Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S07-085
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 01/21/2010 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Approved | No comment. |
| 01/22/2010 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Sherry Hyde Senior Property Technician Pima County Assessor’s Office DATE: January 21, 2010 RE: Assessor’s Review and Comments Regarding S07-085 BLUE SKY SUBDIVISION: RESUBMITTAL- FINAL PLAT * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: THANK YOU FOR YOUR SUBMITTAL. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 01/27/2010 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 01/29/2010 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approv-Cond | SUBJECT: BLUE SKY SUBDIVISION S07-085 Tucson Electric Power Co. (TEP) conditionally approves the final plat submitted for review January 19, 2010. The key note number 7 on sheet 2 (10.00' x 10.00' TEP Easement by this plat) is incorrectly labeled as number 15 and should be changed to number 7. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please forward any resubmittals of the final plat to this office. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent II Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
| 02/10/2010 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 2ND FL TUCSON, AZ 85701-1207 AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: S07-085 BLUE SKY SUBDIVISION/FINAL PLAT DATE: 02/10/10 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County's Geographic Information System. Your support is greatly appreciated.*** |
| 02/16/2010 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Blue Sky Subdivision Final Plat Engineering Resubmittal Review REVIEWER: Elizabeth Leibold, PE LOCATION: T15S R14E Section 6 ACTIVITY NUMBER: S07-085 SUMMARY: The revised Final Plat package including revised plat sheets, revised CC&R's, assurances, title report schedule, and response letter was received by Engineering for Final Plat review. Engineering does not recommend approval of the Final Plat at this time. Please address the following comments for resubmittal. ASSURANCE COMMENTS: 1) City of Tucson Development Standards (DS) Section No.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. For third party trust subdivision assurances, address the remaining assurance comments: a) Assure that the Subdivision name is updated from Tucson Urban League Incorporated to Blue Sky … on the first page of the AGREEMENT TO CONSTRUCT (Paragraph A) and AMENDMENT TO TRUST (Paragraph 1). The name of the subdivision should match the Title block on the plat. b) Provide full copy of assurance documents (same as this submittal). 2) Assure that the descriptions of the common areas of the Final Plat title block match the CC&R's descriptions of the subdivision common areas and the descriptions in the assurance paperwork. Please be aware that the legal office may reject the assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block. FINAL PLAT COMMENTS: 3) DS Sec.2-03.6.4.G: Corner lots may be designated with a star symbol indicating which street will be used for access (lots 1, 23, 24,& 42). Use of this designation may limit design options for access. 4) DS Sec.2-03.6.5.C: Address the remaining survey related comments: a) Not one corner of the plat is tied to a section corner; at least 1 corner of the subdivision will be tied by course and distance to SW corner section 6. b) Address the remaining boundary comments: i) Provide labelings for all marked survey monuments on Final Plat; additional marked monuments are indicated on submitted exhibit. 5) DS Sec.2-03.6.5.B: Assure that all easements listed on the Schedule B of title report are clearly drawn, labeled with Book/page or Docket/page, and/or listed as a blanket easement, and/or labeled with accurate dimensions and bearings on the plat. In response letter, please state whether / how items 9 & 11 of the updated Schedule B are addressed / shown on the plat. 6) Address the following drainage easement comments: a) The 3 outlets that were approved per the Tentative Plat, need to be called out as Private Drainage Maintenance Easements that will be maintained by the Blue Sky subdivision HOA. Add a note tot eh final Plat clarifying this responsibility. b) The drainage system that runs from south side of the subdivision and outlets at the north side into the wash, will need to be labeled as "Flowage and Private Drainage Maintenance Easement"; c) The grade control structures in the wash that will be constructed under the PIA by Blue Sky, need to be noted on the Final Plat as being maintained by the City; 7) Off site drainage easements do not need to be shown on this Final Plat; they will be required for grading plans and PIA plans. The next submittal should address all the above items. Submit revised Final Plat, assurance documents, title report, a copy of the final Drainage Report with CD, and response letter. Prior to resubmittal, you are welcome to schedule a meeting with me to go over your comments. If you have any questions, please call me at 837-4934. Elizabeth Leibold, PE, CPM, CFM Civil Engineer Engineering Division Planning & Development Services |
| 02/19/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES February 19, 2010 John Lupo Grenier Engineering, Inc. 5517 E. 17th Street Tucson, Arizona 85711 Subject: S07-085 Blue Sky Subdivision Final Plat Dear John: Your submittal of October 27, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 2 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Final Plat (Engineering, PDSD) 2 Copies Final Drainage Report w/ CD (Engineering, PDSD) 2 Copies Title Report (Engineering, PDSD) 2 Copies Assurances (Engineering, PDSD) 2 Copies CC&R's (Engineering, PDSD) Should you have any questions, please call me at 837-4917. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 326-7508 |
| 02/19/2010 | PGEHLEN1 | CC&R | CC&R's | Denied | See Engineering comments. |