Plan Number: S06-228
Parcel: Unknown

Address:
60 N HARRISON RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-228
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/16/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/12/2007 STEVE SHIELDS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Broadway-Harrison Shopping Center
S06-228
Final Plat

TRANSMITTAL DATE: April 12, 2007

DUE DATE: April 13, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C\planning\cdrc\finaplat\S06-228fp-3rd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
05/17/2007 ANY ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: May 17, 2007
CDRC/Zoning Manager
SUBJECT: Broadway-Harrison Shopping Ctr, 60 N. Harrison Final Plat S06-228 (Third Review)
T14S, R15E, Section 11

RESUBMITTAL REQUIRED: Final Plat.

The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies of the FP.
2. This comment pertains to comments 2 and 3: Per the COT flood hazard maps, the Wrightstown Wash at the Eastside of the property has a flow in excess of 300 cfs. A flow of over 100 cfs is considered regulatory flow. The COT flood hazard maps also show an amount of break out overflowing onto the subject property. The floodplain limits must be shown on the plat. Perhaps a meeting to discuss the floodplain requirements for the FP may be in order. Contact me at the phone number listed below to make an appointment.
3. Show required setbacks, such as erosion hazard, drainage etc……per D.S. 2-03.6.4.E.
4. Show the limits of the 100-yr. Floodprone area in a surveyable and readily retraceable……….per D.S. 2-03.6.4.F.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax,
C:/60 N. Harrison Road FP rev 3
05/18/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 18, 2007

Kent Miller
KDM Surveying Services
12431 North 65th Street
Tucson, Arizona 85754

Subject: S06-228 Broadway-Harrison Shopping Center Final Plat

Dear Kent:

Your submittal of March 19, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Final Plat (Engineering, DSD)








Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (480) 998-0138
fpresubmittal