Plan Number: S07-131
Parcel: Unknown

Address:
9047 S RITA RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S07-131
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/27/2007 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Target Fulfillment Center West
S07-0131
Final Plat

TRANSMITTAL DATE: September 27, 2007

DUE DATE: October 05, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section conditionally approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

2. Zoning is not clear what is happening with the easements that were proposed to be abandoned per the first submittal. On the first submittal there was a "30' ACCESS & PUBLIC UTILITY EASEMENT DKT 12017 PG 6522 TO BE ABANDONED BY SEPARATE INSTRUMENT" shown on sheet 2. There was also a "TEP 10' EASEMENT DKT 6245 PG 618 TO BE ABANDONED BY SEPARATE INSTRUMENT" shown on sheet s 2 & 3. On this submittal the information about "TO BE ABANDONED BY SEPARATE INSTRUMENT" has been removed from the plan. Please clarify if these easements are to be abandoned. If these easements are to be abandoned show them as "EXISTING (description of easement) TO BE ABANDONED PER DKT_____ PG_____". If these easements are to remain than disregard this comment. Provide the recordation information, docket and page, on the plat for the easements that are shown to be abandoned.

3. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C\planning\cdrc\finaplat\S07-131fp-2nd.doc
09/28/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S07-131 TARGET FULFILLMENT CENTER WEST/REVISED FINAL PLAT
DATE: September 28, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:



Delete “South” from Rita Road on sheet 1.

Correct Rita Park Pl to Rita Park Place on sheet 2.

Correct Rita Tech Pl to Rita Park Place on sheet 4 (adjacent to lot 1 and lot 2).

Label Target Way on sheet 3.




jg
09/28/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S07-131 TARGET FULFILLMENT CENTER WEST/REVISED FINAL PLAT
DATE: 10/11/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***


ES
10/04/2007 MATT FLICK ENGINEERING REVIEW Approv-Cond The plat will be approved upon approval of the assurances.
10/05/2007 FRODRIG2 COT NON-DSD REAL ESTATE Approved No comment
10/05/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approved August 03, 2007

To: Ken Perry, EEC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Eng. Manager
Development Review Division ( Wastewater)
Pima County Development Services Department

Subject: Interstate Commerce Park, Lots 1 through 12
Final Plat – 2nd Submittal
S07-131

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat received by us on September 21, 2007.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above comments, please do not hesitate to contact me.

Sincerely,


Chandubhai C. Patel, P.E.
520-640-6563

CC: Project File
10/08/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 8, 2007

Ken Perry
Engineering & Environmental Consultants, Inc. (EEC)
4625 East Fort Lowell Road
Tucson, Arizona 85712

Subject: S07-131 Target Fulfillment Center Final Plat

Dear Ken:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge.
(1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page.
(1) Executed and notarized CC&R's document (if applicable).

*Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

THE FINAL PLAT MYLARS MUST BE REVIEWED AND APPROVED BY PIMA COUNTY ADDRESSING PRIOR TO SUBMITTAL TO THE CDRC OFFICE. APPROVAL MUST BE IN WRITING (E-MAIL IS OKAY).

THE FINAL PLAT MYLARS MAY NOT BE SUBMITTED UNTIL THE TENTATIVE PLAt (D07-0028) HAS BEEN APPROVED.

Should you have any questions, please call me at 837-4919.


Sincerely,




Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/