Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S07-025
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/02/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | October 1, 2007 To: Antony Tsang Tsang Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: Wilmot / I10 Commercial Center, Blocks 1-6 Tent. Plat – 3rd Submittal S07-025 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 2: Clearly identify the sewer line and manholes on property to be abandoned per this plan. Also the manholes and sewer line along Wilmot to be abandoned per G-2005-077 should be clearly identified on this plan. Sheet 2: The existing manholes per plans G-93-085 do not appear to all be correct. MH 50-30 as shown on plan should be MH 50-29 per Map Guide. Please verify . Sheet 2: Label all of the BCS connections as Private BCS and show the pipe size and minimum slope of 2%. Sheet 2: Public manholes #1 and #3 are not called out and the rim and invert elevations are missing. Sheet 2: A joint sewer service agreement will be required for Lots 3, 4 and 5 which are sharing a 6” private BCS. Contact Mrs. Ilene Deckard of PCWMD @(520)740-6544. Sheet 2: The rim and invert elevations are missing for all of the existing public manholes shown on plan. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the tentative or preliminary plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the fourth(4th) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above-mentioned comments, please contact me. |
| 10/11/2007 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#178117 October 10, 2007 Dear : Antony Tsang: SUBJECT: WILMOT / I-10 COMMERCIAL CENTER - Resubmittal S07-025 Tucson Electric Power Company has reviewed and disapproved the development plan submitted October 3, 2007. The underground electric line serving the sign at the north east corner of the lot must be identified on the plans for approval A facilities map is attached for reference. Conflicts can not be determined until facilities are properly indicated on the plan. Any relocation costs will be billable to the customer. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Please call the area Designer Steve Garcia at (520) 917-8739, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures Cc S. Garcia, Tucson Electric Power P. Gehlen, City of Tucson (E-Mail) |
| 10/11/2007 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#178117 November 5, 2007 Dear : Antony Tsang: SUBJECT: WILMOT / I-10 COMMERCIAL CENTER - Resubmittal S07-025 Tucson Electric Power Company has reviewed and approved the development plan submitted October 3, 2007 It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. All relocation costs are billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Please call the area Designer Steve Garcia at (520) 917-8739, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures cc: City of Tucson, (Email only) S. Garcia, Tucson Electric Power |
| 10/23/2007 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Denied | ADOT has one comment on this project; - the 1" 'NO Access Easement' is not the same as Access Control line along the frontage road, please call it out on the plan and identify it graphically If you have any comments or questions on this review I can be contacted at 388-4226. Thank you. TM. |
| 11/21/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | TO: Patricia Gehlen; CDRC Coordinator FOR: A. C. Tsang Engineering SUBJECT: Wilmot/I-10 Commercial Center Tentative Plat Re-submittal Engineering Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: S07-025 SUMMARY: The Tentative Plat submittal was reviewed for code compliance and against the rezoning conditions. Development Services Department Engineering Division recommends conditional approval of the Tentative Plat. The Drainage Report was reviewed for Tentative Plat purposes only. TENTATIVE PLAT CONDITIONS OF APPROVAL: 1) DS Sec.2-03.2.4.L: Address the following drainage comments: a) The Q100 outlets for the basin shall be labeled on the plat. b) Clarify 100-yr floodplain limits on exhibits. Blackhawk Ranch Drainage Report was not approved by the City of Tucson. Provide floodplain analysis or reference to an approved project. 2) DS Sec.2-03.3.1.J: Regarding compliance of rezoning conditions: a) Grading Plan shall show how Rezoning condition 30 is met by indicating required sediment trap system. b) DS Sec.3-01.5.1.B.1: Show SVT's on planview for south entrance at Wilmot Road. If you have questions or would like to set up a meeting, call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 11/26/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 26, 2007 A.C. Tsang Engineering Group, Inc. Antony C. Tsang 4626 East Fort Lowell, Suite S Tucson, Arizona 85712 Subject: S07-025 Wilmot/I-10 Commercial Center Tentative Plat Dear Tony: Your submittal of September 25, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 5 Copies Revised Tentative Plat (Engineering, TEP, ADOT, Wastewater, DSD) 2 Copies Revised Landscape Plan (Engineering, DSD) BASED ON COMMENTS FROM TEP, A REVISED COPY OF THE TENTATIVE PLAT WAS SUBMITTED TO THEM BUT DID NOT COME THROUGH THE CDRC OFFICE. TO ENSURE THAT TEP COMMENTS HAVE BEEN ADDRESSED, ANOTHER COPY WILL BE REVIEWED BY TEP. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 325-0979 |