158 The drawings of the final plat for this project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (RWRD). The following comments are offered for your use: The PDEQ and the PCRWRD hereby approve the above referenced submittal of the Final Plat as received by us on 4/20/09. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. |
| 05/27/2009 | PGEHLEN1 | CC&R | CC&R's | Approved | see engineering comments. |
| 05/27/2009 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Approv-Cond | From: City Mgr. Office/Real Estate Prog., Andy Steuart, Property Agent, (520) 837-6715 Subject: Final Plat, Wal-Mart #4684, S07-158 On Sht. 1 of 3, request the following: 1. Annotate and identify the City/County boundary line that is adjacent to the E. of the Subject Plat. 2. Under Dedication block, 4th paragraph, change "Interstate Commerce Park" to "Wal-Mart #4684, Lots 1-4." 3. Annotate "Acknowledgement" over Notary block. |
| 06/01/2009 | JWILLIA5 | ZONING-DECISION LETTER | REVIEW | Denied | *** REVISED *** COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 10, 2009 Frank Bangs, Jr. Lewis & Roca LLP 1 South Church Avenue, Suite 700 Tucson, Arizona 85701 Subject: S07-158 Wal-Mart #4684 Final Plat REVISED Dear Frank: Your submittal of April 21, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 4 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Final Plat (Assessor, Engineering, Zoning, DSD) 2 Copies Boundary Closure Calculations (Engineering, DSD) 2 Copies Assurances (Engineering, DSD) Should you have any questions, please call me at 837-4919. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 879-4723 |