Plan Number: S06-257
Parcel: Unknown

Address:
1717 E GLENN ST

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S06-257
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2007 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Hidden Glenn Condos
S06-257
Final Plat (1st Review)

TRANSMITTAL DATE: December 29, 2006

DUE DATE: January 08, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

FINAL PLAT:
1. An applicant has one (1) year from the date of application to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before December 06, 2007.

2. Provide the last approved site plan which shows the covered parking approved

3. D.S. 2-03.6.1.D Identify the subdivisions within the one (1) square mile. Reference recorded subdivision plats by book and page number.

4. D.S. 2-03.6.1.H Within the title block revise "C.E. "B" PRIVATE RECREATION AND LANDSCAPE AREAS" to read "C.E. "B" LAUNDRY BUILDING, RECREATION AND LANDSCAPE AREAS"

5. D.S. 2-03.6.1.H Add to the title block. "A RE-SUBDIVISION OF HEDRICK ACREAGE TRACT NO, Map & Plats: Book 4 @ Page 1".

6. D.S. 2-03.6.1.K Place the S06-257 subdivision case number in the lower right corner of the plat next to the title block.

7. D.S. 2-03.6.1.K Place the C9-77-33 zoning case number in the lower right corner of the plat next to the title block on all sheets.

8. D.S. 2-03.6.2.D C10-00-67 is a Board of Adjustment number not a Rezoning number, see comment 8.

9. D.S. 2-03.6.3 The second signature line should read "CITY OF TUCSON ENGINEER" not "CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT ENGINEERING ADMINISTRATOR".

10. Provide Square Footage & Volume Matrix tables.

11. Please provide written documentation on how LUC section 4.1.9 will be met for this proposed condominium conversion project.

PROTECTIVE COVENANTS:
1. Provide a table of contents for the convenient.


If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C\planning\cdrc\finaplat\S06-257fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
01/05/2007 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor


115 N. Church Ave.


Tucson, Arizona 85701



BILL STAPLES

ASSESSOR










TO: CDRC Office

Subdivision Review

City of Tucson (FAX# 791-5559)



FROM: Gary Ault, Mapping Supervisor

Pima County Assessor's Office

Mapping Department



DATE: January 5, 2007





RE: Assessor's Review and Comments Regarding Final Plat

S06-257 HIDDEN GLENN CONDOS T131431





* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *



X Plat meets Assessor's Office requirements.

_______ Plat does not meet Assessor's Office requirements.





COMMENTS:

THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL
ROSANNA WERNER AT 740-4390



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS
TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN
THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING
THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK
YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.













ROSANNA WERNER
01/09/2007 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
01/09/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond January 8, 2007

TO: Doug Schneider, P.E.
Rick Engineering Company.

THRU: Patricia Gehlen, CDRC Manager
City of Tucson, Development Services Department

FROM: Chandubhai C. Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Hidden Glenn Condominiums, Units 1 Thru 19 and C. E. “A” and C.E. “B” and L.C.E. 1 Thru 19
Final Plat – 1st Submittal, S06-257


The drawings for the proposed Final Plat for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

ALL SHEETS. Add the project number, S06-257, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

SHEET 1. Add a General Note that reads:

This is an apartment to condominium conversion project. The onsite sewers, except the public sewers within the public sewer easements, are existing and private. No new sewer lines are proposed.

3. SHEET 1. LOCATION MAP. It appears that the township should be T 13 S rather than T 15 S as shown. Please verify and make correction as necessary.

SUBJECT TO THE ABOVE, The Pima County Department of Environmental Quality and the Wastewater Management Department hereby CONDITIONALLY approve the above referenced submittal of the Final Plat as received by us on December 7, 2006. The revisions may be shown on the mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution.

If you have any questions regarding the above comments, please do not hesitate to contact me.

Sincerely,



Chandubhai C. Patel, P.E.
Telephone: 520-740-6563

Copy: Project File
01/10/2007 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-257 Hidden Glenn Condos: Final Plat Review - Request 2' along E. Glenn St. be dedicated for R/W. MS&R shows a 64' width and 32' from centerline of Glenn St. Plat shows 30' from centerline to existing property line.
01/10/2007 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-257 HIDDEN GLENN CONDOS/FINAL PLAT
DATE: 1/05/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Shade in the project on the Location Map.

Change T15S to T13S under Location Map.

Include all resubdivsion information on all Title Blocks.

Correct Sections on Location Map.

Add Road to Ft. Lowell on Location Map.

Correct scale on pg. 2.

Address condominiums per attachment.

es
01/16/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator DATE: January 16, 2007

SUBJECT: Engineering review of the Hidden Glenn Final Plat. The activity number is S06-257.

SUMMARY: The Final Plat and CC&Rs were received by Engineering on December 7th, 2006. Engineering has reviewed the received items and does not recommend approval of the Final Plat or the CC&Rs.

RESUBMITTAL REQUIRED: FINAL PLAT, CC&Rs, TITLE REPORT

SUBMITTAL REQUIRED: BOUNDARY CLOSURE CALCS


The next submittal must address the following items:

FINAL PLAT COMMENTS

1. Provide the correct number for the township located under the project location map. DS 2-03.61.D.3.

2. Provide all symbols used on the plat in the legend. DS 2-03.6.1.L.

3. Provide the subdivision case number in the lower right hand corner of each sheet. DS 2-03.6.1.K.

4. Please refer the beneficiary block to verify if the correct verbiage has been used. After a conversation with Doug Schineider, there should be language regarding, "Consent to Subdivide." DS 2-03.6.3.C.

5. Common Elements with separate restrictions must be clearly delineated with a solid line. Common Element "A" is difficult to determine on the plat view. It is clear Common Element "A" represents the PAAL for this project, however there are a couple of areas that are not clear. It is unclear if the space in front of LCE 19A - 20B represents Common Element "A" or "B". Provide a darker line weight to delineate Common Element "A" more clearly. DS 2-03.6.4.C.

6. Common Element "B" located on the north side of the property, between unit 8 and 9 has a line where it is not clear if this is a dimension to designate a common element or representing a site amenity. Please clarify and provide a darker line weight to differentiate between Common Element "A" and "B." DS 2-03.6.4.C.

7. Include the "laundry building" in the description of Common Element "B" or provide a separate common element for the laundry building. DS 2-03.6.4.C.

8. Show no-vehicular access easements if applicable to this project. DS 2-03.6.4.H.

9. Corner tie information is to be provided on the plat. At least one corner of the subdivision must be tied by course and distance to a section corner or a quarter section corner. The plat must include a description of that corner marker and an indication of how the bearings were determined. Provide the corner tie recordation information on the plat. DS 2-03.6.5.A.

10. Provide dimensions and bearings for the 10' public utility easement. DS 2-03.6.5.B.

11. The northwest corner of the property is not described. If there is no monumentation in the northwest corner provide monumentation. Indicate as found or set. Revise appropriately. DS 2-03.6.5.C.4.a.

12. Clearly indicate on the plat which line is the centerline and monument line for Glenn Street. DS 2-03.6.5.

13. Describe all deflection points on the monument and centerline for Glenn Street. DS 2-03.6.5.

14. Clarify the two bends in the centerline and monument line of Glenn Street. DS 2-03.6.5.

15. Fully describe the found (including brass cap survey) monumentation. It is not necessary to fully describe the "X" markout on the sewermanhole monumentation, since it is not an acceptable survey monument. Revise plat appropriately. DS 2-03.6.5., DS 2-03.6.5.C.6.

16. There is a "Cable Television Service Agreement and Easement Docket 11921, Page 2413," that is not shown on the plat. Is this easement going to be abandoned? Please clarify. Provide delineation of the easement or provide abandonment recordation information on the plat view.

17. Provide (dedicated) 2' along the east side of Glenn St. for ROW. MS&R shows a 64' width and 32' from centerline of Glenn Street. Plat shows 30' from centerline to existing property line.

18. Remove the handicap symbols from the plat.
01/17/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 17, 2007

Doug Schneider
Rick Engineering Company
1745 East River Road, Suite 101
Tucson, Arizona 85719

Subject: S06-257 Hidden Glenn Condominiums Final Plat

Dear Doug:

Your submittal of December 7, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

8 Copies Revised Final Plat (Commercial Building, TEP, Fire, Zoning, Addressing, Real Estate, Engineering,DSD)

2 Copies Boundary Closure Calculations (Engineering, DSD)

2 Copies LUC Affidavit (Zoning, DSD)

3 Copies CC&R's (Zoning, Engineering, DSD)

2 Copies Title Report (Engineering, DSD)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 322-6956
12/07/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/11/2006 CHRISTY FOREMAN BUILDING-COMMERCIAL REVIEW Denied The following expired permits need to be resolved.
T02BU00713
T02BU00715
T02CM00231
T02BU00781
Please see permit counter to resolve expired permits.
12/20/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: HIDDEN GLENN CONDOS
S06-257



Tucson Electric Power Company (TEP) has reviewed the final plat
submitted December 7, 2006. TEP is unable to approve the plat at this
time.



In order for this TEP to approve the final plat, the following is
required:

* Add the following paragraph to the dedication:

"An easement is granted for the purpose of access, installation
replacing repairing and maintenance of electrical meters, cable and
conduits, which grouped electrical meters are attached to the exterior
walls."



Show these requirements on the re-submittal of the plat and submit one
copy of the plat to the City of Tucson for TEP's final approval.



Please contact me at (520) 917-8745 if you have any questions.



Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
12/22/2006 JIM EGAN COT NON-DSD FIRE Denied Provide permit information on the "Stucco Arch". Twenty feet wide and fifteen feet tall are required for fire access to rear buildings.