Plan Review Detail
Review Status: Completed
Review Details: ASSURANCES
Plan Number - S07-033
Review Name: ASSURANCES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/14/2008 | PATRICIA KRAUSMAN | START | ASSURANCES RECEIVED | Completed | Another copy of assurances submitted 12/18/07 made and forwarded to Engineering/EE at her request. |
| 02/29/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Starr Pass Vistas Village 2 (S07-033) Final Plat and assurances Review REVIEWER: Elizabeth Eberbach LOCATION: T14S R13E Section 16 ACTIVITY NUMBER: S07-033 SUMMARY: The Final Plat (received to Engineering on 22FEB08), assurance documents, CC&R's for original plat, and title report were received and reviewed for Final Plat conformance. The Final Plat and assurances are not recommended for approval at this time until comments are addressed. FINAL PLAT COMMENTS: 1) City of Tucson Development Standards (DS) Section No. 2-03.7: Submittal of the final plat prior to complete approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat. Address all Tentative Plat conditions of approval prior to resubmittal of Final Plat. 2) Assure that the descriptions of the common areas of the Final Plat title block match the CC&R's descriptions of the subdivision common areas and the descriptions in the assurance paperwork. Please be aware that the City of Tucson's legal office may reject the assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block. 3) DS Sec.2-03.6.1.L: Address the following legend comments: a) Add EHS line for clarification in legend. b) Clarify on planview or legend the 25' wash buffer zone (ERZ) or 25' ERZ wash buffer zone. 4) DS Sec.2-03.6.2.E: Revise/update general note 8: "Prior to issuance of any building permit, a Flood Plain Use Permit is required for lots (as provided) as well as street improvement." 5) Add general note regarding individual grading permits for each lot. 6) DS Sec.2-03.6.4.I: Show any applicable minimum geotechnical basin setback in lots 9, 10, 41, and 42. 7) DS Sec.2-03.6.5.C.5: Address the following survey comments: a) DS Sec.2-03.6.5.C.3: Provide parcel boundary legal description as well as project boundary closure calculations with closing error. b) For planview sheets, add recorded, measured, or calculated labeling plat boundary data. c) DS Sec.2-03.6.4.F: For the surveyable EHS and 100-year floodprone limits, show more/additional frequent ties to intersecting lot lines. Check / clarify lots 17 and 24. Check data for clarity; it may be necessary to use crow's feet for some lengths. 8) DS Sec.2-03.6.5.B: Address the easement comments: a) Assure Title Report Schedule B items 4 and 5 are addressed on the plat. Any easements shall be shown with docket and page, or title report updated for any abandonments. b) Delineate and label a private drainage maintenance easement near lots 17 and 23 and any other lots, for the pipe culverts. 9) DS Sec.2-03.6.6.A: Only a copy of the original plat's CC&R's were submitted. Address the following CC&R comments: a) DS Sec.10-02.14.3.2: An original signed copy of the CC&R's will be required for Final Plat approval. For plat approval, the Covenants, Conditions, and Restrictions (CC&Rs) or Final Plats (cover sheet notes) shall have the following statements: i) that the owner or owners shall be solely responsible for operation, maintenance, and liability for drainage structures and detention basins; ii) that the owner or owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and detention/retention facilities at least once each year, and that these regular inspection reports will be on file with the owner for review by City staff, upon written request; iii) that City staff may periodically inspect the drainage and detention/retention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and iv) that the owner or owners agree to reimburse the City for any and all costs associated with maintaining the drainage and detention/retention facilities, should the City find the owner or owners deficient in their obligation to adequately operate and maintain their facilities. b) Address the following other CC&R's comments: i) Assure that the description of the project on the Final Plat title block match the CC&R's description of the subdivision on page one of the CC&R's. ii) Add case number S07-033 to first sheet of CC&R's. c) Add easement maintenance verbiage to CC&R's or a general note to the Final Plat cover sheet: All erosion protection and revegetation in all easements shall be the responsibility of the Homeowners Association. CC&R'sArticle IX or other section may need to be revised. 10) DS Sec.10-02.14.3.2, DS Sec.2.3.1.6.C: The CC&R's shall also provide the list of maintenance recommendations for the drainage areas (drainage channels, basins, culverts, and other drainage structures or improvements) as outlined in the project's Drainage Report or as provided by the project's engineer and accepted by the City of Tucson DSD engineer. ASSURANCES COMMENTS: 11) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Submit the following for the assurance package: a) Address the following third party trust subdivision assurances comments: i) Revise Final Plat Title Block to match subdivision description for "private streets". ii) Assure that all exhibits are attached; AGREEMENT TO CONSTRUCT is missing the Exhibit A. iii) Assure that each page of the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST has page numbering; iv) Assure the case number "S07-033" is each page of the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST; b) For this and future projects, please provide a 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council. Typically, these are similar to an enlarged location map on Final Plats. i) Provide the following for the resubmittal: (1) original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST with the assurable items list; (2) original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST; (3) copy of the original Trust Agreement; (4) copy of a sample Warranty Deed; (5) copy of the current Title Report. 12) DS Sec.2-03.6.3: The Tucson City Clerk, Kathleen S. Detrick, is retiring. Effective February 2, 2008, all correspondence for the City Clerk should be addressed to Roger W. Randolph per the City Clerk's Office. Mr. Randolph will serve as the City Clerk until such time as a City Clerk is appointed by Mayor and Council. Revise Approvals section verbiage on sheet 1 to state: "The undersigned, Roger W. Randolph, Clerk of the City of Tucson, Arizona, hereby certifies that this plat was approved by the Mayor and Council of the City of Tucson, Arizona, on this __ day of ________, 200__. Submit the revised Final Plat, revised CC&R's, copy of the title report, boundary closure info, an revised assurance package, and response letter. You may call to go over these comments, or if you have any questions, please call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |