Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S06-260
Parcel: Unknown

Address:
1615 E ALLEN RD

Review Status: Completed

Review Details: RESUBMITTAL- RECORD OF SURVEY

Plan Number - S06-260
Review Name: RESUBMITTAL- RECORD OF SURVEY
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/14/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/15/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Denied March 15, 2007
ACTIVITY NUMBER: S06-260
PROJECT NAME: Allen Road Estates
PROJECT ADDRESS: 1615 E Allen Rd
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the Record of Survey; therefore a revised Record of Survey is required for resubmittal.

The following items must be revised or added to the Record of Survey.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. A separate schematic drawing should be used as a schematic site plan to illustrate and dimension the location(s) of the proposed and existing adjacent driveways. The Record of Survey should only contain survey information regarding the lot and public Right of Way survey information. Feel free to contact me with questions and/or for clarification.

3. The maximum curb cut width for 2 adjoining lots is 20 per the Tucson City Code Chapter 25 and Access Management Guidelines. The drawing illustrates an opening of 38 feet.

4. One curb cut can only serve 2 adjoining lots, and a street is required for an opening serving 3 or more lots. The drawing illustrates that the 38-foot opening is serving 3 lots; please revise and provide a separate curb cut for the excluded parcel.

As stated above if you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
03/27/2007 SUZANNE BOHNET ENGINEERING REVIEW Approved DATE: March 27, 2007

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Suzanne Bohnet, CFM
Engineering Division

SUBJECT: S06-260 Allen Road Estates: Record of Survey (First Review)
T13S, R14E, Section 30

NO RESUBMITTAL REQUIRED.

The Engineering Division has reviewed the Record of Survey and recommends approval at this time.

Suzanne Bohnet, CFM
Engineering Associate
04/09/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S06-260
Allen Road Estates
Record of Survey

TRANSMITTAL: 04/09/07

DUE DATE: 04/11/07

COMMENTS:


1. DS 2-03.11.12.B Show no-vehicular use easements where applicable. A one (1) foot no-vehicular use easement will be required on parcels "C" and "D" along the east, west and north property lines of the excluded parcel. Recordation information (docket and page) for the no-vehicular use easement must be included on the plan prior to approval.

The above information has been provided on the reference sheet. Provide on the sheet that will be used for the recording purposes.

2. The reference sheet is the only sheet that has been resubmitted. Provide the sheet that will be used for recording purposes with the next submittal.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.

TLS C:\planning\cdrc\record of survey\S06-260ros.doc
04/11/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-260 ALLEN ROAD ESTATES/REVISED RECORD OF SURVEY
DATE: April 10, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:



The legal description information on Title Block is not complete. Please correct.













jg
04/11/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-260 ALLEN ROAD ESTATES/REVISED RECORD OF SURVEY
DATE: April 12, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.
















jg
04/12/2007 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-260 Allen Road Estates: Resubmittal - Record of Survey - In/Egress & Utility Easements (Dkt./Pg. 12913/1221, 12913/1225) validity are questionable because the Grantor and Grantee are the same person. It is understood the easements are intended to convey access to follow-on Grantees, however what is in question is the sequence of conveyance and what rights are held & given up, which in the worst case could cause conflict.
04/13/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

April 13, 2007

Neil Snyder
Architique Homes
2561-2 East Fort Lowell Road
Tucson, Arizona 85716-1540

Subject: S06-260 Allen Road Estates Record of Survey

Dear Neil:

Your submittal of March 14, 2007, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Record of Survey (Traffic, Real Estate, Zoning, DSD),









Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 795-2686
04/13/2007 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review