Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: S07-142
Parcel: Unknown

Address:
1052 E EASY ST

Review Status: Completed

Review Details: RESUBMITTAL- RECORD OF SURVEY

Plan Number - S07-142
Review Name: RESUBMITTAL- RECORD OF SURVEY
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/18/2008 ANDY STEUART COT NON-DSD REAL ESTATE Denied The following easements, Dkt./Pg. 13050/799, 13227/217, 13254/13 and 13254/17 were conveyed from Easy Street Investors, LLC, back to the same interest. This could create problems after the proposed parcels transfer. These easements are listed w/in the Title Report, however the title company will not insure these proposed easements.

A "Covenant and Declaration of Easement" form was forwarded to Physical Resources Engineering, Inc., as a suggested remedy.
04/24/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator
DATE: April 24, 2008

SUBJECT: Engineering review of the Easy Street Centro, Record of Survey. The activity
number is S07-142.

SUMMARY: The Record of Survey was received by Engineering. Engineering has reviewed
the received items and does not recommend approval of the Record of Survey.

RESUBMITTAL REQUIRED: RECORD OF SURVEY

RECORD OF SURVEY COMMENTS

1. Complied

2. Complied

3. Complied

4. Complied

5. Complied

6. The Engineering Division's Presubmittal Review documentation states that a 5' sidewalk
is required prior to submittal of the record of survey. The site plan shows in keynote
1; a 5' sidewalk is to be constructed. The sidewalk must be constructed within the
ROW prior to approval of the record of survey. With the next submittal provide documentation
from the Department of Transportation clarifing the sidewalk is constructed. DS 2-03.11.12. Acknowledge statutory performance bond submitted - Bonding company must be able to do business in Arizona. Provide Arizona bonding information. Current bond is for the State of Washington. In addition, original bond will need to be submitted to the City of Tucson for review.

7. Complied

8. Complied

9. Complied

10. Complied

11. Complied
04/25/2008 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review
04/25/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES


April 25, 2008

Daniel White
Physical Resource Engineering, Inc.
P.O. Box 36985
Tucson, Arizona 85740

Subject: S07-142 East Street Centro Record of Survey

Dear Dan:


The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off.

(1) Executed Record of Survey Double Matte Oce or Photo Mylar.
(2) Check made to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee for recording purposes.
(3) Check made to "Reproductions, Inc." in the amount of $2.00 per plat page for CDRC file copy.

The CDRC office will then take your stamped and approved Record of Survey mylar to the Pima County Recorder's Office for recording and after recording a copy will be made for the CDRC file. You will be notified when this has been done to pick up your recorded Record of Survey mylar from the CDRC office and take it to the Pima County Addressing office at 201 North Stone Avenue (across from the CDRC office) for addressing of the site.

PRIOR TO SUBMITTING THE MYLARS TO THE CDRC OFFICE, REAL ESTATE MUST REVIEW AND APPROVE THE MYLARS FOR THE COMMENTS MADE 4/18/2008. WRITTEN APPROVAL FROM REAL ESTATE IS REQUIRED. E-MAIL IS OKAY.

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.cityoftucson.org/dsd

Via fax 690-1669