Plan Number: S07-034
Parcel: Unknown

Address:
855 E DREXEL RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S07-034
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/25/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approved July 25, 2007

To: Joaquin Rincon
Civil Works Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter, Sr. Civil Eng. Assistant (520-740-6706), representing the Pima County
Departments of Wastewater Management and Environmental Quality


Subject: Colonia Mariposa, Lots 1-16 & Common Areas A, B-1 - B-16 & C-1 - C-2
Tentative Plat – 2nd Submittal
S07-034

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative or preliminary plat as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please do not hesitate to contact me.
CC: Project file
08/09/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
08/24/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Colonia Mariposa (S04-166) 5th Submittal Tentative Plat Engineering Review
LOCATION: T15S R14E Section 6
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S07-034

SUMMARY: The revised Tentative Plat sheets, revised Drainage Report, landscape documents, a title report, perc tests, and a response letter were received by Engineering for review. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering recommends a conditional approval of the Tentative Plat.

DRAINAGE REPORT COMMENTS / CONDITIONS OF APPROVAL:
1) City of Tucson Development Standards (DS) Section No.10-02.1.5.1: Add to the drainage report that the project is within a balanced basin management area.

TENTATIVE PLAT COMMENTS / CONDITIONS OF APPROVAL:
2) DS Sec.2-03.2.4.L.4: Dimension leaders near lot 6 and drainage easement for clarification on the Tentative Plat.
3) DS Sec.2-03.2.4.L.4: For the general / typical lot detail clarify minimum flow grade around building pads for lots 1-9. Minimum grade shall match geotechnical report recommendations or at minimum building codes of 5% for 10-ft from building.
4) DS Sec.2-03.2.3.C: State whether the title report schedule B item 10 affects the project and show on planview. If the easement overlaps proposed lots a revised layout may be required.
5) Identify basin access ramp on Landscape plan. Access ramp may not be located at scupper locations.
6) Revise call out for slope treatment on Landscape plans to indicate the river rock to have filter fabric. The note indicates filter fabric at basin bottom - provide engineer's explanation of the use of filter fabric at basin bottom - or remove filter fabric at basin bottom.
7) Submit response letter for each comment for resubmittal.

A meeting to go over comments is required prior to next resubmittal. Provide complete response letter with revised Tentative Plat, revised Drainage Report, revised landscape plans, and a copy of the geotechnical report that includes setback recommendations at resubmittal. You may call to go over these comments, or to set up the meeting or if you have any questions, please call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
08/24/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Colonia Mariposa (S04-166) Submittal Tentative Plat Engineering Review
LOCATION: T15S R14E Section 6
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S07-034

SUMMARY: The revised Final Plat package including a copy of the revised Final Plat, copy of the CC&R's, copy of the title report schedule B with updated sewer easement information were received by Engineering for review. Project representative came in to discuss the conditions of the last review and a separate submittal of the Drainage Report was submitted. The Drainage Report and Tentative Plat conditions of approval were accepted by Engineering for Tentative Plat purposes and recommends approval of the Tentative Plat. The Final Plat review comments will be posted this week. Assurances may be submitted with second submittal of the Final Plat package. If you have any questions, please call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
08/27/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

August 27, 2007

Larry Potter
Southern Arizona Land Trust Inc.,
P.O. Box 57370
Tucson, Arizona 85732

Subject: S07-034 Colonia Mariposa Tentative Plat

Dear Larry:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off:

1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO,
2 CD that contains all of the drainage/hydrology and other reports submitted fo the review and approval of this plan.

Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3.

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 325-1208
tp-approved