Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S06-186
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-186
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/19/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond September 19, 2007

To: David Little
The WLB Group

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Interstate 10 and Kolb Road. Lots 1 thru 115 and Common Areas "A", "B" and "C"
Final Plat – 2nd Submittal
S06-186


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Sheet 1: In the dedication 2nd paragraph 1st line after the word public insert the following: AND PIMA COUNTY. 2nd request. This is not a street maintenance issue but an easement issue so that the county will have access for sewer maintenance.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above-mentioned comments, please contact me.
09/24/2007 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 09/24/2007


TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Interstate 10 & Kolb Road
S06-186, T15S, R15E, SECTION 19

RECEIVED: Final Plat, CC & R's and Assurances on September 19, 2007

The subject submittal has been reviewed and it can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Tentative Plat where the revisions were made:

Final Plat Comments:

1. Revise the "City Engineer" signature line, under the Assurances Block (Sheet 1) to state " City of Tucson Development Services Engineering Administrator". The submitted Final Plat shows that the "Director" signature line has been changed.
2. Show all required setbacks as required by D.S. 2-03.6.4.E. (e.g. detention basin ponding setbacks, 100-year runoffs setbacks, etc.).
3. Show the SVT's at Herman Road and the subdivision entry roads.

CC & R's Comments:

1. The CC & R's shall specifically address the maintenance of the drainage facilities. The CC & R's should include a paragraph, which addresses the maintenance of all drainage structures in details (i.e. what facilities to be inspected and maintained, how, when, by whom, the drainage structures maintenance checklist, keeping records, and repair decisions, etc). This comment was made before, but it was not addressed properly.

Assurances Comments:

1. The project description in the "Recitals" does not match the description in the Final Plat Title Block. Revise.
2. Common Area "A" description in Item 1 of the Amendment and in both Exhibits "A" is missing the word (Drainage).
3. Provide a more recent Title Report.

RESUBMITTAL REQUIRED: Revised FP, CC & R's and Assurances
10/03/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-186
Interstate 10 & Kolb Road
Final Plat Resubmittal

TRANSMITTAL DATE: September 27, 2007

DUE DATE: October 17, 2007

COMMENTS:

The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.


If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960.

KAA S:\zoning review\karol\planning\cdrc\finalplat\S06-186fpr.doc
10/17/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: INTERSTATE 10 & KOLB

S06-186



Tucson Electric Power Company (TEP) has received the final plat
submitted September 19, 2007. TEP is unable to approve the plat at this
time. We are in the process of completing the preliminary electrical
design for this project and it will be completed approximately by the
end of this month. This design must be completed in order to review the
final plat and verify that all easement requirements have been met.
When the design completed it will be mailed out to The WLB Group and the
developer for review and approval it will also describe our easement
requirements.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
10/18/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 18, 2007

David Little
The WLB Group, Inc.
4444 East Broadway Blvd.
Tucson, Arizona 85711

Subject: S06-186 Interstate 10 & Kolb Road Final Plat

Dear David:

Your submittal of September 5, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Final Plat (TEP, Engineering, DSD)

2 Copies CC&R's (Engineering, DSD file copy)








Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 881-7492
fpresubmittal