Plan Number: S06-218
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-218
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/11/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/11/2007 FRODRIG2 PIMA COUNTY WASTEWATER Denied October 10, 2007

To: Joaquin Rincon, Steve Corrales Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Limberlost Court Condominiums
Units 1-40 & Common Area "A"
Tentative Plat – 2nd Submittal (retract)
S06-218

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Tim Rowe of PCWMD has discovered a problem with your proposed abandonment of the existing public sewer (SDG-28). As a result he has requested that we retract the previous submittal review letter dated October 4, 2007. The building at 4144 N Oracle Rd. per our records is currently being served by the sewer you have proposed abandoning. Please contact Mr. Tim Rowe of PCWMD @ 740-6547 to discuss possible solutions.

This office will require a revised set of blue lines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the tentative or preliminary plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the third (3rd) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of blue lines and response letter.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
10/12/2007 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Limberlost Court Condominiums
S06-218
Tentative Plat/Development Plan (3rd Review)

TRANSMITTAL DATE: October 12, 2007

DUE DATE: October 31, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project has been reviewed as a tentative/development plan. Sections 4.1.7.1 & 5.3.8.2, of the LUC, permit a maximum of one year from the date of application to obtain approval of a tentative/development plan. If, at the end of that time, the tentative/development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is October 22, 2007

2. This comment was not fully addressed. Add the DSMR number, DS06-54, to each sheet in the lower right hand corner next to the title block. Zoning acknowledges that a DSMR (DS06-54) has been approved with conditions. Please note that a general note must be added to the tentative plat which states the DSMR case number, date of approval, modifications granted and conditions imposed. In addition, the case number must be added to each sheet of the tentative plat, landscape plans, and NPPO plans, in the lower right corner of the title block. D.S. 2-03.2.4.D.3 & D.S. 2-08.4.1.B There are numerous areas through out the development where sidewalks area required but not provided adjacent and parallel to the PAAL on the side where buildings are located. Between the buildings located southeast of what appears to be a pool and the hammerhead located along the east property line.

3. Based on the elevations provided the "BUILDING HEIGHT, MAXIMUM PROPOSED" is incorrect. This should read 22'-6". The proposed setback to the C2 zoned adjacent property should be 22'-6". The proposed setback to the R2 zoned adjacent property should be 16'-10". Revise the setback requirement information on sheet 1 and the setback information on sheet 3. It does not appear that unit 22 will meet the 16'-10" setback along the east property line. It does not appear that units 17, 18, 19, 20, 21, 22 & 23 will meet the 22'-6" setback along the south property line. It does not appear that units 23, 24, 25, 26, & 27 will meet the 22'-6" setback along the west property line. Additional comments maybe forth coming.


If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\tentativeplat\S06-218tp-3rd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative/development plan and additional requested documents.
10/16/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Correct note 10 on Sheet of NPPP. PIP plants may not be damaged or removed. If any are damaged or destroyed the plan must be revised due to the change to preservation credits.
"If any TOS plants do not survive the transplant process, mitigation with a plant of the same size and species is required".

2:1 mitigation applies only plants approved as RFS on the plan. DS 2-15.4.D

We suggest that use use the above section (in quotes) to address the replacement requirements as it is based on applicable codes and standards.

2) Revise the landscape plan to include the number of Prosopis velutina resulting from the NPPP calculations.

3) . Keynote 9 on the T3 includes the term "cmu wall" and indicates that it will be constructed on three sides of the property. Revise the note if necessary to clarify the proposal.
Clarify the location of the cmu wall for the southern portion of the east property boundary.

4) Add the following note to the landscape plans: "Trees and shrubs are to be selected and located so that, at maturity, they do not interfere with existing on-site or off-site utility service lines or utility easements or with solar access." LUC 3.7.2.6.B, DS 2-07.2.2.E.1

There may be potential conflicts depending on the nature of the utility installations.

5) The landscape plans received for review were too blurry read. The plant symbols and much of the text was illegible. Please submit a clear copy with any resubmittals.


RESUBMITTAL OF ALL PLANS IS REQUIRED
RESUBMITTAL OF ALL PLANS IS REQUIRED.
10/22/2007 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-218 LIMBERLOST COURT CONDOMINIUMS/REVISED TENTATIVE PLAT
DATE: October 19, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Include all sections on Location Map.

Add Stone to Av. or delete on Location Map.

Change 29055 to 60084 on Location Map.

Include lot dimensions.

All street names will require Spanish approval.

jg
11/15/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

November 15, 2007

Joaquin Rincon
Steve Corrales Engineering Corp.
1008 West Saint Mary's Road
Tucson, Arizona 85705

Subject: S06-218 Limberlost Court Condominiums Tentative Plat/Development Plan

Dear Joaquin:

Your submittal of October 4, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Tentative Plat (Wastewater, Zoning, Landscape, Addressing, Engineering, DSD)

4 Copies Revised Landscape Plan (Zoning, Landscape, Engineering, DSD)

2 Copies Revised NPPO Plan (Landscape, DSD)

2 Copies Revised Drainage Report (Engineering, DSD)

THE REVIEW PERIOD FOR THIS TENTATIVE PLAT HAS EXPIRED. PLEASE CONTACT ME TO DISCUSS WHAT WILL BE REQUIRED TO EXTEND THIS REVIEW CYCLE.

hould you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 622-2554
11/15/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator DATE: November 15, 2007

SUBJECT: Engineering review of the Limberlost Court Condominiums Tentative Plat. The activity number is S06-218.

SUMMARY: The Tentative Plat and Drainage Report were received by Engineering on October 4th, 2007. Engineering has reviewed the received items and does not recommend approval of the Tentative Plat.

RESUBMITTAL REQUIRED: TENTATIVE PLAT

SUBMITTAL: REVISED DRAINAGE REPORT

GENERAL COMMENTS

1. The Drainage Report was reviewed for Tentative Plat purposes only.

2. Please include the Assurance Package with the Final Plat submittal. This package must include the original Third Party Trust, the original Amendment to Trust, a copy of the Trust Agreement, a copy of the Deed, and a Title Report.

3. Include a copy of the CC&Rs with the Final Plat submittal. The specific maintenance notes specified in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.3.2 must be included on the Final Plat or in the CC&Rs. The term "owner" in the maintenance notes is to be replaced with "Homeowners Association".

4. Please provide a copy of the boundary closure calculations with the Final Plat submittal.

5. A Grading Plan and Permit will be required. Proposed grading in excess of 5,000 yards is designated "engineered grading" and a soils engineering report is required with the Grading Plan submittal. Development Standard 11-01.4.1.C. The Soils Report must also address the requirements detailed in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.2.6.

6. Proposed fills in excess of two feet above existing grade at any location in the outer one hundred feet of the developing site adjacent to residentially zoned property require the procedure outlined in Development Standard 11-01.8.1. This process must be complete prior to Grading Plan approval.

7. Proposed developments disturbing areas exceeding 1 acre are subject to AzDES requirements.

8. All proposed easements must be shown in a surveyable manner on the Final Plat.


The next submittal must address the following items:

TENTATIVE PLAT COMMENTS

1. Please see Zoning's comment regarding the DSMR. This office will not approve the tentative plat without the requested information.

2. Provide cistern symbol in the legend. Second request.

3. There appears to be a cistern in the far side SVT. Revise the plan to not show any sight obstruction within the required SVTs. Second request.

DRAINAGE REPORT COMMENTS

1. The drainage scheme has changed provide a revised drainage report to reflect the current proposal.