Plan Review Detail
Review Status: Completed
Review Details: RECORD OF SURVEY REVIEW
Plan Number - S06-189
Review Name: RECORD OF SURVEY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 09/08/2006 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S06-189 IBARRA ROSANO DESIGN ARCHITECTS 1131 EAST ADELAIDE -------------------------------------------------------- Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by e-mail, and delete or destroy all copies plus attachments. |
| 09/11/2006 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 09/11/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | * No known landfill within 1000 feet of this development. * Lot split, Four residential lots. Access to lots off a PAAL/easement. * Approved for APC curbside service off Adelaide. APC's are to be placed and removed from the collection area on the day of service. |
| 09/14/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S06-189 1131 East Adelaide Record of Survey TRANSMITTAL DATE: September 14, 2006 DUE DATE: October 2, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Five (5) foot wise sidewalks within Adelaide Drive must be installed prior to the approval of the record of survey. Sidewalks will be labeled as existing and be dimensioned as being five (5) feet in width. DS 2-03.11.1.C 2. Please provide a proposed name of the Land Survey Exception and place in title block. DS 2-03.11.7.F.2 3. Please add symbols for property lines, existing fences, and easement lines in legend. DS 2-03.11.7.I 4. Case number S06-189 has been assigned to this record of survey (RS). Please place this number in the right corner of all sheets of the RS. DS 2-03.11.8.B.1 5. The private access easement, utility easement, and one (1) foot no access easement must be recorded prior to approval of the record of survey. Once recorded please place the recordation docket and page number on the record of survey and resubmit for approval. DS 2-03.11.11.A & DS 2-03.11.12.A 6. Please add to the record of survey the type and dimension of paving, curbs, and sidewalks. DS 2-03.11.11.B 7. Please provide the location and size of water lines, fire hydrants, storm and sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; Pima County Wastewater Management Department (PCWMD) reference number; locations of gas lines, electric and telephone lines, poles, and on-ground junction boxes, and street lights. If water mains and sewers are not located on or adjacent to the tract, indicate the direction, distance to, and sizes of those nearest the property. Show sewer line invert elevations. DS 2-03.11.11.C If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-189rs.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised record of survey and additional requested documents. |
| 09/18/2006 | FRODRIG2 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | Transportation Information for Rezoning, Subdivision, and Development Requests Delivered to: Date Delivered: Development Services - City of Tucson 9/15/2006 Case Number Project Name Average number of daily trips (ADT) forecasted as a result of the proposed development This information is provided for jurisdictional planning departments to assess the impact of the proposed residential or commercial development on surrounding traffic patterns and roads. If the forecasted daily traffic exceeds 500 average daily trips, a more detailed analysis is also provided. S06-189 1131 E Adelaide 38 Pima Association of Governments Sandra C. Holland, Data Services 177 N. Church Ave., Suite 405, Tucson, Arizona 85701-1127 (520) 792-1093 FAX (520) 620-6981 |
| 09/25/2006 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: September 22, 2006 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov CC: SUBJECT: S06-189 East Adelaide: Record of Survey Review Staff has no comments. |
| 09/25/2006 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 09/26/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 09/28/2006 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR# 169571 September 27, 2006 Ibarra Rosano Design Architects Attn: Teresa Rosano 2849 E Sylvia Street Tucson, Arizona 85716 Dear Ms. Rosano : SUBJECT: 1131 East Adelaide S06-189 Tucson Electric Power Company has reviewed and approved the development plan submitted September 5, 2006. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Please Note: Pole Unit 136 may be in a conflict with vehicular traffic along proposed ingress/egress/utility easement. Contact S. Garcia (TEP Design/Build 917-8739) to schedule site meet to review the situation in the field. Meter bases to be located per SR-405 pgs 7 & 8 of 10. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Please call the area Designer S. Garcia at (520) 917-8739, should you have any questions. Sincerely, Elizabeth Miranda Office Support Specialist Design/Build lm Enclosures cc: P. Gehlen and F. Rodriguez, City of Tucson (email) W. McElyea, Tucson Electric Power |
| 09/29/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S06-189 East Adelaide 09/29/06 () Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment (XXXX) Other – Record of Survey CROSS REFERENCE: NEIGHBORHOOD PLAN: Cragin-Keeling GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 10/02/06 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment (XXXX) Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: D. Estolano 791-4505 DATE: 9/26/06 |
| 10/02/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Denied | DATE: October 2, 2006 To: Patricia Gehlen CDRC/Zoning Manager FROM: Suzanne Bohnet, CFM Engineering Division SUBJECT: S06-189 1131 East Adelaide: Record of Survey (First Review) T13S, R14E, Section 31 RESUBMITTAL REQUIRED: Record of Survey The Engineering Division has reviewed the Record of Survey and we do not recommend approval at this time. The following review comments must be addressed. Record of Survey Comments: 1. Aerial photographs and the label "NEW SIDEWALK" on the Record of Survey indicate that sidewalks are not pre-existing. Per DS 2-03.11.1.C, a land survey exception may be applied for when all street frontage has existing sidewalks and curbs. 2. The minimum width of new sidewalks in the right-of-way is 5 feet. Please revise the dimension. 3. Please include the following symbols in the legend: 3.1. Fence(s) 3.2. Wall(s) 3.3. Property Line 3.4. Proposed Lot Lines 3.5. Street Centerline 3.6. Easement(s) line(s) 3.7. Cleanout symbol on Record of Survey needs to be shown in legend. 4. Please provide a monument description for the Quarter corner. 5. The minimum drive width is 10 feet with a minimum 12 feet between adjacent drives. Please revise as necessary. 6. Please indicate if the Access & Utility Easement, the 1' No Access Easement and the 5' Utility Easement are existing or proposed, public or private. If existing, please provide the recordation information (docket and page). 7. Please show the adjacent sewer line located on Adelaide. Also, please show the sewer line invert elevations. 8. Please provide the sight visibility triangles (SVT) for the three driveways. 9. Please provide curb access ramps at all locations where the sidewalk meets a driveway per Standard Details 207. Per ADA requirements replace the tactile grooves with truncated domes. 10. Please indicate whether the existing curb is wedge or vertical. 11. Please provide an 18" curb radius at all drive aprons. Submit a revised Record of Survey with a detailed response letter detailing how each comment has been addressed. If you have any questions, I can be reached at 791-5550 x1188 or suzanne.bohnet@tucsonaz.gov. Suzanne Bohnet, CFM Engineering Associate |
| 10/03/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | AC 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-189 1131 E ADELAIDE/RECORD OF SURVEY REVIEW DATE: October 3, 2006 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1.) Delete the address of the project. 2.) On Location Map: Change 3/37 to 37/7, change 39/86 to 61/22, 39/47 to 61/57 and add Drive to Blacklidge. 3.) Delete all adjacent parcel codes, addresses and owner information. 4.) Recorded deeds with legal descriptions will need to be provided in order to assign addresses. jg |
| 10/06/2006 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | |
| 10/12/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | S06-189 1131 East Adelaide: Record of Survey Review - No title report was provided. Concerning proposed easements for utilities, request easement(s) be dedicated for specific utilities. |
| 10/19/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | October 19, 2006 To: Teresa Rosano, Ibarra Rosano Design Architects Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Michael J.Harrington (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: 1131 E. Adelaide, Record of Survey Final Plat – 1st Submittal S06-189 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. This project will be tributary to the Roger Road Wastewater Treatment Facility via the South Rillito - West (South Line ) Interceptor. Per written guidance provided by the PCWMD Development Services Section, sufficient conveyance and treatment capacity exists in the downstream public sewerage system for this small project, and a formal capacity response letter from PCWMD is not required. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 10/20/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 20, 2006 Teresa Rosano Ibarra Rosano Design Architects 2849 East Sylvia Street Tucson, Arizona 85716 Subject: S06-189 1131 East Adelaide Record of Survey Dear Teresa: Your submittal of September 5, 2006, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Record of Survey (Addressing, Engineering, Zoning, Real Estate, DSD), Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 795-8699 |
| 10/20/2006 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review |