Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S06-228
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 11/16/2006 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: BROADWAY HARRISON SHOPPING CENTER S06-228 Tucson Electric Power Company (TEP) has reviewed the final plat submitted November 3, 2006. TEP is unable to approve the plat at this time. In order for this Company to approve the final plat, the following will be required. * Depict the Public Utility Easement recording information for Easement recorded 06/11/03, Docket-12069 at Page-622. Submit two copies to the Final Plat for TEP's final approval. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent Land Management Tucson Electric Power Co. Unisource Energy Gas & Unisource Energy Electric PH: (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 12/01/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Denied | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor's Office Mapping Department DATE: December 1, 2006 RE: Assessor's Review and Comments Regarding Final Plat S06-228 BROADWAY-HARRISON SHOPPING CTR. T141511 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements.(SEE COMMENTS) _______ Plat does not meet Assessor's Office requirements. COMMENTS: PLEASE MAKE THE FOLLOWING ADJUSTMENTS BEFORE RECORDING: 1. THE TITLE BLOCK SHOULD BE LOCATED IN THE LOWER RIGHT HAND CORNER OF EACH SHEET. 2. THE TOTAL NUMBER OF LOTS SHOULD BE LISTED AFTER THE NAME OF SUB IN THE TITLE BLOCK THEN REFERENCE THE RESUB INFO. 3. THE PARCEL LINES SHOULD BE HEAVIER THAN THE OTHER LINES. THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390 ROSANNA WERNER |
| 12/04/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-228 BROADWAY-HARRISON SHOPPING CTR/FINAL PLAT DATE: 12/04/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Add Section, Township and Range to Location Map. Label section corners. Provide Title Block that includes Project Title, Number of Lots to be platted and brief Legal Description. Should these be called out as Lots and not Parcels? es |
| 12/06/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Broadway-Harrison Shopping Center S06-228 Final Plat (1st Review) TRANSMITTAL DATE: December 4, 2006 DUE DATE: December 4, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. An applicant has one (1) year from the date of application to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before November 03, 2007. 2. Provide the last approved site plans for the entire center. 3. D.S. 2-03.6.1.D Provide a location map which meets the minimum requirements of D.S. 2-03.6.1.D, show the subject property approximately centered in the one (1) square mile area, identify conditions within the square mile area, such as major streets and watercourses, section, township and range, north arrow and scale. 4. D.S. 2-03.6.1.G Place the words "BOOK___________PAGE_________" in both the upper and lower right corners outside the margin lines. The blanks will be completed by the Pima County Recorders Office at the time of recordation. 5. D.S. 2-03.6.1.H A title block with the following information is to be provided in the lower right corner of each sheet. 1. Subdivision name; number of blocks, lots and/or units; common area. 2. Legal description by section, township, and range 3. If the final plat is a resubdivision of a previously recorded plat, indicate the title and the book and page reference of the existing subdivision. 6. D.S. 2-03.6.1.J Line weights will reflect the nature of the line, e.g., right-of-way lines will be more prominent than lot lines or easements, and drainageways will be in heavy solid lines except at street crossings. It is difficult to distinguish between items on the plat. Revise line weights and provide a legend, which defines what each line type is. 7. D.S. 2-03.6.1.K Place the S06-228 subdivision case number in the lower right corner of the plat next to the title block. 8. D.S. 2-03.6.1.K Place the C9-77-33 zoning case number in the lower right corner of the plat next to the title block. 9. D.S. 2-03.6.2.A Provide as a general note "THE GROSS AREA OF THE SUBDIVISION IS ____ ACRES." 10. D.S. 2-03.6.2.B Provide as a general note "THE TOTAL NUMBER OF LOTS IS THREE (3)." 11. D.S. 2-03.6.2.H Provide as a general note "THERE WILL BE NO FURTHER DIVISION OF LOTS WITHOUT THE EXPRESSED APPROVAL OF THE CITY OF TUCSON." 12. D.S. 2-03.6.2.J Provide as a general note "THIS SUBDIVISION IS SUBJECT TO ORDINANCE NO. 4748 WHICH ESTABLISHED ZONING IN THE SOLANO ESTATES/HALCY ACRES ANNEXATION AREA." 13. D.S. 2-03.6.3.D Provide approval and recording data blocks. The current City Clerk is "KATHLEEN S. DETRICK" and the current Pima County Recorder is "F. ANN RODRIGUEZ". See Development Standards for the required approval and recording data blocks 14. D.S. 2-03.6.3.E Provide assurance block. See Development Standards for the required assurance block. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C\planning\cdrc\finaplat\S06-228fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, tentative plat, final plat, CC&R's and additional requested documents. |
| 12/07/2006 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | |
| 12/11/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-228 Broadway-Harrison Shopping Ctr.: Final Plat Review - No comment. |
| 12/15/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | December 15, 2006 To: Kent Miller, KDM Surveying Services Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Michael J.Harrington (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Albertsons Center Phase II Final Plat - 1st Submittal S06-228 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. This project will be tributary to the Ina Road Water Pollution Control Facility via the Tanque Verde Interceptor. The on-site sewers are existing and private. No new sewers are proposed. All Sheets: Add the subdivision case number, S06-228, to the title block of each sheet. This number should be shown larger or bolder than any cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision. All Sheets: Add the appropriate cross-reference numbers near the title block of each sheet. These numbers should be shown smaller or less bold then the current case number. There is no dedication block shown on this submittal. The dedication will be reviewed with the next submittal. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 12/18/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: December 18, 2006 CDRC/Zoning Manager SUBJECT: Broadway-Harrison Shopping Ctr, 60 N. Harrison Rd. Final Plat S06-228 (First Review) T14S, R15E, Section 11 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. The final plat does not meet the submittal requirement per the City of Tucson Development Standards. See Development Standards chapter 2-03.6.0 for final plat format and content. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/60 N. Harrison Road FP rev |
| 12/19/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 19, 2006 Kent Miller KDM Surveying Services 12431 North 65th Street Tucson, Arizona 85754 Subject: S06-228 Broadway-Harrison Shopping Center Final Plat Dear Kent: Your submittal of November 3, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 7 Copies Revised Final Plat (TEP, Assessor, Addressing, Zoning, Wastewater, Engineering, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (480) 998-0138 fpresubmittal |