Plan Number: S06-167
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-167
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/27/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator DATE: November 27, 2006

SUBJECT: Engineering review of the Estrella Home Condominiums Final Plat. The activity number is S06-167.

SUMMARY: The Final Plat and CC&Rs were received by Engineering on November 21st, 2006. Engineering has reviewed the received items and does not recommend approval of the Final Plat or the CC&Rs.

RESUBMITTAL REQUIRED: FINAL PLAT, CC&Rs

SUBMITTAL REQUIRED: TITLE REPORT, BOUNDARY CLOSURE CALCS, LOCATION MAP ON AN 8 ½ X 11 SHEET

The next submittal must address the following items:

CC&R COMMENTS

1. The table of content page numbers do not match the actual pages of the CC&Rs. Revise the page number to match the subject content in the CC&Rs.

The above comment is from the first review. It is acknowledged the table of contents has been revised, however some of the sections noted in the table of contents still do not have the correct page number. Revise appropriately.

FINAL PLAT COMMENTS

1. The distance, 55.97', located on the south boundary appears to be incorrect. When scaled to the distance 39.5', the distance is approximately 45'. Revise appropriately.

2. Describe in the title block the "Common Limited Element B." Porches? Private yard? Revise appropriately. DS 2-03.6.1.H.

3. After researching the Development Services permitting system (Permits Plus) it has been brought to my attention that the Certificate of Occupancy inspections are not complete. Therefore there is no verification that the entire site infrastructure is complete. If the site infrastructure is not complete, assurances are required to ensure that all site work has been constructed and passed inspections. Please clarify. If the intent is to provide assurances for the site infrastructure revise the plat and submit a complete assurance package. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

The above comment is from the first review. Prior to approval of this review, verification of completion and approval of all site infrastructure must occur. At minimum an Engineering Inspector must inspect the site to verify completion of the site infrastructure. If the inspection shows the project is not complete or not complete per the City of Tucson approved plans, the need for assurances may apply. Please call in for the appropriate inspections. If you have any questions regarding this matter please call me at 791-5550 extension 2206.
12/15/2006 FRODRIG2 COT NON-DSD REAL ESTATE Approved S06-167 Estrella Homes Condominiums: Resubmittal - CDRC - Final Plat Review - No comment.
12/18/2006 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: ESTRELLA HOMES CONDOMINUMS
S06-167
Final Plat (2nd Review)

TRANSMITTAL DATE: December 15, 2006

DUE DATE: December 20, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

2. The comment was not fully addressed. The location map is to be drawn at a scale of 3"=1 mile. A small project map will be provided with the subject property approximately centered within the one (1) square mile area. Identify conditions within the square mile, such as subdivisions, major streets, and railroads. Reference recorded subdivision plants by book and page number. Section, township, and range; section corners labeled. D.S. 2-03.6.1.D

3. The comment was not fully addressed. The title block references "COMMON LIMITED ELEMENT "B" (COMMON ELEMENTS). Revise to match the information on sheet 3 "LIMITED COMMON ELEMENT "B"'. The title block references "COMMON AREAS" and "COMMON ELEMENTS", revise to reference either common areas or common elements not both. If common areas are used then Common area "B" should be listed as "LIMITED COMMON AREA B" so that the references on sheet 2 are consistent with the title block. D.S. 2-03.6.1.H.

Declaration:

1. The cover sheet was not included in this submittal, please provide. The cover sheet references "COMMON AREAS A & B", Common Area B should be listed as "LIMITED COMMON AREA B" see comment 3 above.

2. Add a definition for "COMMON ELEMENT, LIMITED COMMON ELEMENT, and EXCLUSIVE ELEMENT.


If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180

C\planning\cdrc\finaplat\S06-167fp-2nd.doc.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
12/20/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-167 ESTRELLA HOMES CONDOMINIUMS/REVISED FINAL PLAT
DATE: 12/19/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Location Map must be to scale 3”=1 mile.

Change Fort Lowell Dr. to Road on Location Map.

Spell out Drive of Blacklidge Dr. on pg. 2.



es
12/21/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 21, 2006

Peter Salonga
Oracle Engineering Group
199 East Fort Lowell Road
Tucson, Arizona 85705

Subject: Estrella Homes Condominimums Final Plat

Dear Pete:

Your submittal of November 21, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Final Plat (Addressing, Engineering, Zoning, DSD)

3 Copies CC&R's (Zoning, Engineering, DSD)

2 Copies Title Report (Engineering, DSD)

2 Copies Boundary Closure Calculations (Engineering, DSD)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 292-6144
fpresubmittal