Plan Review Detail
Review Status: Completed
Review Details: REVISION - TENT PLAT & CORE RESUB
Plan Number - S07-033
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/26/2016 | KROBLES1 | START | PLANS SUBMITTED | Completed | |
| 08/15/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/15/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Reqs Change | DATE: August 16, 2016 DUE DATE: August 23, 2016 SUBJECT: Star Pass Vistas Village 2 TO: Rick Engineering LOCATION: 710 S Greesewood REVIEWERS: Paul Baughman, PE, CFM ACTIVITY: S07-033 SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed: 1) Per Section 7.6.5 of the Drainage Standards Manual (UDC 7.14.4) please show drainage swales for upstream flows where newly proposed pads are blocking the natural flow path. Per AM 2-06.4.9O please also show 10 foot building setback limits from the 100-year flow limits per the above cited drainage standard for flows less than 100 cfs. Some areas of concern are upstream of lots 7, 24, 25, 29, 37 and 38. This may be done with keynote 8 which calls out a 10' building setback from the high water elevation. Please see Section 2.3.1.4C, item 2 of the City of Tucson Drainage Manual (UDC 7.14.4) for requirements on showing drainage flow paths for flows less than 100 cfs. 2) At lots 29 and 30 where pad grades are now shown there are a couple of upstream concentration points where 27 cfs and 37 cfs look like they may be diverted to the 2 smaller 24" SRP instead of the 2 larger 36" SRPs as shown on sheet 3. Please provide design for appropriately sized culverts for conveyance of storm water flows around pads and under driveways per Section 2.1 of the City of Tucson Drainage Standards Manual (UDC 7.14.4). 3) Per AM 2-06.4.9N4 show proposed spot grades on each lot that will provide unimpeded drainage. 4) Per AM 2-06.4.9N3 please show the proper pipe culvert sizes under any proposed vehicular access points that service individual lots to convey drainage under driveways. 5) Per Section 2.3.1.4C1 of the Drainage Standards Manual please show Water surface elevations at the upstream edge of each proposed pad to allow finished floor elevations to be verified against the upstream water surface elevation. See also section 2.1 of the drainage standards manual (ie. The purpose of the drainage report is to determine the FFEs) 6) Per Tucson Code Chapter 26-5.2(3) please show how the placement of fill proposed on lot 24 within the flow area of the 93 cfs to 99 cfs wash does not adversely impact the downstream floodplain limits or the right of way (ie. does not divert flow to right-of-way). See also AM 2-06.4.9N5 for regulations regarding impacts to adjacent properties. Since a fill pad is being proposed on lot 24 as part of this revision, an impact analysis is required (at this time) per previous meeting with PDSD staff regarding this subdivision. Section 4.1 and 4.2 of the drainage report should be reviewed and potentially updated regarding impacts. The concern is the fill pad and structural footprint are shown completely filling the flowline of the 93 to almost 100 cfs flow. The likely point of diversion would be the right-of-way. Please note that the floodplain limits shown downstream are about 50 feet wide. The proposed encroachment of fill into the low flow channel is less than 50 feet from the right of way limits. 7) Fill is being proposed on Lot 14 in both the Erosion hazard setback and encroaching onto both adjacent lots. Since this fill presumably provides support to the structure please provide appropriate analysis and erosion protection design per Section 8.4 of the drainage standards manual to prevent the wash from undermining the fill pad in the future. 8) Per TSM 2-01.9.3 the fill slopes shall not be closer than 2' feet to the lot lines. Please update plans accordingly. If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov. |
| 08/22/2016 | JOE LINVILLE | NPPO | REVIEW | Approved | |
| 08/22/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 08/24/2016 | AHINES2 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All items requested by review staff 3) All items needed to approve these plans |