Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S07-033
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/07/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/19/2008 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The Landscape Section recommends approval subject to the following condition: The Protected Riparian Area is to be documented in a surveyable manner on the final plat and must include the required disclosure note. |
| 04/01/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: S07-033 Starr Pass Vistas Village II Tentative Plat TRANSMITTAL DATE: April 1, 2008 DUE DATE: April 4, 2008 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Once the overlay application has been reviewed and approved by Engineering and Landscaping zoning can approve. The tentative plat cannot be approved until the special application is approved. If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
| 05/20/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | TO: Patricia Gehlen; CDRC Coordinator Consultant: RICK Engineering SUBJECT: Starr Pass Vistas Village 2 Tentative Plat Engineering 2nd Resubmittal Review REVIEWER: Elizabeth Eberbach LOCATION: T14S R13E Section 16 ACTIVITY NUMBERS: S07-033, T08SA00089 SUMMARY: The revised Tentative Plat sheets, revised Drainage Report, boundary closure calculation paperwork, schedules of title report, lot 17 concept plan, response letters, geotechnical engineering report with addenda, and HDZ application and ACS calculation were received by Engineering for review. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering recommends approval of HDZ and ERZ Overlays for Starr Pass Village 2. Engineering recommends conditional approval of the Tentative Plat. CONDITIONS OF APPROVAL: 1) DS Sec.2-03.2.4.L.2: Some FFE's are shown too low; check minimum proposed finished floor elevations for lots 3, 7, 8, 10, 14, 15, 16, 17, 23, 24, 42, and 43 to assure they meet minimum FFE floodplain requirements adjacent to washes. Check/revise exhibit Figure 5 minimum FFE Required table to assure the correct WSEL is used to determine min FFE's. 2) DS Sec.11-01: For detail B/5, since this is a custom graded lot subdivision the word "minimum" should be used to clarify that the houses are not set at 6 feet but may not go closer than 6 feet from property line. 3) Provide hatching for Natural Open Space in legend on first sheet of Tentative Plat. 4) LUC Sec.2.8.1: Update General Note 28. 5) Check/correct the percent disturbance area on sheet 1 of ERR Report-plan. OTHER CONSIDERATIONS: 6) A final Drainage Report in CD form will be required to be submitted at Grading Plan or Final Plat review stage for archiving. Drainage response letters shall be added to the verbiage in the drainage report or added as a registrant's sealed letter. Per AzBTR, the registrant shall mark the CD copy of the professional document: "Electronic copy of final document; sealed original document is with (identify the registrant's name and registration number) 7) For Final Plat, boundary data will need to match title report exhibit, and bearings and distances shall be clarified as recorded, measured or calculated. 8) Contact Fire Department regarding application for fire box for proposed gate. An application will be enclosed with the grading plan package. Address conditions 1-5 for Tentative Plat resubmittal. Submit revised Tentative Plat, a bound copy of the geotechnical report with any addenda, revised Drainage Report, revised ERR plans, and response letter. Prior to resubmittal, you may schedule a meeting with me to go over your conditions. If you have any questions, please call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 05/20/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | DATE: October 10, 2008 TO: Patricia Gehlen; CDRC Coordinator CONSULTANT: RICK Engineering SUBJECT: Starr Pass Vistas Village 2 Tentative Plat Engineering Mylar Resubmittal Review REVIEWER: Elizabeth Eberbach LOCATION: T14S R13E Section 16 ACTIVITY NUMBERS: S07-033, T08SA00089 SUMMARY: The revised Tentative Plat mylar sheets, were received by Engineering for review. Revised Minimum FFE's are accepted. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering recommends approval of HDZ and ERZ Overlays for Starr Pass Village 2. Engineering recommends approval of the Tentative Plat. If you have any questions, please call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 05/28/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S07-033 Starr Pass Vistas Village II (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Starr Pass Vistas Book 58, Page 20 NEIGHBORHOOD PLAN: Tumamoc Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 03/31/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X) Resubmittal Required: (X) Tentative Plat () Development Plan (X) Landscape Plan () Other REVIEWER: msp 791-4505 DATE: 03/31/08 Department of Urban Planning and Design (DUPD) S07-033, Starr Pass Vistas Village II: Tentative Plat Review March 31, 2008 Below are pending staff comments carried over from staff's previous review (12/17/07). That portion of the original comment in bold letter and underscored has yet to be addressed to compliance. They are the following: 1. As per Land Use Code section 3.6.1.4.A.1., a residential development utilizing the RCP option must be in conformance with the design policies and criteria of the General Plan and any of its components, including adopted area and neighborhood plans. This site is within the bounds of the Tumamoc Area Plan (TAP), Subarea 4. A criteria within Subarea 4, under Natural Features Policy 1.c, states; Major washes, including the Silvercroft Wash should be left in their natural state unless there is a threat to private property or personal safety. Wash buffer zones should be provided, and wash and drainage treatment should be consistent with the intent to maintain natural areas and conservation linkages. The wash buffer zone is defined in the TAP as; A setback area bordering a wash that is predominantly NUOS, the buffer adds additional protection to an area equivalent to one-half the width of the wash on either side of the wash, not less than 25 feet wide, as measured from the edge of the 100-year floodplain. The wash buffer zone is a no -development/no-encroachment area. The wash buffer zone is not a land use zone adopted by the Land Use Code. It is derived from Plan policy In addition, the Silvercroft Wash is an ERZ Wash, which is subject to the Watercourse Ordinance adopted on November 7, 2006. Therefore, please revise the tentative plat and the landscape plan to comply with the City of Tucson Watercourse Ordinance, resolution No. 20505, and the Floodplain, Wash and Environmental Resource Zone (ERZ) Standards. In addition, the tentative plat and landscape plan shall comply with the Tumamoc Area Plan Policy which requests a wash buffer zone as outlined above. Therefore, based the above mentioned information, revise tentative plat and landscape plan to identify those portions of the ERZ Wash, including protected riparian areas outside of the 100 year floodplain limits, as common areas/natural undisturbed open space, as may be approved by the Office of Conservation and Sustainable Development (OCSD). Staff at OCSD may be reached at 837-6932. 2. Tumamoc Area Plan, Design Guideline 8 states that, Wash buffer zones should be protected from the impact of pet and human activity by construction of fencing or walls. Access from individual lots to conservation areas is discouraged. Pedestrian access should be only from a common access point. Based the above policy, please revise tentative plat and/or landscape plan to show location of walls or fences that will create a barrier between the ERZ Wash and the adjacent residential lots (This comment is intended for wall/fences to separate the residential lots from the COMMON AREAS, See portion of comment #1 in bold letters). Pedestrian access is encouraged in natural areas of the site when recreational amenities are approved as part of natural area amenities. However in this case, the required Local Trail # 136 is proposed beyond the boundaries of the site and based on this new information staff does not support human/pet activity within the natural undisturbed open space of the ERZ wash. 3. Again, DUPD staff recommends that prior to resubmitting, for the applicant to contact the Office of Conservation and Sustainable Development (OCSD) at 837-6932 to discuss the revisions/requirements as outlined in this and the prior review, as it pertains to compliance with Watercourse and ERZ Wash Ordinance requirements. The Department of Urban Planning and Design cannot consider this project in compliance without OCSD staff approval. DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S07-033 Starr Pass Vistas Village II 12/21/07 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Starr Pass Vistas Book 58, Page 20 NEIGHBORHOOD PLAN: Tumamoc Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 12/17/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X) Resubmittal Required: (X) Tentative Plat () Development Plan (X) Landscape Plan () Other REVIEWER: msp 791-4505 DATE: 12/17/07 Department of Urban Planning and Design (DUPD) S07-033, Starr Pass Vistas Village II: Tentative Plat Review December 17, 2007 DUPD previous comments have not been adequately addressed and therefore the proposed tentative plat (resubmitted) is not in compliance with staff's first comments provided in April of 2007. The following staff comments still need to be addressed: 1. As per Land Use Code section 3.6.1.4.A.1., a residential development utilizing the RCP option must be in conformance with the design policies and criteria of the General Plan and any of its components, including adopted area and neighborhood plans. This site is within the bounds of the Tumamoc Area Plan (TAP), Subarea 4. A criteria within Subarea 4, under Natural Features Policy 1.c, states; Major washes, including the Silvercroft Wash should be left in their natural state unless there is a threat to private property or personal safety. Wash buffer zones should be provided, and wash and drainage treatment should be consistent with the intent to maintain natural areas and conservation linkages. The wash buffer zone is defined in the TAP as; A setback area bordering a wash that is predominantly NUOS, the buffer adds additional protection to an area equivalent to one-half the width of the wash on either side of the wash, not less than 25 feet wide, as measured from the edge of the 100-year floodplain. The wash buffer zone is a no -development/no-encroachment area. The wash buffer zone is not a land use zone adopted by the Land Use Code. It is derived from Plan policy In addition, the Silvercroft Wash is an ERZ Wash, which is subject to the Watercourse Ordinance adopted on November 7, 2006. Therefore, please revise the tentative plat and the landscape plan to comply with the City of Tucson Watercourse Ordinance, resolution No. 20505, and the Floodplain, Wash and Environmental Resource Zone (ERZ) Standards. In addition, the tentative plat and landscape plan shall comply with the Tumamoc Area Plan Policy which requests a wash buffer zone as outlined above. Therefore, based the above mentioned information, revise tentative plat and landscape plan to identify those portions of the ERZ Wash, including protected riparian areas outside of the 100 year floodplain limits, as common areas/natural undisturbed open space, as may be approved by the Office of Conservation and Sustainable Development (OCSD). Staff at OCSD may be reached at 837-6932. 2. As part of the DUPD approval, please provide copy of letter made reference to (Department of Parks and Recreation, dated 4/11/07), as it relates to Local Trail # 136 (identified in the Eastern Pima County Trail System Master Plan for Silvercroft Wash). 3. Tumamoc Area Plan, Design Guideline 8 states that, Wash buffer zones should be protected from the impact of pet and human activity by construction of fencing or walls. Access from individual lots to conservation areas is discouraged. Pedestrian access should be only from a common access point. Based the above policy, please revise tentative plat and/or landscape plan to show location of walls or fences that will create a barrier between the ERZ Wash and the adjacent residential lots. Pedestrian access is encouraged in natural areas of the site when recreational amenities are approved as part of natural area amenities. However in this case, the required Local Trail # 136 is proposed beyond the boundaries of the site and based on this new information staff does not support human/pet activity within the natural undisturbed open space of the ERZ wash. 4. Again, DUPD staff recommends that prior to resubmitting, for the applicant to contact the Office of Conservation and Sustainable Development at 837-6932 to discuss the revisions/requirements as outlined in this and the prior review, as it pertains to compliance with Watercourse and ERZ Wash Ordinance requirements. DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S07-033 Starr Pass Vistas Village II 04/09/07 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Starr Pass Vistas Book 58, Page 20 NEIGHBORHOOD PLAN: Tumamoc Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 4/2/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X) Resubmittal Required: (X) Tentative Plat () Development Plan (X) Landscape Plan () Other REVIEWER: msp 791-4505 DATE: 4/2/07 Department of Urban Planning and Design S07-033, Starr Pass Vistas Village II: Tentative Plat Review April 2, 2007 Staff offers the following comments: Prior to resubmitting, staff recommends the applicant contact Ann Audrey from the Office of Conservation and Sustainable Development to discuss the revisions/requirements outlined below as it pertains to compliance with Watercourse and ERZ Wash Ordinances. Ms. Audrey may be reached at (520) 791-4505. 1. As per Land Use Code section 3.6.1.4.A.1., a residential development utilizing the RCP option must be in conformance with the design policies and criteria of the General Plan and any of its components, including adopted area and neighborhood plans. This site is within the bounds of the Tumamoc Area Plan (TAP), Subarea 4. A criteria within Subarea 4, under Natural Features Policy 1.c, states; Major washes, including the Silvercroft Wash should be left in their natural state unless there is a threat to private property or personal safety. Wash buffer zones should be provided, and wash and drainage treatment should be consistent with the intent to maintain natural areas and conservation linkages. The wash buffer zone is defined in the TAP as; A setback area bordering a wash that is predominantly NUOS … the buffer adds additional protection to an area equivalent to one-half the width of the wash on either side of the wash, not less than 25 feet wide, as measured from the edge of the 100-year floodplain. The wash buffer zone is a no -development/no-encroachment area. The wash buffer zone is not a land use zone adopted by the Land Use Code. It is derived from Plan policy In addition, the Silvercroft Wash is an ERZ Wash, which is subject to the Watercourse Ordinance adopted on November 7, 2006. Therefore, please revise the tentative plat and the landscape plan to comply with the City of Tucson Watercourse Ordinance, resolution No. 20505, and the Floodplain, Wash and Environmental Resource Zone (ERZ) Standards (see attached copies). In addition, the tentative plat and landscape plan shall comply with the Tumamoc Area Plan Policy which requests a wash buffer zone as outlined above. As per the Watercourse Ordinance, those portions of ERZ Washes with protected riparian areas need to be public, or located within common area of the recorded plat. Please revise tentative plat and the landscape plan to show protected riparian areas as common areas, as NUOS. As proposed private lot areas extend into and through in what seems to be riparian protected areas. Prior to resubmittal, please address these type of issues with Ann Audrey from the Office of Conservation and Sustainable Development, at 791-4505. 2. One of the main features and benefit of an RCP design is to protect natural terran and vegetation through clustering lots and establishing natural undisturbed open space (NUOS) and usable open spaces, in addition to minimal grading through the site. Therefore, please address how grading will be minimized within each lot. Please show building pad delineation and the square footage of pad area for each lot. Although building pad square footage should be minimal to help preserve the natural terran and vegetation, the pad layout needs to take into account accessory uses associated with custom built homes, such as detached accessory buildings, outdoor activity areas, pools, privacy walls. Lot areas outside of the building pad to remain undisturbed and outside of human activity/space needs. 4. The Eastern Pima County Trail System Master Plan identifies at this site the Silvercroft Wash to include local trail # 136. Please contact Mr. Glenn Hicks at 791-4873, at the Department of Parks and Recreation to determine type and amenities required on local trail #136 along Silvercroft Wash. At the time of resubmittal, please provide documentation of agreement with the Department of Parks and Recreation. 5. Staff is unable to determine if lot #25 has a buildable area. One of the purposes of an RCP project is to protect natural wash and floodplain areas by clustering lots with buildable areas outside of these protected resources. Please revise tentative plat to show how the 100-year floodplain limits effects the entire lot. Currently, only part of the floodplain limits are shown on this lot. If lot #25 has no acceptable buildable area then it needs to be considered as protected 100-year floodplain area. 6. Lots # 1, 2, 3, 17, 18, and 24 have area which may be buildable, but only accessible by encroaching through protected 100year floodplain limits. Please address how the 100-year floodplain and natural wash areas will be protected if these lots are divided by natural washes. Prior to revisions/resubmittal, staff recommends the applicant contact Ann Audrey at 791-4505 to address these issues. 7. Tumamoc Area Plan, Design Guideline 8 states that, Wash buffer zones should be protected from the impact of pet and human activity by construction of fencing or walls. Access from individual lots to conservation areas is discouraged. Pedestrian access should be only from a common access point. Please revise tentative plat and landscape plan to provide common access points to access the Silvercroft Wash, local trail # 136 amenities, as determined by the Department of Parks and Recreation. |
| 05/28/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S07-033 Starr Pass Vistas Village II 05/21/08 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Starr Pass Vistas Book 58, Page 20 NEIGHBORHOOD PLAN: Tumamoc Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 03/31/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (*) Approved, See Comment Listed Below () No Additional Comments – Complies With Planning Comments Submitted on: (*) A resubmittal will not be required by DUPD if prior to TP approval, the following notes are added as general notes on the tentative plat. All floodplain areas shall be NUOS, except where DS 9-06 applies. Each new owner must sign a disclosure form stating they are aware of the restrictions on the NUOS. This requirement shall be noted on the tentative plat. Specifications for open space protection should appear in the CC&Rs (if necessary, it shall allow removal of buffelgrass from NUOS areas). A 25-foot buffer is required along major washes, including Silvercroft. Walls shall be setback 25 ft from the floodplain boundary. REVIEWER: msp 791-4505 DATE: 05/21/08 |
| 05/30/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 21, 2008 Mirela Hromatka Rick Engineering Company, Inc. 1745 East River Road, Suite 101 Tucson, Arizona 85718 Subject: S07-033 Starr Pass Vistas Village II Tentative Plat Dear Mirela: Your submittal of March 10, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Tentative Plat (DUPD, DSD) 2 Copies Revised Landscape Plan (DUPD, DSD) THE ONE YEAR REVIEW PERIOD FOR THIS TENTATIVE PLAT EXPIRED ON MARCH 4, 2007. PRIOR TO RESUBMITTAL OF THESE PLANS, A WRITTEN REQUEST FOR A REVIEW EXTENSION MUST BE SUBMITTED TO AND APPROVED BY THE CDRC OFFICE. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |
| 05/30/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES ***REVISED*** May 30, 2008 Mirela Hromatka Rick Engineering Company, Inc. 1745 East River Road, Suite 101 Tucson, Arizona 85718 Subject: S07-033 Star Pass Vista Villages II Tentative Plat Dear Mirela: The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off: 1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO 2 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 tp-approved |