Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S06-203
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/11/2007 | FRODRIG2 | START | PLANS SUBMITTED | Completed | |
06/11/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | June 11, 2007 To: Steve Gregor, Gregor Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Tom Porter, Sr. CEA Development Review Division (Wastewater) Pima County Development Services Department Subject: Venado Vista Lots 1-19 and Common Area "A" and “B” Tentative Plat – 3rd Submittal S06-203 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. You are proposing the construction of a private sewer collection system in a residential subdivision. This type of sewer now necessitates prior written authorization, pursuant to PCWMD Director, Michael Gritzuk’s letter to PCDSD Director, Carmine DeBonis, dated March 13, 2006, regarding Private Sewers and Public Pump Stations. This is the 2nd request. You may call Mr. Tim Rowe, P.E. ( 740- 6547) of the PCWMD if you have any questions concerning approval of the private sewers. The 8” sewer line shown south of New MH #13 has to have MH’s instead of cleanots @ all bends and at the end of the terminal segment symbolized by Keynote #44 The recordation information for the sewer easements shown on the property needs to be shown on plan. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the tentative plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the fourth(4th) submittal. A check for the review fee of this submittal in the amount of $78.00(made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Tom Porter (520-740-6579) cc: Project File |
06/11/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | June 18, 2007 To: Steve Gregor, Gregor Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Tom Porter, Sr. CEA Development Review Division (Wastewater) Pima County Development Services Department Subject: Venado Vista-Revised Comments Lots 1-19 and Common Area "A" and “B” Tentative Plat – 3rd Submittal S06-203 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. An authorization for private sewer request has been made by Tim Rowe of PCWWM for Director Michael Gitzuk’s signature. The authorization should be ready in about one week. You may call Mr. Tim Rowe, P.E. ( 740- 6547) of the PCWMD if you have any questions concerning approval of the private sewers. The 8” sewer line shown south of New MH #13 should be changed to 6”. The recordation information for the sewer easements shown on the property needs to be shown on plan. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative or preliminary plat. The required revisions may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Tom Porter (520-740-6579) cc: Project File |
07/05/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The Landscape Section recommend approval of the applications subject to compliance with the following: 1) A NPP plan is required for the offsite sewer proposed on the tentative plat prior to approval. LUC 3.8.3.1 Revise the plans to include provisions for irrigation and maintenance for plant establishment. 2) LUC 3.8.6.7.B, Fencing shall remain in place for the duration of construction activities. Revise the Native Plant Preservation Plan fencing notes to include this imporatnt element of NPPO and ERZ compliance. LUC 2.8.6.6.C 3) Revise the calculation for the NUOS area on NPPP-1 and ERZ-NPPO to correspond. The values differ on the current plans. 4) Revise the plat and associated plans to include include landscape easements for mitigation areas proposed on individual lots. Clarify maintenance plans and responsibilities. Include provisions for maintenance of the mitigation areas in the CC&R's. RESUBMITTAL OF ALL PLANS IS REQUIRED |
07/10/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S06-203 Venado Vista Tentative Plat TRANSMITTAL DATE: July 10, 2007 DUE DATE: July 10, 2007 COMMENTS: The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-203tpr1.doc |
07/31/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | September 13, 2007 Bob Tenor Gregor Engineering, Inc. 5232 East Pima Street, Suite A Tucson, Arizona 85712 Subject: S06-203 Venado Vista Tentative Plat Dear Bob: The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off: 1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO. 2 CD that contains all of the drainage/hydology and other reports submitted for the review and approval of this plat. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. THE MYLARS MUST BE REVIEWED AND APPROVED BY PIMA COUNTY WASTEWATER PRIOR TO SUBMITTAL TO THE CDRC OFFICE. A WRITTEN APPROVAL IS REQUIRED (E-MAIL IS SUFFICIENT). MYLARS MAY NOT BE SUBMITTED UNTIL THE OVERLAY APPLICATION HAS BEEN APPROVED AND APPEAL PERIOD HAS EXPIRED. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 319-1181 |
07/31/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved |