Plan Number: S07-155
Parcel: Unknown

Address:
3301 S 6TH AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S07-155
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2008 CDRC1 START PLANS SUBMITTED Completed
01/24/2008 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond January 23, 2008


To: Hank Hulbert
Leads + CEI Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Circle K, 3301 S. 6th Avenue
Tent. Plat – 2nd Submittal
S07-155


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Sheet 2: Call out the public sewer easement for the public sewer on the property and also south of the property.

Sheet 2: Show the public sewer line continuing south of the property. It currently does not match what is shown in the Legend for existing public sewer.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.
If you have any questions regarding the above-mentioned comments, please contact me.
01/29/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. The landscape and irrigation plans are difficult to read due to text overlap in many areas of the plans. Revise to make all lettering and dimensions clearly legible. Further comments may be necessary once the plan is made Iegible.

2. All lettering and dimensions must be a minimum of 12 point (0.12") in size for microfilming purposes. Some of the text on the irrigation plan does not meet this minimum archiving standard. Revise as necessary.
DS2-03.2.1.C

3. On the landscape plan a landscape border is shown to be located within the vehicular use area/parking lot in the vicinity of the building setback line as shown on the development plan. Please clarify. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4. Show and dimension the landscape borders clearly and correctly on the landscape plan.
01/29/2008 JOSE ORTIZ COT NON-DSD TRAFFIC Approv-Cond Call out for 25' radius curb returns along northern driveway.
02/05/2008 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S07-155 CIRCLE K/REVISED TENTATIVE PLAT
DATE: 1/31/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***



ES
02/15/2008 ANDY VERA ENV SVCS REVIEW Denied 1. Two single enclosures or one double wide enclosure will be required for this development as this type of business will generate both refuse and recycle materials for collection and disposal.

2. Current access, maueverability, and approach work as shown. Enclosure detail is good.

Please correct/add, as mentioned, on resubmittal.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
02/20/2008 FRODRIG2 COT NON-DSD REAL ESTATE Denied S07-155 Circle K: Resubmittal - CDRC - Tentative Plat Review
-Request confirmation that Tucson Water has no objection to the proposed abandonment of utility easement, per Dkt./Pg. 3460/299.
-On Final Plat, request dedication language be provided concerning proposed R/W along S. 6th Ave.


Andy
(520) 837-6715
Real Estate Division

fax 791-5641
02/20/2008 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Circle K - 3301 S. 6th Ave.
Tentative Plat
S07-155 (2nd Review)

TRANSMITTAL DATE: February 20, 2008

DUE DATE: February 19, 2008

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. This comment has not been fully addressed. It appears that there is a 4.22 difference, clarify. D.S. 2-03.2.4.A Lot 3 the north property line distance appears to be incorrect.

3. This comment has not been addressed. Provide the lot square footage adjacent to the lot number. D.S. 2-03.2.4.B Provide the square footage for each proposed lot on the plat.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\tentativeplat\S07-155tp-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat, site plan and additional requested documents.
02/21/2008 JASON GREEN ENGINEERING REVIEW Denied DATE: February 21, 2008
SUBJECT: Circle K Tentative Plat- 2nd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 3301 S 6th Avenue, T14S R13E Sec25 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: S07-155


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Tentative Plat, Drainage Statement (L.E.A.D.S., Inc., 20AUG07 revised 15JAN08), Geotechnical Investigation Report (Foree&Vann, Inc, 23MAY07 and addendum 13NOV07) and a copy of the Title Report. The Drainage Statement was reviewed for Tentative Plat purposes only. The Tentative Plat is not approved at this time. The following items need to be addressed:


TENTATIVE PLAT: Engineering Division acknowledges that a site plan (T07CM01074) and grading plan (T07BU02153) have been submitted for review and comments will be posted under each activity. Due to the change in drainage design and the removal of the underground retention/drywell system the Tentative Plat has been re-reviewed for compliance with the Development Standards. The site plan and grading plan can not be approved prior to Tentative Plat approval.

1) DS Sec.2-03.2.3.A: Revise the Tentative Plat and the bench mark reference section on Sheet 1 to reference either NGVD29 or NAVD88 datum that was used for the topography, stating "City of Tucson Datum" is not acceptable. Per Section 3.0 of the proposed Drainage Statement the datum reference is NAVD88; Field Book 1981-1, Page 64, verify.

2) DS Sec.2-03.2.3.C: Revise the Tentative Plat to label all easements that are to be abandoned along with the recordation information and a letter from the utility companies stating their approval of the abandonment. Per the proposed grading plan there are electric and utility easements under the foot print of the building that must be abandoned prior to Tentative Plat approval.

3) DS Sec.2-03.2.3.J.1: Revise the Tentative Plat to label the existing 100 discharge for the concentration points located along the northwest and north portion of the property. If the Q100 value is greater than 100 cfs the 100-year water surface elevation must be provided. The Drainage Statement and Exhibits must clearly label all concentration points and discharge values. The Tentative Plat must also label all Q100 discharge values at all proposed concentration points.

4) DS Sec.2-03.2.4.F: Revise the Tentative Plat to label the required 25-foot radii at all access points along 6th Avenue to verify that it is designed in accordance with Street Development Standard 3-01.0. Specifically the north driveway must have both curb returns labeled with 25-foot radii.

5) DS Sec.2-03.2.4.H: Revise the Tentative Plat to be in accordance with the Major Streets and Routes Plan. Clearly label the dimensioned future right-of-way width for 6th Avenue as "Future" in plan view.

6) DS Sec.2-03.2.4.J: Revise the Tentative Plat to show the recordation information for all proposed easements, or state that each easement is to be by Final Plat.

7) DS Sec.2-03.2.4.L: Revise the Tentative Plat, in conjunction with the submitted Drainage Statement, to reflect the following information. For additional information regarding drainage standards, see the City of Tucson Standards Manual for Drainage Design and Floodplain Management.

a) Provide spot elevations at intervals along the proposed basin bottoms to show slope percentage. The bottom of basin slope to the outlet must be 0.5% or greater to prevent accumulation of standing water and mosquito infestation. The Tentative Plat shows the bottom sloped towards the inlet side of the basin, revise.

b) Provide the WSEL for both proposed retention basins in plan view and in a cross section with details. Cross sections of the basin must show side slopes, depths, basin bottom elevation, top elevation, inlet, outlets, etc. Sheet 2 of the Tentative Plat must be revised so that the bottom and headwater elevations match the proposed Drainage Statement. Provide in the legend a clear definition of all abbreviations (i.e. BT- Bottom of Basin, HWE- Headwater Elevation, etc.).

c) Provide a cross section between Basin 1 and 2 to show that the proposed pipe is not in conflict with the proposed maintenance ramp. Verify that the pipe has enough fall so that it is not exposed or in conflict with the 9.92 % ramp slope.

d) Provide a singed notarized agreement from the adjacent property owner for the discharge of the roof down spouts onto the adjacent property. Verification is required when any drainage solution occurring outside the boundaries of individual lots is constructed with adjacent owner's permission, even if the same person owns the property at the time of platting. It is advisable to provide such agreement for City review prior to recordation to verify it meets all requirements.

8) DS Sec.11-01.9: Revise the Tentative Plat to provide the required 2-feet setback from all property boundaries to the proposed limits of grading, fill slopes, retention basin, block wall and any associated erosion protection. The plan view on the Tentative Plat shows that the limits of grading encroach within the required 2-feet setback for the basin along the north property line. Provide sufficient room to allow for the 2-feet setback from property lines to top of fill slopes and associated erosion protection. Provide a cross section for all property boundaries that show the 2-foot setback for all structures from the property line.

9) Revise the Tentative Plat to label and dimension all proposed drainage improvements. Specifically label the proposed pipe from Basin 1 to Basin 2, label and detail all basin outlets, bleed pipes, basin inlets, erosion protects, etc.

10) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications:

a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html /

b) http://www.dot.ci.tucson.az.us/engineering/pia.php

c) Or contact Thad Harvison at 837-6592 for all additional questions regarding r-o-w.


DRAINAGE STATEMENT:

11) Per the results of the geotechnical report and borings it has been shown that the subject property has a slow infiltration rate of 15 hours, this value exceeds the maximum 12-hour time needed. Threshold retention requirements may be waived in certain cases when stormwater retention is not feasible due to constraints imposed by subsurface conditions. In such cases detention criteria may be imposed in lieu of threshold retention requirements. Provide a revised report that addresses the slow infiltration rates in the basin design. Due to the slow infiltration rates Basin 1 must have a designed outlet with a low flow bleed pipe so that water can discharge with out causing standing water within the basin. The proposed emitter system will not function for infiltration purposes.

12) Revise the Drainage Statement to include all drainage improvement structures. The emitter system shown on the grading plan seems to be a type of dry well system that infiltrates water into the subsurface. However per the geotechnical report the infiltration rates do not support the use of such a system. Revise the report to include a discussion to show that the basin drains towards (minimum 0.5 percent slope) an outlet. Provide all details for the basin; outlet, bleed pipe, proposed culvert between the basins, rock riprap, etc.

13) Revise the Exhibits within the Drainage Statement to clearly label all concentration points (existing and proposed) with the corresponding Q100 discharge value. Provide the location for all outlet structures as stated in Section 5.0 of the report.

14) Revise the Tentative Plat so that all basin elevations, water surface elevations, and percent slopes match the proposed drainage statement. Per the Tentative Plat the water surface elevations within the basins differ from the hydraulic calculations shown. The bottom elevations also differ from plan view to the drainage statement, revise.


GRADING PLAN:

15) DS Sec.11-01.2.1: A grading plan permit application (T07BU02153) has been submitted for review and comments will be posted under a separate letter. A grading permit may not be issued prior to Tentative Plat or Site Plan approval.

16) Please ensure the grading plan is consistent with the Tentative Plat, Site Plan, Drainage Statement, and Geotechnical Report. Grading standards may be accessed at http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf.

17) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans and text addressing stormwater controls for all areas affected by construction activities related to this development have been submitted and will be reviewed with the grading plan submittal.


GENERAL COMMENTS:

Provide a revised Tentative Plat and a revised Drainage Statement.

The revised Tentative Plat and Drainage Statement must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Tentative Plat and Drainage Statement.

If you have any questions, I can be reached at (520) 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
02/27/2008 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Denied ADOT has some comments on this review;



* Show access control on the plan
* What facility lies to the west of driveway 'B'?
* Were there any 24 hour counts conducted for the TIA?
* Need a cleaner set of plans, these are too busy.
* Need to review if there will be any modifications needed to the
drainage easement on the north property that may be required by ADOT and
the C of T.

- It will be the responsibility of the developer/contractor to
coordinate with the proposed Curacao project, to the west, and the
current 6thavenue bridge with ADOT to prevent any repeat activities.





If you have any questions or comments, I can be reached at388-4226.
Thank you. TM.

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
02/29/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 29, 2008

Hank Hulbert
Leads & CEI Engineering Associates
2400 North Central Avenue Suite 203
Phoenix, Arizona 85004

Subject: S07-155 Circle K Tentative Plat

Dear Hank:

Your submittal of January 18, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

9 Copies Revised Tentative Plat (Traffic, Wastewater, Landscape, ADOT, Real Estate, ESD, Zoning, Engineering, DSD)

4 Copies Revised Landscape Plan (Landscape, Zoning, Engineering, DSD)

2 Copies Revised Drainage Statement (Engineering, DSD,)





Should you have any questions, please call me at 837-4919.


Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (602) 254-1700