Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S07-101
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/26/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
08/31/2009 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: RIVERFRONT PLAZA S07-101 Tucson Electric Power Co. (TEP) approves the final plat submitted for review August 26, 2009. Please forward any resubmittals of the final plat to this office. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent II Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
09/04/2009 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approv-Cond | TO: Patricia Gehlen; CDRC Manager FOR: Michael York, RLS SUBJECT: Riverfront Plaza Final Plat 2nd submittal Engineering Review LOCATION: T14S R13E Section 35, 119-42-009C REVIEWER: Elizabeth Leibold, PE ACTIVITY NUMBER: S07-101 SUMMARY: The revised Final Plat, title report, and a copy of revised unsigned CC&R's were received by Engineering. Engineering has reviewed the received items and does not recommend approval of the Final Plat at this time. Conditional approval may be provided if assurable comment is addressed prior to 10SEP09. Address the remaining Final Plat and CC&R comments: FINAL PLAT COMMENTS: 1) DS Sec.2-03.7.1.G, DS Sec.2-03.6.3.E: Financial assurances are generally required to be submitted as part of the final plat submittal. Exceptions to this requirement will be allowed if, in these instances, the City Engineer's Office is advised that the final plat submittal does not include the assurances. However, assurances must be submitted to the City Engineer's Office some time during this review phase. The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office. Verification of assurable items is required prior to approval of the final plat. If the improvements are not all completed, assurances will be required. Although there were PIA, Water, and PCWW approvals, access is an assurable item. Per inspector's report 2SEP09, the outstanding access items include required pedestrian access for lot 3 to pedestrian connection north of Lot 1. Submit estimate to Engineering Reviewer for acceptance of assurance amount prior to obtaining bond or other security. 2) DS Sec.2-03.6.1.J: Line weights will reflect the nature of the line, e.g., boundary lines will be more prominent than lot lines. Revise legend on sheet 2. 3) DS Sec.2-03.6.6.A: Address the remaining CC&R comments: a) Provide exhibits A, B, & C. b) Provide clarification of maintenance for sidewalk area adjacent to Irvington Road, per PIA approval letter. Provide page number in response letter for reference to any cross access agreement or easement in the CC&R's. It will be necessary to provide on the Final Plat, one of the following: a general note for a cross access agreement, or, a note for cross access easement reference to CC&R's and easement drawn on planview, or, revised lot lines for PAAL between lots 2 & 3. c) Please add subdivision case number (S07-101) to the CC&R's. This is preferred on the cover / first page next to or below Riverfront Plaza. d) An original signed copy of the CC&R's with all pages numbered will be required for Final Plat approval. Submit the revised Final Plat, revised CC&R's, and a copy of the title report with resubmittal. If you have any questions, please call me at 837-4934. Elizabeth Leibold, PE Civil Engineer Engineering Division Planning & Development Services Dept |
09/04/2009 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Riverfront Plaza Lots 1, 2, 3 & 4 S07-101 Final Plat TRANSMITTAL DATE: September 4, 2009 DUE DATE: September 10, 2009 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 2. This comment was not addressed. The title block for the CC&Rs should read Riverfront Plaza, Lots 1, 2, 3, 4 and common Area A (Parking, Drive Lanes, Landscaping, & Utilities) and B (Detention Basin) D.S. 2-03.6.6 The Title of the Declaration of Covenants, Conditions and Restrictions should match the title block shown on the plat. This should include a letter designation for the common area. 3. Per a discussion with the design engineer a general note will be added to the final plat in regards to pedestrian and vehicle access. The note should state "CROSS ACCESS ACROSS LOTS 1, 2 & 3 FOR VEHICULAR ACCESS, PEDESTRIAN ACCESS AND PARKING SHALL BE PROVIDED PER THIS PLAT'. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C\planning\cdrc\finaplat\S07-101fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents. |
09/04/2009 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approv-Cond | DATE: September 4, 2009 TO: Patricia Gehlen; CDRC Manager FOR: Michael York, RLS SUBJECT: Riverfront Plaza Final Plat 2nd submittal Engineering Review LOCATION: T14S R13E Section 35, 119-42-009C REVIEWER: Elizabeth Leibold, PE ACTIVITY NUMBER: S07-101 SUMMARY: The revised Final Plat, title report, and a copy of revised unsigned CC&R's were received by Engineering 27AUG09. Engineering reviewed the CC&R's at the counter with applicant to go over pedestrian access assurance comments. Engineering reviewed the received items and changes recommendation from denial to conditional approval of the Final Plat & CC&R's with the remaining minor comments. FINAL PLAT COMMENTS: 1) DS Sec.2-03.6.1.J: Line weights will reflect the nature of the line, e.g., boundary lines will be more prominent than lot lines. Revise legend on sheet 2. 2) DS Sec.2-03.6.6.A: Address the remaining CC&R comments: a) Provide exhibits A, B, & C. b) Please add subdivision case number (S07-101) to the CC&R's. This is preferred on the cover / first page next to or below Riverfront Plaza. c) An original signed copy of the CC&R's with all pages numbered will be required for Final Plat approval. Submit the revised Final Plat mylar, revised CC&R's, and a copy of the title report with resubmittal. If you have any questions, please call me at 837-4934. Elizabeth Leibold, PE Civil Engineer Engineering Division Planning & Development Services Dept |
09/09/2009 | PGEHLEN1 | CC&R | CC&R's | Approv-Cond | see engineering comments |
09/10/2009 | JWILLIA4 | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 10, 2009 Richard Cordova DOWL HKM 166 W. Alameda St. Tucson, Arizona 85701 Subject: S07-101 Riverfront Plaza Final Plat Dear Richard: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: (2) Title reports current within the last thirty (30) days. (1) Executed Final Plat Double Matte Océ or Photo Mylar. (1) * 81/2"X11" copy of plat (1) * Check in the amount of $20.00 per plat page for recorded plat distribution made payable to the local print company that has access to Pima County Recorders on line platting system or provide an account number to charge. (1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page and fees for consent(s) to dedicate, if applicable. (2) Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). One original set and one copy of each. Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval. Should you have any questions, please call me at 837-4919. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 624-0384 |