Plan Number: S06-191
Parcel: Unknown

Address:
320 W IOWA ST

Review Status: Completed

Review Details: RESUBMITTAL- RECORD OF SURVEY

Plan Number - S06-191
Review Name: RESUBMITTAL- RECORD OF SURVEY
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/08/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
02/22/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-191
Liberty Corners
Record of Survey Resubmittal

TRANSMITTAL DATE: February 22, 2007

DUE DATE: March 6, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Docket and Page number must be filled in on the record of survey and a copy of the recorded easement abandonment documents must be provided prior to approval of the record of survey.


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\finalplat\S06-191fpr.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Additional requested documents.
03/01/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-191 LIBERTY CORNERS/RECORD OF SURVEY
DATE: 3/01/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.






ES
03/01/2007 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-191 Liberty Corners: Resubmittal - Record of Survey - Request the following:
-Note dedication of R/W for 25' radius spandrels @ the corners of Lostan Ave./Iowa & Liberty Ave./Iowa.
-Improvements to accommodate T.A.R.P. well @ SWC of Subject Property, requires Environmental Management and Tucson Water's input.
-Request dedication language be included in the "Dedication" block.
-Ensure all blanks, referring to Dkt./Pg., are annotated before recording.
-Provide annotation to read "By recording of this Plat, the City of Tucson's interest in existing easements are hereby abandoned."
03/20/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: March 20, 2007
SUBJECT: Liberty Corners Record of Survey- 2nd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 320 W Iowa St, T15S R13E Sec01, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: S06-191


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Record of Survey, Title Report, and Drainage Analysis prepared by PRE Inc., dated November 14, 2006. The Record of Survey is not approved at this time. Please address the following comments:


RECORD OF SURVEY COMMENTS:

1) Provide a supplemental sheet for all information that is required but can not be shown on a Record of Survey. Specifically, the supplemental sheet must include all existing and proposed sidewalks, curbing water/sewer lines, fire hydrants, 100-year floodplain limits per the Drainage Report, and all other information that is required.

2) Revise the Record of Survey removing all floating extraneous lines and details from plan view and provide this information on a supplemental sheet. Specifically remove from the Record of Survey the references to existing concrete, existing water line, sewer line, existing sidewalk, etc. All of this information should be provided on a separate supplemental sheet. A Record of Survey should only include Horizontal references, Easements, Dedication Language, Certificate of Survey, Curve Table, and Recording Data.

3) DS Sec.2-03.11.1.C: Provide documentation that the 5-foot sidewalk with curb has been installed. Either provide photo documentation of all streets or provide the Right-of-Way Use Permit from Permits and Codes showing the installation and final inspection of the required sidewalk and curb.

4) DS Sec.2-03.11.12.A: Provide recordation information (Docket and Page) annotated in plan view for easement abandonment, as shown on the revised Record of Survey for the 20-foot public utility easement (P.U.E.) that runs down the middle of Lot 3. Lots 4, 5, and 6 also have a 15-foot P.U.E. that runs through the northeast corner of the Lots. Provide the recordation information for the abandonment of this easement in plan view as shown. Abandonment must be done prior to Record of Survey approval.

5) Provide a Note to read "By recording of this plat, the City of Tucson's interest in existing easements are hereby abandoned."

6) Verify that all improvements accommodate the T.A.R.P. well at the Southwest corner of the subject property. All improvements require Environmental Management and Tucson Water's input. Submit letter or email documentation from both entities that they do not have issues for development of this property.



GENERAL COMMENTS:

Please provide a revised Record of Survey, supplemental information, and Recordation information for Easement abandonment that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Record of Survey and recordation documentation.

For any questions or to schedule a meeting, call me at 791-5550, extension 1189.




Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
03/21/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approved March 21, 2007

To: Daniel White, Physical Resource Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Engg. Manager
Development Review Division (Wastewater)
Pima County Development Services Department

Subject: Record of Survey,
Liberty Corners, 6 Lots
Final Plat – 2nd Submittal
S06-191

The proposed Record of Survey (Final Plat) for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Final Plat as received by us on February 5, 2007.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above comments, please do not hesitate to contact me.

Sincerely,


Chandubhai C. Patel, P.E.
Phone: 520-740-6563
03/22/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 22, 2007

Daniel White
Physical Resource Engineering, Inc.
P.O. Box 36985
Tucson, Arizona 85740

Subject: S06-191 Liberty Corners Record of Survey

Dear Dan:

Your submittal of February 5, 2007, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Record of Survey (Real Estate, Engineering, Zoning, DSD),

3 Copies Recorded Easement Abandonment Documents (Zoning, Engineering, DSD)









Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 690-1769
03/22/2007 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review