Plan Number: S06-270
Parcel: Unknown

Address:
6702 S WILMOT RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-270
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/25/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-270
Littletown/Wilmot Industrial
Tentative Plat

TRANSMITTAL DATE: September 21, 2007

DUE DATE: October 12, 2007

COMMENTS:

The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.




If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-270tp2.doc
10/03/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond DATE: October 3, 2007
TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Littletown and Wilmot Industrial Park Tentative Plat Engineering 3rd Resubmittal Review
REVIEWER: Elizabeth Eberbach
LOCATION: T15S R14E Section 13, Ward 5, East Impact Fee area, FIRM panel 2265K
ACTIVITY NUMBER: S06-270

SUMMARY: The revised Tentative Plat sheets, landscape documents, and response letter were received by Engineering for review. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering recommends conditional approval of the Tentative Plat. Address the following conditions for/prior to mylar submittal of the Tentative Plat.

TENTATIVE PLAT CONDITIONS OF APPROVAL:
1) Tucson Code Chapter 26 Article I Division 1 Section 26-5.2(4): Submit a revised drainage report. Regarding the 100-year regulatory floodplain riparian areas, state in drainage report that Landscaping does not recognize any riparian habitat for this project and therefore the project does not need to show compliance with DS Sec.2-13.
2) Clarify basin access ramps (15-ft wide, 15% max slope) on plan view.
3) General Tentative Plat comments:
a) DS Sec.2-03.2.4.M & DS Sec.3-05.5.3: For sight visibility triangle data, remove or clarify distance between SVT's; 16-ft width does not necessarily apply.
b) Basins will need to be more clearly delineated on the Final Plat for common area definition and clarification.
c) Add "detention" to general note 23, details 3/5, 4/5, and any other "retention basin" call out.
d) Basins still need to be shown to reflect minimum setback from property line. Additional area for sufficient space shall be provided for the erosion protection spillway for north basin.
e) On details on sheet 5 address the following:
i) Show minimum setback. Response letter stated that the setback was shown however only a note was added near the details stating that the setback was shown on planview but the layout appears to have the north basin on the property line without setback. Planview and details should show minimum setback.
ii) Clarify erosion protection for basin slopes to include filter fabric with the proposed rip rap.
f) Regarding the DSMR, clarify section details 1 and 2 on sheet 5 to state that the asphalt shoulder is also a sidewalk area.

Submit revised Tentative Plat, revised Drainage Report, and response letter. Please call me for clarifications at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
10/12/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 12, 2007

Jerry Zillman
The WLB Group
4444 Broadway Blvd.
Tucson, Arizona 85711

Subject: S06-270 Littletown/Wilmot Industrial Tentative Plat

Dear Jerry:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off:

1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO.
2 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3.

TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html.

Should you have any questions, please call me at 837-4919.

Sincerely,

Patricia Gehlen
CDRC Manager
All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 881-7492
10/12/2007 FRODRIG2 COT NON-DSD REAL ESTATE Approved >>> Andy Steuart 10/12/2007 11:21 AM >>>
S06-270 Littletown/Wilmot Industrial: Resubmittal - CDRC - Tentative Plat Review
Per 10/10/07 discussion w/ Bob Patrick, WLB Group, concerning annotation "Self-Extinguishing Temporary Turnaround Easement to be Abandoned when Littletown Improvements are Constructed" and Lots 18 & 19. The dispensation of the easement will be handled when ownershio of the two parcels transfer.

Real Estate Division has no objection to this tentative plat.