Plan Number: S06-204
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-204
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
05/23/2007 LAITH ALSHAMI ENGINEERING REVIEW Approv-Cond Laith Alshami, Engineering and Floodplain Review, 05/23/2007,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Pavilions
S06-204, T15S, R15E, SECTION 01

RECEIVED: Tentative Plat and Drainage Report on May 21, 2007

The subject submittal has been reviewed. The Drainage Report is acceptable for Tentative Plat purposes and it is hereby approved. Additional drainage information might be required in a revised drainage report with the Grading Plan. The Tentative Plat is recommended for a conditional approval pertaining to Engineering and Floodplain review. Address the following conditions on the Tentative Plat Mylar and submit a detailed response letter that explains the revisions that were made and references the exact location on the Tentative Plat where the revisions were made:

1. Replace the word "FPR" with the word "FOR" in General Note #37.
2. Add, in General Note #37, lot number 1 to the list of lots that are impacted by the City of Tucson Floodplain Regulations (D.S. 2-03.2.2.C.2.a.).
3. Provide the bearing for the tie to the basis of bearing (D.S. 2-03.2.3.A).
4. Provide additional water surface elevations, at several locations, for all flows of 100-cfs or more (D.S. 2-03.2.3.J.1 and D.S. 2-03.2.4.L.6.).


RESUBMITTAL REQUIRED: Revised Tentative Plat Mylar
06/01/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approved June 1, 2007

To: Robert Suarez, RS Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Pavilions, Lots 1-17
Tentative Plat – 3rd Submittal
S06-204

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
06/06/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-204
Pavilions
Tentative Plat Resubmittal

TRANSMITTAL DATE: June 6, 2007

DUE DATE: June 18, 2007

COMMENTS:

The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.




If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-204tpr1.doc
06/06/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-204 PAVILIONS/TENTATIVE PLAT
DATE: June 6, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

TENTATIVE PLAT IS APPROVED WITH THE FOLLOWING CONDITION:
1.) PLEASE PROVIDE A COPY OF THE RECIPROCAL ACCESS AGREEMENT AND A COPY OF THE CCR’S PRIOR TO MY APPROVAL OF THE FINAL PLAT.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***


jg
06/06/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-204 PAVILIONS/TENTATIVE PLAT
DATE: 11/02/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***


ES
06/08/2007 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Obtain approval for Houghton Road right-of-way improvements and landscaping from the Departrment of Transportation in compliance with the TDOT standard.

Add the following note to the landscape plans:
Approval of the tentative plat landscape plans constitutes approval of the on-site landscaping only. A separate plan, review and permit are required for work in the public right-of-way/street. Note: private irrigation lines are not allowed within the public right-of-way"
06/12/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved >>> Andy Steuart 06/28/2007 2:24 PM >>>
Ref.: My 6/15/2007 Msg., Same Subject

S06-204 Pavillions: Resubmittal - CDRC - Tentative Plat Review - Per 6/26/07 discussion w/ Jerry Pelland, RS Engineering, above Reference comments are incorporated in the Mylar master. It is understood legal counsel is in the process to change the sewer easement configuration and outcome will be correctly annotated on the Mylar when information is available. In the spirit of cooperation, request R.E. comments be changed to "No comment" for review of this tentative plat.
06/12/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-204 Pavilions 06/11/07

( X ) Tentative Plat
() Development Plan
( X ) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
( ) Other

CROSS REFERENCE: C9-05-02

NEIGHBORHOOD PLAN: Civano Master PAD – PAD 12

GATEWAY/SCENIC ROUTE: Scenic Route

COMMENTS DUE BY: June 18, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
( X ) No Additional Comments - Complies With Planning Comments Submitted on: 3/2/07
( X ) No Resubmittal Required:
( X ) Tentative Plat
() Development Plan
( X ) Landscape Plan
( ) CC&R’s

REVIEWER: JBeall 791-4505 DATE: 6/11/07
06/15/2007 CDRC1 COT NON-DSD REAL ESTATE Approved >>> Andy Steuart 06/28/2007 2:24 PM >>>
Ref.: My 6/15/2007 Msg., Same Subject

S06-204 Pavillions: Resubmittal - CDRC - Tentative Plat Review - Per 6/26/07 discussion w/ Jerry Pelland, RS Engineering, above Reference comments are incorporated in the Mylar master. It is understood legal counsel is in the process to change the sewer easement configuration and outcome will be correctly annotated on the Mylar when information is available. In the spirit of cooperation, request R.E. comments be changed to "No comment" for review of this tentative plat.
06/15/2007 CDRC1 COT NON-DSD REAL ESTATE Approved >>> Andy Steuart 06/28/2007 2:24 PM >>>
Ref.: My 6/15/2007 Msg., Same Subject

S06-204 Pavillions: Resubmittal - CDRC - Tentative Plat Review - Per 6/26/07 discussion w/ Jerry Pelland, RS Engineering, above Reference comments are incorporated in the Mylar master. It is understood legal counsel is in the process to change the sewer easement configuration and outcome will be correctly annotated on the Mylar when information is available. In the spirit of cooperation, request R.E. comments be changed to "No comment" for review of this tentative plat.
06/21/2007 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved >>> Andy Steuart 06/28/2007 2:24 PM >>>
Ref.: My 6/15/2007 Msg., Same Subject

S06-204 Pavillions: Resubmittal - CDRC - Tentative Plat Review - Per 6/26/07 discussion w/ Jerry Pelland, RS Engineering, above Reference comments are incorporated in the Mylar master. It is understood legal counsel is in the process to change the sewer easement configuration and outcome will be correctly annotated on the Mylar when information is available. In the spirit of cooperation, request R.E. comments be changed to "No comment" for review of this tentative plat.
06/21/2007 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: June 21, 2007

TO: DSD_CDRC@ tucsonaz.gov

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov


SUBJECT: S06-204 Pavilions: Tentative Plat Review(5-21-07)

Approved.
07/05/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#170801 April 19, 2007




Dear Robert Suarez :

SUBJECT: PAVILLIONS TENTATIVE PLAT (Resubmittal)
S06-204


Tucson Electric Power Company has reviewed and approved the development plan submitted April 19, 2007 It appears that You have discussed converting the existing Overhead Electric Faciilities to underground with your area Designer. If you decide not to convert the existing overhead lines to underground, any poles or equipment in conflict that requires relocation will be billable. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer Nancy DiMaria at (520) 918-8267, should you have any questions.


Sincerely,



Henrietta Noriega
Office Specialist
Design/Build
hn
Enclosures
cc: N. DiMaria, Tucson Electric Power
P. Gehlen, City of Tucson (Email)
07/06/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 6, 2007

Robert M. Suarez
R S Engineering, Inc.
140 North Tucson Blvd.
Tucson, Arizona 85785716

Subject: S06-204 PavilionsTentative Plat

Dear Robert:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off:

1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO.

Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3.

THE TENTATIVE PLAT MYLARS MUST BE SHOWN TO AND APPROVED BY CITY OF TUCSON REAL ESTATE PRIOR TO SUBMITTAL TO THE CDRC OFFICE. WRITTEN DOCUMENTATION (E-MAIL IS OKAY) THAT CONDITIONS OF APPROVAL HAVE BEEN MET ON THE MYLAR.

Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 791-9405