08/01/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/04/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: SPEEDTANO CORP. CTR. CONDOMINIUMS
S06-169



Tucson Electric Power Company (TEP) has reviewed the final plat
submitted August 1, 2006. TEP is unable to approve the plat at this
time.



In order for this Company to approve the final plat, the following
dedication is required.



"An easement is granted for the purpose of access, installation
replacing repairing and maintenance of electrical meters, cable and
conduits, which grouped electrical meters are attached to the exterior
walls."



Show the required dedication on the resubmittal of the final plat.
Submit two bluelines to the City of Tucson for TEP's final approval.



Please contact me at (520) 917-8745 if you have any questions.



Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
08/22/2006 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor


115 N. Church Ave.


Tucson, Arizona 85701



BILL STAPLES

ASSESSOR










TO: CDRC Office

Subdivision Review

City of Tucson (FAX# 791-5559)



FROM: Gary Ault, Mapping Supervisor

Pima County Assessor's Office

Mapping Department



DATE: August 21, 2006





RE: Assessor's Review and Comments Regarding Final Plat

S06-169 Speedtano Corporate Center Condominium
T141508 (133-23)



* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *



X Plat meets Assessor's Office requirements.

_______ Plat does not meet Assessor's Office requirements.





COMMENTS: THANK YOU FOR YOUR SUBMITTAL.



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS
TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN
THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING
THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK
YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
08/28/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-169 SPEEDTANO CORP CTR CONDOMINIUM/FINAL PLAT
DATE: AUGUST 28, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Include Section Numbers on Location Map.

Spell out all street suffixes except on Location Map.

Correct the building addresses on all applicable pages.

Correct the units on building 2 pg. 1.









jg
08/30/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-169 Speedtano Corp. Ctr. Condominium: Final Plat Review - No title report received.
09/05/2006 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: September 5, 2006
CDRC/Zoning Manager

SUBJECT: Speedtano Corporate Center Condominium
7350 E. Spedway Blvd.
Final Plat S06-169 (First Review)
T14S, R15E, Section 08

RESUBMITTAL REQUIRED: Final Plat.

The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please provide North arrow and scale on the first sheet per D.S. 2-02.2.1.
2. Please include a response letter to the comments along with the corrected copies of the FP.
3. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used:
· Title Report
· Special Warranty Deed
· Trust Agreement
· Amendment to Trust
· Agreement to Construct
Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review.
4. The title block of the plat must match the Subdivision Assurances verbatim.
5. The sheet shall have a 2" margin on the left and ½" on the remaining sides per D.S. 2-03.6.1.B.
6. Please re-label all common areas that may be used in a dual and/or single use capacity per D.S. 2-03.6.4.C. For example, a Ret./Det. Basin may also be used as a recreation facility or only as a drainage facility or drainage pipe and this must be reflected on the Final Plat. A key note explaining the labels could be used in conjunction with the labels, ie.:
Common Element "A" - Streets
Common Element "B" - Drainage/Recreation Facilities
Common Element "C" - Recreation Facilities
Common Element "D" - Drainage Facilities
Common Element "E" - Landscaping
7. Show sight visibility triangles per D.S. 2-02.2.1.10.
8. Complete the case no. S06-169.
9. All verbiage shall reference common elements through out the plat instead of common areas.
10. A CCR's or a maintenance agreement for the drainage pipe shall be included on the plat with the re-submittal
11. Show total cross-sections for each building for volume calculations.
12. Show a 1' no access esmt. along the east portion of the property line.
13. Please submit a copy of the subdivision boundary closure calculations.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
7350 E. Spedway Blvd.
09/11/2006 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: SPEEDTANO CORP. CENTER CONDOMINUM
S06-169
Final Plat

TRANSMITTAL DATE: September 07, 2006

DUE DATE: August 29, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. An applicant has one (1) year from the date of submittal to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before August 28, 2007.

2. Each sheet will measure 24'x36" and include a two (2) inch margin on the left side and one-half (1/2) inch margins on the remaining sides. D.S. 2-03.6.1.B.

3. All lettering and dimensions will be the equivalent of twelve (0.12) point or greater in size. D.S. 2-03.6.1.C.

4. A small project map will be provided with the subject property approximately centered within the one (1) square mile area & the section corners labeled. D.S. 2-03.6.1.D.1 & 3.

5. Complete the subdivision case number S06-169 in the lower right hand corner. D.S. 2-03.6.1.K

6. Permiting note #1 is incorrect, the zoning is O-3.

7. The plat calls out "COMMON AREAS", the CC&R's definitions do not address "COMMON AREAS". The CC&R's definitions do define "COMMON ELEMENTS", either revise the plan so that it reflects the information provided in the CC&Rs or revise the CC&Rs to reflect the plan.

Declaration:

8. The title should reflect "SPEEDTANO CORPORATE CENTER CONDOMINIUM"

9. Article 4.3 MAXIMUM MEDICAL SQUARE FOOTAGE, should reflect the square footage specified on the approved development plan parking calculations, 9,035 sq. ft.

10. Article 4.4 SETBACKS: The set backs for the buildings on this development shall be governed by the City of Tucson Land Use Code not the Declaration or the plat. Please remove all references to building setbacks.

If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180

C\planning\cdrc\finaplat\S06-169fp.doc.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
09/13/2006 FRODRIG2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
09/14/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond September 14, 2006

TO: T. Wayne Ashby
Ashby Surveying & Drefting

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Chandubhai C. Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Speedtano Corporate Center Condominiums, Units 1-17 & Common Areas A&B
Final Plat – 1st Submittal
S06-169

The drawings for the Final Plat of the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


All Sheets. Show the project number S06-169 with large and bold letters.

2. Add the following notes in the GENERAL NOTES:

THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4

NO PERMITS FOR PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) ON OR THROUGH THE PUBLIC SEWER EASEMENT WILL BE ISSUED WITHOUT SEPARATE WRITTEN AUTHORIZATION FROM THE PCWMD.

Dedication Block: In the first line of the second paragraph, following the word TUCSON, add: ,PIMA COUNTY AND PIMA COUNTY FLOOD CONTROL DISTRICT,

3. Dedication Block: In the third line of the third paragraph, following the word to,
add: CITY OF TUCSON,

Subject to satisfactorily addressing the above comments, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat as received by us on August 1, 2006.

Please note the following: Approval of the above referenced submittal does not authorize
the construction of public or private sewer lines or water distribution lines. Prior to the
construction of such features, a Construction Authorization (Approval To Construct) may
need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the
Pima County Department of Environmental Quality prior to constructing, operating or engaging
in an activity which may cause or contribute to air pollution.

If you have any comments regarding the above comments, please do not hesitate to call me.

Sincerely,



Chandubhai C. Patel, P.E.
Telephone: (520) 740-6563

Copy: Project File
09/19/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 19, 2006

Ashby Surveying & Drafting, Inc.
717 North Swan Road
Tucson, Arizona 85711

Subject: S06-169 Speedtano Corporate Center Condominiums Final Plat

Dear Sir:

Your submittal of August 1, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Final Plat (TEP, Addressing, Real Estate, Engineering, Zoning, DSD)

2 Copies Title Report (Real Estate, DSD)

3 Copies CC&R's (Zoning, Engineering, DSD file copy)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager