Plan Number: S06-182
Parcel: Unknown

Address:
56 E CONGRESS ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-182
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
11/01/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
11/07/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-182
The Post
Tentative Plat Resubmittal

TRANSMITTAL DATE: November 7, 2006

DUE DATE: November 21, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please add the contour interval on each sheet preferably with the north arrow and scale.
DS 2-03.2.1.H

2. As acknowledged once detail easement information is obtained and placed on plan the development plan/tentative plat can be approved.

3. Please list as part of FAR calculations the maximum allowed FAR per LUC (10.5). Site coverage was not addressed (80% max.). Entrances on the ground floor to residential units are perceived to require site coverage calculations unless otherwise determined unnecessary by the Zoning Administrator.

4. Please revise Class 2 bicycle parking detail. Required separation between spaces measured from edge of rack is thirty (30) inches. The locating of bicycle parking within the right-of-way that is within 1,500 feet of the use will require approval from the City Engineer per LUC Sec. 3.3.6.2.C.
LUC 3.3.1 & DS 2-09.1.0

5. As acknowledged the applicant will provide a separate response letter detailing compliance with rezoning conditions prior to Development plan/tentative plat approval.

6. As acknowledged the applicant will provide prior to development plan/tentative plat approval a copy of joint use agreement of wall abutting the south boundary of property owned by the Federal Government.

7. The applicant shall provide copy of DRB approval of project prior to development plan/tentative plat approval. This along with supplemental material provided shall serve as compliance to RND Zone Design Criteria.


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-182tpr.doc


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat and additional requested documents.
11/15/2006 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Landscaping plantings in right-of-way or MS&R areas must be approved by the City Engineer or designee and comply with the City Engineer's requirements on construction, irrigation, location, and plant type. Provide verification, in writing, of any approvals obtained. Contact Gary Wittwer, DOT Landscape Architect for specific requirements. Approval of the plans by the Landscape section will be conditioned upon City Engineer approval and approval in accordance with the Administrative Design Review Procedures, 23A-32.

2) Trees with the potential for overhanging a walkway, driveway, bicycle path, parking space, or street must be of a type that, at maturity, provide a canopy with an
understory height clearance of eight (8) feet for walkways and bicycle paths, twelve (12) feet for driveways and streets, and fifteen (15) feet for loading spaces. Revise the plans as necessary to meet TDOT requirements.

3) Obtain approval for refuse pickup locations from Environmental Services. The location should meet the overhead clearance standards of 6-01.2.1.B.1.b. This may affect tree placement.
11/16/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved November 16, 2006

TO: Peggy Rau
The WLB Group

THRU: Patricia Gehlen, CDRC Manager
City of Tucson, Development Services Department

FROM: Chandubhai Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: The Post Condominiums
Development Plan/Tentative Plat – 2nd Submittal
S06-182


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Development Plan/Tentative Plat as received by us on October 25, 2006.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval to Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in an activity which may cause or contribute to air pollution.

If you have any question regarding the above comments, please do not hesitate to contact me.

Sincerely,



Chandubhai Patel, P.E.
Telephone: (520) 740-6563

Copy: Project File
11/17/2006 MATT FLICK ENGINEERING REVIEW Approved Structural design for driveway scupper to be submitted as part of the PIA process.
11/20/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-182 THE POST /REVISED TENTATIVE PLAT
DATE: November 20, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Add brief legal description to Title Block that includes Subdivision, Block, Lots, Book and Page.

Label Condo Unit Numbers (per Pima County Policy) on Final Plat.















jg
11/21/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-182 The Post 11/20/06

( X ) Tentative Plat
( X ) Development Plan
( X ) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-06-25

NEIGHBORHOOD PLAN: El Centro Redevelopment Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: November 21, 2006

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
( X ) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
( X ) Resubmittal Required:
( X ) Tentative Plat
( X ) Development Plan
( X ) Landscape Plan
( X ) Other – Elevations of Pedestrian Street Level

REVIEWER: JBeall 791-4505 DATE: 11/16/06

It should be noted that the Post project has concurrently submitted an application for development review and rezoning. Hence this development is being reviewed without finalized rezoning comments and any review comments are conditional until such rezoning comments are completed and reviewed. The applicant will need to address the following:

Although applicant has submitted an elevation of the ground floor level of the building that demonstrates a well designed street level – pedestrian experience, there seems to be missing amenities such as benches and/or street furniture which the plans call for, as well as, comments received from the DRB review. Applicant needs to add pedestrian-engaging street furniture, i.e. benches or seating areas.

Are the colors shown in the elevations the finalized color scheme? If not, then applicant could allow more flexibility by submitting a traditional color palette.

Applicant appears to have addressed the use of bicycle lockers with an appropriate amount of lockers that support potential multi-modal transportation opportunities. However, as project moves along, applicant is encourage to look for additional appropriate and potential spaces in the garage for such lockers and bicycle racks.

It should be noted that the number of bicycle parking spaces identified in General Notes section on sheet 1 of 4, is in conflict with what is shown on sheet 2 of 4. Sheet 2 identifies 4 – Class 1 spaces, and
8 Class - II spaces. Please correct General Notes section on sheet 1 of 4.

Tree plantings 5’ o.c. is not acceptable. Minimum distance between trees needs to be 12’ – 15’, depending on species, canopy span in urban areas can range from 25’ – 45’. Please address.

Paving pattern and material should be addressed by Design review Committee.

Preference is to maintain current species/specimens of Quercus virginiana as indicated in the Tucson Downtown Comprehensive Street Tree Plan (WRT 1998). If another species is to be selected, they should be Sonoran or other desert plants as recommended in the Draft Congress Street Master Plan (Wheat Scharf 2005).

Provide rezoning conditions on the Development Plan General Notes Section.
11/22/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

November 22, 2006

David Little
The WLB Group, Inc
4444 East Broadway Blvd.
Tucson, Arizona 85711

Subject: S06-182 The PostTentative Plat

Dear David:

Your submittal of October 27, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Tentative Plat (Landscape, Zoning, Addressing, DUPD, Real Estate, DSD)

4 Copies Revised Landscape Plan (Landscape, Zoning, DUPD, DSD )

2 Copies Color Elevations (DUPD, DSD)


Once the rezoning conditions are adopted by the Mayor and Council, additional review agencies may need to see the revised plans. Please provide a copy of the rezoning conditions to the CDRC office once adopted.


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 881-7492
Tp-resubmittal
11/22/2006 PGEHLEN1 COT NON-DSD REAL ESTATE Denied S06-182 The Post: Resubmittal - CDRC - Tentative Plat Review - Request the following:
- Pg. 1 of 4, Item 1. The basement of the Indian Village Trading Post is referred to as "restaurant". Underground parking is proposed in this level.
-Request confirmation from the AZ State Preservation Office confirming this development.