Plan Number: S06-205
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-205
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/18/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/26/2007 AVERA1 ENV SVCS REVIEW Denied * Enclosure detail, per development standards, requires 10 ft clear between bollards (steel post) and requires gates.
01/31/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-205
Las Sendas Subdivision
Tentative Plat Resubmittal

TRANSMITTAL DATE: January 30, 2007

DUE DATE: February 15, 2007

COMMENTS:

The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.



If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-205tpr.doc
02/02/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: LAS SENDAS

Lots 1-77

S06-205



Tucson Electric Power Company (TEP) has no objection to the tentative
plat submitted for review dated January 19, 2007.



TEP will provide a preliminary electrical design on the Approved
Tentative Plat within fifteen (15) working days upon receipt of the
plat. Additional plans necessary for preparation of the design are:
building plans including water, electrical, landscape, sidewalk and
paving plans. Also, submit the AutoCAD version of the plat on a CD or
email to lcastillo@tep.com <mailto:lcastillo@tep.com> . Should you have
any questions, please contact me at (520) 917-8745.


Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
02/02/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
02/07/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-205 Las Sendas Subdivision

(ü) Tentative Plat
( ) Development Plan
(ü) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(ü) Other - elevations (color), photos of surrounding dev.

CROSS REFERENCE: C9-05-04

NEIGHBORHOOD PLAN: Santa Cruz Area Plan, General Plan

GATEWAY/SCENIC ROUTE: Ajo Way is Gateway Route in this area

COMMENTS DUE BY: February 15, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
(ü) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
(ü) No Resubmittal Required
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other - color elevations, photos of area development

REVIEWER: J. Hershenhorn 791-4505 DATE: 2/5/07
02/08/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond February 8, 2007

To: J. Lorenzo Ortiz, Indevco A&E, Inc.

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J. Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Las Sendas (R.C.P)
Lots 1 through 77 and Common Areas "A"-"D"
Tentative Plat - 2nd Submittal
S06-205

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Capacity Response No. 06-369 letter has been received and is now in our file.

The January 2, 2007 letter authorizing you to construct 6” private sewer collection laterals in Las Sendas has been added to our file.

Item #7 of the November 16, 2006 review letter has not been addressed. I was also not able to locate an existing easement. The explanation is not needed.

Item #12 of the November 16, 2006 review letter has not been addressed. Be advised that the variance will be required prior to approval of construction plans for the public sewer relocation project.

All Sheets: Add the cross-reference numbers, C12-86-7A, C9-85-18 and CD9-85-18, near the title block of each sheet. These numbers should be shown smaller or less bold than the current case numbers.

Sheets 2 & 3: Revise Keynote #8, with a clarifying note that states something like:

SEE WASTEWATER MANAGEMENT NOTES 5 & 6

Sheets 2 & 3: Show the public and private sewer lines using different line-types, so that they can readily be distinguished from each other. Also, show and describe examples of these different line-types in the legend on Sheet 1.

Sheets 2 & 3: Revise the site plan to show:

An arrow over each reach of existing and proposed public and private sewer pipe to indicate flow direction.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
02/13/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-205 LAS SENDAS SUBDIVISION/REVISED TENTATIVE PLAT
DATE: February 8, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
02/15/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
03/05/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: March 5, 2007
SUBJECT: Las Sendas Tentative Plat- 2nd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 1425 W Ajo Way, T14S R13E Sec34/35, Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: S06-205


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Tentative Plat, Landscape Plans, Drainage Report, and Geotechnical Report. The Drainage Report was reviewed for Tentative Plat purposes only. The Tentative Plat is not approved at this time. The following items need to be addressed:


TENTATIVE PLAT:

1) DS Sec.2-03.2.4 C: Revise the Title Block on Sheets 1-4 to clarify all uses within Common Area "B." Common Area "B" per the drainage report is a landscape area that is used as a retention/drainage area for concentrating flow into Retention Basin A. Revise the description for Common Area "B" within the Title Block and verify that the same descriptions are used within the Covenants, Conditions and Restrictions (CCRs).

2) DS Sec.2-03.2.4.F: Revise the sidewalk label typo on Sheet TP-2 of the Tentative Plat. The labeled 6-foot sidewalk should be called out not a 6-foot "Shoewalk."

3) DS Sec.2-03.2.4.J: Provide easements for all utilities with recordation information or provide the description for each utility in their respective Common Area, verify that the CCRs match the Common Area descriptions. Specifically the sewer and water lines fall within Common Area "A," which is dedicated on the Tentative Plat as a PAAL only. Provide the proposed easements for all utilities that fall within Common Area "A."

4) DS Sec.2-03.2.4.L: Revise the Tentative Plat, in conjunction with the submitted Drainage Report, to reflect the correct water surface elevation (WSEL) within Common Area "D" (Retention Basin B). The Tentative Plat, Sheet TP-3, shows a WSEL of 2460.25 for Retention Basin B. The correct WSEL of 2410.25 should be labeled as called out in the detail on Sheet TP-4 and within the submitted Drainage Report.

5) DS Sec.10-02.0.14.3.2: Revise Drainage Note #6 under the General Notes to include the following wording to the inspection and maintenance statement; "All inspections and maintenance must conform to the manufactures recommendations and per the submitted Drainage Report."

6) DS Sec.11-01.9: Revise the Tentative Plat to provide the required 2-feet setback from all property boundaries to the proposed limits of grading, top and toe of fill slopes, detention/retention basins, and associated erosion protection. The plan view on the Tentative Plat shows that the limits of grading encroach within the required 2-feet setback. Provide sufficient room to allow for the 2-feet setback from property lines to top of fill slopes and associated erosion protection. Specifically the proposed top of the sediment basin encroaches within the required 2-foot setback.


GRADING PLAN:

7) DS Sec.11-01.2.1: For future reference a grading permit will be required for this project. A grading permit may not be issued prior to Tentative Plat approval.

8) Please ensure the grading plan is consistent with the Tentative Plat, Drainage Report, and Geotechnical Report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf.

9) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with grading plan submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html.


GENERAL COMMENTS:

Provide a revised Tentative Plat and revised CCRs at re-submittal.

The revised Tentative Plat must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Tentative Plat.

If you have any questions, I can be reached at 791-5550, extension 1189.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
03/09/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 9, 2007

J. Lorenzo Ortiz, P.E.
INDEVCO A&E, Inc.
5995 East Grant Road, Suite 111
Tucson, Arizona 85712

Subject: S06-205 La Sendas SubdivisionTentative Plat

Dear Mr. Ortiz:

Your submittal of January 19, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Tentative Plat (ESD, Engineering, Wastewater, DSD)

2 Copies Revised Landscape Plan (Engineering, DSD)


Staff from Zoning, DSD Engineering, and Traffic met and determined that the access ways in this subdivision will be private streets and maybe modified with a DSMR. Should there be conflict in the on-line comments, please revise plat as if the proposed access ways are streets.


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 545-0092
Tp-resubmittal