Plan Number: S06-270
Parcel: Unknown

Address:
6702 S WILMOT RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-270
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/16/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/27/2007 CDRC1 PIMA COUNTY WASTEWATER Approved July 26, 2007

To: Jerry Zillman
WLB Group

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Littletown and Wilmot Industrial Park, Lots 1-24 & Common Areas "A", "B" & "C"
Tent. Plat - 3rd Submittal
S06-270

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative or preliminary plat as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above-mentioned comments, please contact me.
07/31/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-270
Littletown/Wilmot Industrial
Tentative Plat

TRANSMITTAL DATE: July 27, 2007

DUE DATE: August 13, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

If the DSMR was not approved then the previous comment stands.

Sidewalks are required as part of new development of all properties. All new subdivisions and applications for building permits shall provide five (5) foot wide sidewalks along the entire length of street frontage, whether public or private, of the property in question. A two (2) foot shy area is required between the wedge curb and sidewalk area. Based on the proposed ADT the street cross section is to be designed as provided in 3-01.10 Figure 5. Please provide revise details for 1/5 and 2/5 on sheet 5 of 5.
DS 3-01.3.3.A & DS 3-01.10 Figure 5


If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-270tpr1.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat additional requested documents.
08/02/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
08/06/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-270 LITTLETOWN/WILMOT INDUSTRIAL/REVISED TENTATIVE PLAT
DATE: August 6, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.





***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***



jg
08/10/2007 FRODRIG2 COT NON-DSD REAL ESTATE Denied Andy Steuart
S06--270 Littletown/Wilmot Industrial: Resubmittal - CDRC - Tentative Plat Review - Request the following:
-Because of private streets, annotate a solid property line where Street A intersects w/ Wilmot Rd.
-Concerning Street B, a "self extinguishing easement" is questionable. Should this private street ever be conveyed for public R/W purposes, street improvements would be on private property and cause a potential liability.
-Request private Street A and B be designated as a Common Area.
08/13/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
08/23/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

August 23, 2007

Jerry Zillman
The WLB Group
4444 Broadway Blvd.
Tucson, Arizona 85711

Subject: S06-270 Littletown/Wilmot Industrial Tentative Plat

Dear Jerry:

Your submittal of July 17, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Tentative Plat (Zoning, Real Estate, Engineering, DSD)

3 Copies Revised Landscape Plan (Zoning, Engineering, DSD)

2 Copies Drainage Report (Engineering, DSD)


Should you have any questions, please call me at 837-4919



Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 881-7492
08/23/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Littletown and Wilmot Industrial Park Tentative Plat Engineering 2nd Resubmittal Review
REVIEWER: Elizabeth Eberbach
LOCATION: T15S R14E Section 13, Ward 5, East Impact Fee area, FIRM panel 2265K
ACTIVITY NUMBER: S06-270

SUMMARY: The revised Tentative Plat sheets, revised Drainage Report, revised geotechnical investigation report, landscape documents, annexation agreement document, and response letter were received by Engineering for review. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering does not recommend approval of the Tentative Plat at this time. Address the following comments.

DRAINAGE COMMENTS:
1) Tucson Code Chapter 26 Article I Division 1 Section 26-5.2(4): Regarding the 100-year regulatory floodplain riparian areas, if Landscaping does not recognize any riparian habitat for this project, then the project does not need to show compliance with DS Sec.2-13.
2) DS Sec. 2-03.2.4.L, Tucson Code Sec.26-5.2(5): Lot buildable area shall be shown on the floodplain affected lots. Show maximum encroachment line so as not to cause adverse impact. Show areas on each lot, that have floodplain limits, that shall not be developed with fill on planview of tentative plat. Development in floodway fringe area may not increase the base flood elevation more than 1/10th of a foot for any offsite property. Discuss results of analyses and impact and any raise due to future base flood elevation in the drainage report. Otherwise, revise note 14 or add a general note to the plat stating that the following lots ( ) may be restricted in buildable area due to floodplain encroachment, or similar verbiage.

TENTATIVE PLAT COMMENTS:
3) DS Sec.2-03.2.3.A: A local benchmark with elevation will be required for Final Plat and Grading Plan review.
4) DS Sec.2-03.2.4.J: Regarding the MCI / Fiber Optic cable line, the minimal restricted cut or fill as directed by Utility company shall be complied with and shown on the grading plan. Also, indicate general location of this line on details 5 and 6 on sheet 5.
5) Address the following drainage related comments:
a) DS Sec.2-03.2.4.L.2: Add lot 6 to general note 46 regarding required Floodplain Use Permits.
b) DS Sec.2-03.2.4.L.2: Per exhibit 3 assure all floodplain - affected lots have the minimum FFE's labeled on Tentative Plat planview.
c) Clarify general note 49 regarding the minimum FFE's for each of the proposed lots, add unless otherwise labeled or similar verbiage.
6) DS Sec.2-03.2.4.M: On sheet 2, add 3-ft minimum setback dimension around basin for lots 17 and 18 per geotechnical recommendations.
7) Address the remaining street comments:
a) DS Sec.2-03.2.4.M & DS Sec.3-05.5.3: Revise sight visibility triangle lengths on planview sheets to reflect data on sheet 5 for Collector/Arterial line of sight distances. SVT lines are not clearly shown - may want to use other linetype thickness or other way to clarify these delineations.
8) General Tentative Plat comments:
a) Basins must be defined within common areas (with square footage) or clarified for maintenance responsibility.
b) Basins shall be pulled back away from property line per 2-ft minimum slope setback requirements. Additional area for sufficient space shall be provided for the erosion protection spillway for north basin.
c) At grading plan review stage, a minimum of 1% basin bottom gradient will be required.
d) On details 3 and 4 on sheet 5 address the following:
i) Show minimum setback.
ii) Clarify required erosion protection for fill slopes for basins to address unattenuated flow conditions.
e) Provide copy of DSMR in resubmittal. It will need to be clarified whether DSMR applies to frontage along Wilmot and Littletown Road. Otherwise show MS&R sidewalk along both frontage roads on cross sections and planviews.


The next submittal should address all the above items. Submit revised Tentative Plat, revised Drainage Report, and response letter. If you have any questions, please call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services