Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S07-121
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S07-121
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/23/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/24/2009 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Joyce Hays, Section Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: 04/24/09


RE: Assessor’s Review and Comments Regarding Final Plat Casa Del Pueblo, S07-121, Sec 01, T15S, R13E.


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

x Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS: Thank you for your submittal.
Brian Sloan
Pima County Assessor’s Office
740-4395

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
04/27/2009 JASON GREEN ENGINEERING REVIEW Denied DATE: April 27, 2009
SUBJECT: Casa Del Pueblo Final Plat- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 4975 S Liberty Avenue, T15S R13E Sec01 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: S07-121 (Final Plat)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted Final Plat, recorded Pueblo Senior Housing Phase I and Phase II Shared Use Agreement (Docket 13180, Page 2079) and a copy of the Title Report. The Final Plat is not approved at this time. The following items need to be addressed:


FINAL PLAT COMMENTS:

1) DS Sec.2-03.6.1.J: Revise Sheet 2 of the Final Plat to remove all of the non survey related information (building layout, refuse containers, topography, PAALs, sidewalks, ramps, scuppers, etc). The Final Plat should only show information that is related to survey lines, property lines, easements, etc. Refer to DS Sec.2-03 for all Final Plat requirements.

2) DS Sec.2-03.6.3.A: Revise the Certification of Survey Section to read per the Development Standards; "I hereby certify that the boundary survey as shown on this plat was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this plat was prepared under my direction."

3) DS Sec.2-03.6.3.A: For Final Plat approval the Certification of Survey Section must be sealed and signed by the Surveyor of Record prior to Mylar submittal. The signature for the civil seal that is shown is not required since this project does not have floodplain information, erosion hazard setback lines, detention/retention basins, etc. Only the Surveyor who prepared the plat must sign and seal the document.

4) DS Sec.2-03.6.3.D: Revise the Approval Block per the following; "I, ROGER W. RANDOLPH, CLERK OF THE CITY OF TUCSON, ARIZONA, HEREBY CERTIFY THAT THIS PLAT WAS APPROVED BY THE MAYOR AND COUNCIL OF THE CITY OF TUCSON, ARIZONA, ON THIS _______ DAY OF ________, 20__." Revise the signature line to include the same name as above.

5) DS Sec.2-03.6.3.E: Revise the Assurance paragraph to read per the referenced section and Department Directive;
_____________________________________________
City of Tucson Development Services Department Director
_________________________________________________________
City of Tucson Development Services Department Engineering Administrator

6) DS Sec.2-03.6.4.I: Revise Sheet 2 of the Final Plat to clearly show the survey lines proposed around the water harvesting area. Remove all other lines associated with these basins such as the topography.

7) DS Sec.2-03.6.5.C.1: Revise the Basis of Bearing Note (General Note # 10) so that the basis of bearing is established from 2 found, physically monumented points described and shown on the final plat. If the monuments at each end of the reference line are fully described on the plat they need not be described in the "Basis of Bearing" statement or note.

8) DS Sec.2-03.6.5.C.4.a: Revise the Final Plat so that all new proposed boundary monumentation is labeled as "set." A one-half (½) inch iron rod tagged by a registered land surveyor must be shown on the Final Plat at all proposed property corners and are to be set upon completion of construction.

9) DS Sec.2-03.6.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between monuments were measured or calculated for all property line boundary information.

10) DS Sec.2-03.7.1.G: The Final Plat cannot be scheduled for Mayor and Council consideration until Financial Assurances are submitted and approved. The Final Plat Dedication Paragraphs must be revised to reflect the type of Assurances proposed, i.e. bond, letter of credit, or 3rd Party Trust that would require a Beneficiary Section.


GENERAL COMMENTS:

Provide a revised Final Plat and Assurance Package at resubmittal. The revised Final Plat must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Final Plat and Assurance Package.

If you have any questions, I can be reached at (520) 837-4929.




Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
04/30/2009 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
04/30/2009 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: S07-121 CASA DEL PUEBLO/FINAL PLAT
DATE: 4/29/09



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Delete all owner information.
Change all Bk 3, Pg 42 to Pg 41.
05/12/2009 ANDY STEUART COT NON-DSD REAL ESTATE Approv-Cond Comments for Real Estate Program are provided 5/12/09, by Andy Steuart, Property Agent, (520 791-4181.

Note: Kevin Hall confirmed that Casa del Pueblo II will acquire Lot 2 when Final Plat is adopted by Mayor and Council.

To Sht. 1 of 2, the following is requested:
-Under Approval, change the name of City Clerk to Roger Randolph.
-Change "Legal Description - Proposed Parcels" to "Legal Descriptions Lot 1 and Lot 2"
05/18/2009 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: CASA DEL PUEBLO
S07-121

Tucson Electric Power Co. (TEP) approves the final plat submitted April
23, 2009. Should easements be required to service this development,
those easements will be secured by separate instrument.
Please forward any resubmittals of the final plat to this office.

Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent II
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
05/19/2009 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S07-121
Casa Del Pueblo, Lots 1 and 2
Final Plat

TRANSMITTAL DATE: May 18, 2009

DUE DATE: May 20, 2009

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 11/20/2009.

2. Darken the text of both plans sheets. The text is very light and not very legible. DS 2-03.6.1.C

3. Darken up the line work a bit to ensure legibility. DS 2-03.6.1.J

4. Under the approval text block fill in the city clerks name as follows: Roger W. Randolph. Replace the city clerks name to Roger W. Randolph above the words Clerk, City of Tucson. DS 2-03.6.3.D

5. Show no-vehicular access easements where applicable. DS 2-03.6.4.H

6. Clarify if there will any type of CC&R's for this development. IF so please provide a copy with the next submittal of the final plat. DS 2-03.6.6

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\finalplat\S07121fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and if applicable, copies of the CC&R's
05/20/2009 FERNE RODRIGUEZ COT NON-DSD TUCSON AIRPORT AUTHORITY Approved To Whom It May Concern:

Thank you for the opportunity to comment on S07-121 Casa Del Pueblo, a
final plat review application for approximately 4 acres located south
and west of the southwest corner of Old Nogales Hwy and Irvington. This
site is within the Tucson International Airport public disclosure area.
The applicant has provided initial documentation that an avigation
easement for the site has been recorded.

The Tucson Airport Authority does not oppose this application.

Please contact me if you have any questions or concerns.

Respectfully,


Jordan D. Feld, AICP

Director of Planning

Tucson Airport Authority

7005 S. Plumer Ave.

Tucson, AZ 85756

jfeld@tucsonairport.org

www.tucsonairport.org

(520) 573-5115 office

(520) 573-8006 fax
05/21/2009 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Approv-Cond May 20, 2009


To: Dennis Knudsen
Knudsen-Smith Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Eng. Manager
Development Review Division (Wastewater)

Subject: Casa Del Pueblo , Lots 1 and 2
FinalPlat – 1st Submittal
S07-121



The drawings of the final plat for this project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (RWRD). The following comments are offered for your use:

General: The quality of the drafting of this drawing is bad in that the letters are very light. They need to be dark enough so that when microfilmed should be easily legible. We need a good copy of these drawings.

SUBJECT TO THE ABOVE, the PDEQ and the RWRD hereby approve the above referenced submittal of the Final Plat received on 4/22/09.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above comments, please do not hesitate to contact me.






Tom Porter , Sr CEA
05/28/2009 JWILLIA5 ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 28, 2009

Kevin Hall
DCC Company
2828 N. Country Club, #100
Tucson, Arizona 85716

Subject: Casa Del Pueblo (S07-121) Final Plat Re-submittal

Dear Kevin:

Your submittal of April 22, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 4 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Final Plat (Zoning, Engineering, Addressing, DSD)

2 Copies Boundary Closure Calculations (Engineering, DSD)

2 Copies CC&R's (Zoning, DSD)

2 Copies Assurances (Engineering, DSD)

Should you have any questions, please call me at 837-4919.


Sincerely,




Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (520) 829-7856