Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S06-194
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/15/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/16/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 03/29/2007 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S06-194 Vista Verde Subdivision 03/28/07 (XXXX) Tentative Plat () Development Plan (XXXX) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: NEIGHBORHOOD PLAN: Houghton East Neighborhood Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 104/12/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (XXXX) Resubmittal Required: (XXXX) Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: drcorral 791-4505 DATE: 03/26/07 Please add a note to the general notes section stating the following: Elevation of the homes along the eastern tier of the site shall not exceed 20 feet in height. The unit at the southeast corner of the site shall be limited to one story. Please add a note to the general notes section stating the following: no two homes with the same façade or color scheme shall be placed next to one another. |
| 04/05/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S06-194 Vista Verde Subdivision Tentative Plat Resubmittal TRANSMITTAL DATE: April 4, 2007 DUE DATE: April 12, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. DS 3-01.10.0, Figure 1 requires that six (6) inch vertical curbs to be used when parking lanes are not provided as an entrance road. To be able to modify the cross section a DSMR must be applied for and approved for details 1/2 and 4/2. The tentative plat cannot be approved until this is completed. 2. The total dimension of section 1/2 is incorrect. Either move the right-of-way six (6) inches to the edge of the PUE or increase the total right-of-way width to fifty and one-half (50.5) feet. DS 3-01.10.0 figure 1 & 2 3. Please provide a detail as to how accessibility is for lots 1-3. Barrier free access, as applied under this criterion, is access from a street and/or parking space to the front door of a unit. DS 2-10.3.1.D & LUC 3.6.1.4.A.5 4. In Article 6, which discusses NUOS, please remove the following: a) From Sec. 6.1 remove "except for driveway improvements, which may occur in an NUOS area." b) From Sec. 6.2 remove first sentence, which relates to construction damage that might occur due to improvements. It is the opinion of the Landscape Planner that this would allow such disturbance and encourages intrusion into the designated NUOS. The NUOS area is required to be fenced off and inspected by landscape staff. Please contact Joseph Linville, 791-5608 for further clarification. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-194tpr.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat and additional requested documents. |
| 04/09/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Denied | April 9, 2007 ACTIVITY NUMBER: S06-194 PROJECT NAME: Vista Verde Subdivision PROJECT ADDRESS: Houghton/Speedway PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering does not recommend approval of the Tentative Plat; therefore a revised Tentative Plat is required for re-submittal. The following items must be revised or added to the plat. 1. Include a response letter with the next submittal that states how all comments have been addressed. 2. Comment number 8 from the previous traffic engineering comments was not addressed. 'A Traffic Statement is required per Annexation Conditions #1.D of Ordinance No. 6176 adopted by Mayor and Council February 11, 1985. The Traffic Statement should address the need for any off-site improvements for this proposed development (i.e. left/right turn lane warrants). Therefore this plat will not be approved until Traffic is in receipt of the required Traffic Statement. To prevent delay in the review process Traffic will accept a TIA as a separate submittal.' Address this comment and ensure that considerations of any off site improvements are discussed in the report. If you have any questions, I can be reached at 791-4259 x305 or Jose.Ortiz@tucsonaz.gov |
| 04/10/2007 | JIM EGAN | COT NON-DSD | FIRE | Denied | Some of the building locations shown on the revised plan have portions of the buildings over 150 feet from the fire lane. The structures would need to have automatic fire sprinklers if they cannot be moved closer to the street. |
| 04/11/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-194 VISTA VERDE SUBDIVISION/REVISED TENTATIVE PLAT DATE: 4/11/07 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Correct Whispering Rabbit Trail to Whispering Rabbit Place. es |
| 04/11/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-194 VISTA VERDE SUBDIVISION/REVISED TENTATIVE PLAT DATE: 4/24/07 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: Approved with the following condition: ON FINAL PLAT: 1.) Correct Whispering Rabbit Trail to Whispering Rabbit Place. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 04/12/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | 1) Include Common Area 'B' in the title. 2) Note 4 on the tentative plat under Hillside Development Zone is incorrect. Reference Hillside Site Improvement Standard DS 9-04.0 |
| 04/18/2007 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-194 Vista Verde: Subdivision: Resubmittal - CDRC - Tentative Plat Review - No comment. |
| 04/19/2007 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: April 18, 2007 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov CC: SUBJECT: S06-194 Vista Verde Subdivision: Tentative Plat Review(3-15-07) Approved. |
| 04/27/2007 | FRODRIG2 | PDEQ | PIMA COUNTY DEPT OF ENVIRONMENTAL QUALITY | Approved | Comments on file. |
| 05/23/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 23, 2007 Kent Delph Delph Engineering Inc. 1660 North Alvernon Way Tucson, Arizona 85712 Subject: S06-194 Vista Verde Subdivision Tentative Plat Dear Kent: Your submittal of September 14, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 5 Copies Revised Tentative Plat (Fire, Zoning, Traffic, DUPD, DSD) 3 Copies Revised Landscape Plan (Zoning, DUPD, DSD) 2 Copies Traffic Impact Analysis/Traffic Statement (Traffic, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 326-7508 |