Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S07-025
Parcel: Unknown

Address:
7710 S WILMOT RD

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S07-025
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2008 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator
FOR: A. C. Tsang Engineering
SUBJECT: Wilmot/I-10 Commercial Center Final Plat 1st submittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S07-025

SUMMARY: The Final Plat submittal was reviewed for code compliance and against the rezoning conditions. Development Services Department Engineering Division does not recommend approval of the Final Plat until the assurances and revised final plat comments are addressed.

FINAL PLAT COMMENTS:
1) City of Tucson Development Standards (DS) Section No. 2-03.7: Submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat. Assure that the final plat reflects approved tentative plat entities and layout.
2) DS Sec.2-03.7.1.D: Address the following rezoning comments:
a) Rezoning condition 32 requires a common area or PAAL adjacent to the basin; the adjacent easement shown should also be labeled as a basin access easement.
b) Provide copy of rezoning conditions in next submittal and assure any other final plat related rezoning conditions are addressed.
3) DS Sec.2-03.7.1.E: Provide a copy of the Declaration of Covenants, Conditions and Restrictions (CC&R's) for the current proposed project that addresses the following comments:
a) Provide exhibits as referenced in the CC&R's.
b) DS Sec.10-02.14.3.3: Provide a revised drainage report or CC&R's for this project that addresses the following:
i) Revise section 3.6 in the existing CC&R's or provide verbiage in the Drainage Report for describing requirements of the certified annual report for maintenance of the proposed basin, stormdrain systems, channels, and other drainage structures, using the drainage maintenance verbiage from DS Sec.10-02.14.3.3.
ii) CC&R's shall provide the list of maintenance recommendations for the drainage areas as outlined in the Drainage Report or as provided by the engineer and accepted by the City of Tucson DSD Engineer. Assure that the Drainage Report or CC&R's are revised to include a maintenance checklist as provided in the Drainage Report from the approved Tentative Plat. The CC&R's or final plat notes shall incorporate the various drainage related conditions of rezoning or other special situations requiring permanent administration by an owners' association.
iii) Provide easement maintenance verbiage in the CC&R's or on Final Plat note, that all erosion protection, drainage improvements, and revegetation in all easements shall be the responsibility of the Homeowners Association, per recent City Attorney directive.
c) Consider providing a table of contents for the CC&R's.
d) Provide page numbering for every and all pages of a revised CC&R's including any table of contents and appendix.
e) Add Subdivision case number S07-025 to first sheet of revised CC&R's.
f) At Final Plat approval, a copy of the final Drainage Report and/or a signed original copy of the revised CC&R's will be required to be submitted to CDRC Office.
4) DS Sec.2-03.6.4.C: Basin shall be provided within a common area. Label the common area with a letter designation. Enclose with a solid line around the common area and provide square footage of area.
5) DS Sec.2-03.9.3.B: Provide seal on each sheet of the plat.
6) DS Sec.2-03.6.3 For Final Plat approval, all the signatures for each dedication and certification will be required. All signatures must be in permanent, black, india ink and be accompanied by a notary signature and seal.
7) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. In response letter, state type of assurance proposed for the project. Submit the following for the assurance package:
a) If a third party trust is proposed for the subdivision assurances, provide:
i) original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST with the assurable items list;
ii) original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST;
iii) assure that all exhibits are attached, and the case number "S07-025" is at the top of the first page of the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST;
iv) copy of the original Trust Agreement;
v) copy of a sample Warranty Deed;
vi) copy of the current Title Report.
vii) The assurance descriptions shall match the title block description on the first sheet of the Final Plat. Please be aware that the legal office may reject assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block.
b) For basins located within a common area, revise title block to reflect the basin in common area description.
c) For this and future projects, please provide a 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council. Typically, these are similar to an enlarged location map on Final Plats.
8) DS Sec.2-03.6: Address the following easement comments:
a) If easements are shown to cross proposed lot structure foot print locations, or proposed layout causes conflicts with the status of the easement, the easements may need to be physically abandoned and shall have a docket and page indicating that they are extinguished prior to approval of the Final Plat.
b) Assure all easements as listed in the Title Report and other documents are clearly drawn, labeled with Book/page or Docket/page, and/or listed as a blanket easement on the Final Plat. Label each street, alley, easement (type), and drainageway with the appropriate dedication notation. Specifically address the following:
i) Include/address schedule B items 5 and 7.
ii) Show the correct TEP easement recording information.
c) DS Sec.2-03.6.4.K: Show offsite construction easements required for construction of any improvements including drainage outlets.
9) DS Sec.2-03.6.5: Provide accurate dimensions, bearings, or deflection angles and radii, arcs, and central angles of all curves and lines. Address the following boundary data / survey comments:
a) Each utility easement shall have surveyable information provided; label additional dimensions, bearings and distances, and/or curve data for the easements located within each of the lots.
b) Verify bearing south of east quarter corner section monument and SE corner of section 24.
c) Add crow's feet to distance "519.27".
d) Add delineation from south end of "519.27" to southeast corner of property.
e) Check/clarify commercial entrance radii.
f) DS Sec.2-03.6.5.C.1.a: Label on planview "Basis of Bearings"
g) DS Sec.2-03.6.5.C.3: Provide closure sheet for project boundary.
h) On sheet 2, label / indicate for the distance and bearing between all monuments used as measured (M) or calculated (C) or recorded (R).
i) DS Sec.2-03.6.5.C.4.a: Fully describe and show all markings on found monuments.
j) DS Sec.2-03.6.4.I: The basin 100-year ponding limits must be drawn in a surveyable, retraceable manner within the common area.
k) DS Sec.2-03.6.3.A: Explain on the plat why 2 survey seals are provided.
10) DS Sec.2-03.6.1.D.2: Check location map to see that all entities are identified within the square mile area, such as all subdivisions, major streets, major watercourses, and railroads. Reference recorded subdivision plats by book and page numbers. Add Desert Stone, La Estancia, Old Rodeo ERZ Wash, and Wilmot Road.
11) DS Sec.2-03.6.1.L: Address the following legend comments:
a) Provide in the legend linetypes used on the drawing, including centerline and easements.
b) Clarify monuments to be set or found.
12) DS Sec.2-03.6.2.A: Address the following General Note comments:
a) Add the following as Final Plat General Notes:
i) Include verbiage: "This plat is subject to the conditions of rezoning case number C9-01-05, unless superseded by a subsequent rezoning ordinance."
ii) DS Sec.2-03.6.2.I: "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public."
iii) DS Sec.2-03.6.2.E: If subject to floodplain or EHS requirements, add the following note: "Prior to issuance of any building permit, a Flood Plain Use Permit is required for Lots 1 and 6."
b) Revise General Note 6 to state "…approval of the City of Tucson." "
13) DS Sec.2-03.6.3: Update year references on plat to 2008.
14) DS Sec.2-03.6.3.B.2.c: Under Dedication section on sheet 1 check verbiage in fourth paragraph: "Drainageways and common areas, as shown hereon, are reserved for the private use and convenience of all owners of property within this subdivision and are granted as easements to the Public and all utility companies for the purposes of access, installation, and maintenance of utilities, drainage, and public sewers. Title to the land of all private streets, drainageways, and common areas shall be vested in an association of individual lot owners as established by Covenants, Conditions, and Restrictions recorded in Docket ____ at Pages ____ through ____ in the office of the Pima County Recorder. The association will accept responsibility for control, maintenance, and liability for the private streets, drainageways, private sewers, and common areas within this subdivision."
15) DS Sec.2-03.6.4.E: Show required dimensioned setbacks, such as erosion hazard, drainage, etc.
16) Submit the revised Final Plat addressing all of the comments, the drainage report, the revised CC&R's, additional notarized offsite improvement authorizations, assurance package, copy of rezoning conditions, and response letter thoroughly explaining each comment.

If you have questions or would like to set up a meeting, call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
01/08/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 8, 2008

A.C. Tsang Engineering Group, Inc.
Antony C. Tsang
4626 East Fort Lowell, Suite S
Tucson, Arizona 85712

Subject: S07-025 Wilmot/I-10 Commercial Center Final Plat

Dear Tony:

Your submittal of November 7, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Final Plat (Wastewater, Addressing, Zoning, TEP, Engineering, DSD)

2 Copies Drainage Report (Engineering, DSD)

2 Copies Notarized offsite improvement authorizations (Engineering, DSD)

3 Copies CC&R's (Zoning, Engineering, DSD)

2 Copies Rezoning Conditions (Engineering, DSD)

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 325-0979
fpresubmittal
11/06/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/07/2007 CDRC1 PIMA COUNTY WASTEWATER Denied November 7, 2007

To: Antony Tsang
Tsang Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Wilmot / I10 Commercial Center, Blocks 1-6
Final Plat - 1st Submittal
S07-025

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. Sheet 1: In the Dedication Block, third paragraph, first line after the word PUBLIC add the words ,PIMA COUNTY.

2. Sheet 1: Include the beneficiary of Trust # 8061 and 8062T.

3. The Final Plat cannot be approved until the Tentative Plat has been approved.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the . The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.
The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.
If you have any questions regarding the above-mentioned comments, please contact me.
11/14/2007 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
11/23/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S07-025 WILMOT/I-10 COMMERCIAL CENTER/FINAL PLAT
DATE: 11/20/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE: Approved with the following condition:

1.) Label with a "Star" symbol, access point for all lots on mylar.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***

es
11/27/2007 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S07-025
Wilmot/I-10 Commercial Center
Final Plat

TRANSMITTAL DATE: November 25, 2007

DUE DATE: December 6, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. As of this final plat review date the tentative plat has not been approved therefore the one year date of the final plat approval is based on the date of submittal of the final plat documents, November 6, 2008. Once the tentative plat has been approved the approval date of the final plat will be on one year from the tentative plat approval date. This date will be provided on a future review of the final plat.

2. The property is subject to conditions of rezoning, add the following note: "This plat is subject to the conditions of rezoning case number C9-01-05, unless superseded by a subsequent rezoning ordinance."
DS 2-03.6.2.D

3. Please correct the first paragraph of the dedication section changing "hereby warrant that we are all…" to "hereby warrant that we are the only parties…", as describe in DS 2-03.6.3.B.1.

4. It is advised to remove date using 2007 replacing them with 20___., in case final is not approved until after the new year.

5. Please correct the spelling of the Pima County Recorder's name to F. Ann Rodriquez in the recording paragraph.

6. Please remove the ten (10) foot landscape buffer from the final plat. This is required only on the tentative plat.

7. The title page of the CC&Rs is to include the name of the final plat including the number of blocks. Please revise.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

KAA S:\zoning review\karol\planning\cdrc\finalplat\S07-025fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
11/29/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: WILMOT/I-10 COMMERCIAL CENTER

S07-025



Tucson Electric Power Company (TEP) has reviewed the final plat
submitted November 7, 2007. TEP is unable to approve the plat at this
time.



There are two TEP Right of Way easements within the boundaries of this
development. In order for TEP to approve the plat the easements must be
shown with the correct recording information: (Docket-12769 Page-1617)
& (Docket-12444 Page-1040).



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
11/29/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: WILMOT/I-10 COMMERCIAL CENTER

S07-025



Tucson Electric Power Company (TEP) has reviewed the final plat
submitted December 18 2007. TEP is unable to approve the plat at this
time.



There are two TEP Right of Way easements within the boundaries of this
development. In order for TEP to approve the plat the easements must be
shown accurately with the correct recording information: (Docket-12769
Page-1617) & (Docket-12444 Page-1040). See attached.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
12/05/2007 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: December 3, 2007


RE: Assessor’s Review and Comments Regarding Final Plat
S07-0256 WILMOT/I-10 COMMERCIAL CENTER T151424


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS:

THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390


ROSANNA WERNER
12/06/2007 FRODRIG2 COT NON-DSD REAL ESTATE Approved >>> Andy Steuart 12/06/2007 8:39 AM >>>
S07-025 Wilmot/I-10 Commercial Center: Plat Review
-No comment.