Plan Number: S07-101
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S07-101
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/26/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/31/2009 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: RIVERFRONT PLAZA
S07-101

Tucson Electric Power Co. (TEP) approves the final plat submitted for
review August 26, 2009.
Please forward any resubmittals of the final plat to this office.

Please contact me at (520) 917-8745 if you have any questions.

Liza Castillo, Right of Way Agent II
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
09/04/2009 ELIZABETH LEIBOLD ENGINEERING REVIEW Approv-Cond TO: Patricia Gehlen; CDRC Manager
FOR: Michael York, RLS
SUBJECT: Riverfront Plaza Final Plat 2nd submittal Engineering Review
LOCATION: T14S R13E Section 35, 119-42-009C
REVIEWER: Elizabeth Leibold, PE
ACTIVITY NUMBER: S07-101

SUMMARY: The revised Final Plat, title report, and a copy of revised unsigned CC&R's were received by Engineering. Engineering has reviewed the received items and does not recommend approval of the Final Plat at this time. Conditional approval may be provided if assurable comment is addressed prior to 10SEP09. Address the remaining Final Plat and CC&R comments:

FINAL PLAT COMMENTS:
1) DS Sec.2-03.7.1.G, DS Sec.2-03.6.3.E: Financial assurances are generally required to be submitted as part of the final plat submittal. Exceptions to this requirement will be allowed if, in these instances, the City Engineer's Office is advised that the final plat submittal does not include the assurances. However, assurances must be submitted to the City Engineer's Office some time during this review phase. The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office. Verification of assurable items is required prior to approval of the final plat. If the improvements are not all completed, assurances will be required. Although there were PIA, Water, and PCWW approvals, access is an assurable item. Per inspector's report 2SEP09, the outstanding access items include required pedestrian access for lot 3 to pedestrian connection north of Lot 1. Submit estimate to Engineering Reviewer for acceptance of assurance amount prior to obtaining bond or other security.
2) DS Sec.2-03.6.1.J: Line weights will reflect the nature of the line, e.g., boundary lines will be more prominent than lot lines. Revise legend on sheet 2.
3) DS Sec.2-03.6.6.A: Address the remaining CC&R comments:
a) Provide exhibits A, B, & C.
b) Provide clarification of maintenance for sidewalk area adjacent to Irvington Road, per PIA approval letter. Provide page number in response letter for reference to any cross access agreement or easement in the CC&R's. It will be necessary to provide on the Final Plat, one of the following: a general note for a cross access agreement, or, a note for cross access easement reference to CC&R's and easement drawn on planview, or, revised lot lines for PAAL between lots 2 & 3.
c) Please add subdivision case number (S07-101) to the CC&R's. This is preferred on the cover / first page next to or below Riverfront Plaza.
d) An original signed copy of the CC&R's with all pages numbered will be required for Final Plat approval.

Submit the revised Final Plat, revised CC&R's, and a copy of the title report with resubmittal. If you have any questions, please call me at 837-4934.

Elizabeth Leibold, PE
Civil Engineer
Engineering Division
Planning & Development Services Dept
09/04/2009 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Riverfront Plaza Lots 1, 2, 3 & 4
S07-101
Final Plat

TRANSMITTAL DATE: September 4, 2009

DUE DATE: September 10, 2009

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section conditionally approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

2. This comment was not addressed. The title block for the CC&Rs should read Riverfront Plaza, Lots 1, 2, 3, 4 and common Area A (Parking, Drive Lanes, Landscaping, & Utilities) and B (Detention Basin) D.S. 2-03.6.6 The Title of the Declaration of Covenants, Conditions and Restrictions should match the title block shown on the plat. This should include a letter designation for the common area.

3. Per a discussion with the design engineer a general note will be added to the final plat in regards to pedestrian and vehicle access. The note should state "CROSS ACCESS ACROSS LOTS 1, 2 & 3 FOR VEHICULAR ACCESS, PEDESTRIAN ACCESS AND PARKING SHALL BE PROVIDED PER THIS PLAT'.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C\planning\cdrc\finaplat\S07-101fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
09/04/2009 ELIZABETH LEIBOLD ENGINEERING REVIEW Approv-Cond DATE: September 4, 2009
TO: Patricia Gehlen; CDRC Manager
FOR: Michael York, RLS
SUBJECT: Riverfront Plaza Final Plat 2nd submittal Engineering Review
LOCATION: T14S R13E Section 35, 119-42-009C
REVIEWER: Elizabeth Leibold, PE
ACTIVITY NUMBER: S07-101

SUMMARY: The revised Final Plat, title report, and a copy of revised unsigned CC&R's were received by Engineering 27AUG09. Engineering reviewed the CC&R's at the counter with applicant to go over pedestrian access assurance comments. Engineering reviewed the received items and changes recommendation from denial to conditional approval of the Final Plat & CC&R's with the remaining minor comments.

FINAL PLAT COMMENTS:
1) DS Sec.2-03.6.1.J: Line weights will reflect the nature of the line, e.g., boundary lines will be more prominent than lot lines. Revise legend on sheet 2.
2) DS Sec.2-03.6.6.A: Address the remaining CC&R comments:
a) Provide exhibits A, B, & C.
b) Please add subdivision case number (S07-101) to the CC&R's. This is preferred on the cover / first page next to or below Riverfront Plaza.
c) An original signed copy of the CC&R's with all pages numbered will be required for Final Plat approval.

Submit the revised Final Plat mylar, revised CC&R's, and a copy of the title report with resubmittal. If you have any questions, please call me at 837-4934.

Elizabeth Leibold, PE
Civil Engineer
Engineering Division
Planning & Development Services Dept
09/09/2009 PGEHLEN1 CC&R CC&R's Approv-Cond see engineering comments
09/10/2009 JWILLIA4 ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 10, 2009


Richard Cordova
DOWL HKM
166 W. Alameda St.
Tucson, Arizona 85701

Subject: S07-101 Riverfront Plaza Final Plat

Dear Richard:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * 81/2"X11" copy of plat
(1) * Check in the amount of $20.00 per plat page for recorded plat distribution made payable to the local print company that has access to Pima County Recorders on line platting system or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page and fees for consent(s) to dedicate, if applicable.
(2) Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). One original set and one copy of each.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Should you have any questions, please call me at 837-4919.



Sincerely,





John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: (520) 624-0384