Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL- RECORD OF SURVEY
Plan Number - S06-150
Review Name: RESUBMITTAL- RECORD OF SURVEY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/27/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 11/02/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 11/16/2006 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 11/21/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: W. EL RIO DRIVE S06-150 Record of Survey (2nd Review) TRANSMITTAL DATE: November 20, 2006 DUE DATE: November 28, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. D.S. 2-03.11.0, permits a maximum of one year from the date of application to obtain approval of a Record of Survey. If, at the end of that time, the Record of Survey has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this record of survey is July 31, 2007. 2. D.S.2-03.11.7.B Each sheet will measure 24" x 36" and include a two (2) inch margin on the left side and one-half (1/2) on the remaining sides. The left margin is too small on sheet 1. 3. D.S. 2-03.11.7.D The location map is not to scale, 3" = 1 Mile. 4. D.S. 2-03.11.7.D.2 Show the Major watercourses on the map, Santa Cruz River. 5. D.S. 2-03.11.7.F.2 &3 A title block with the following information is to be provided: provide the proposed name of the Land Survey Exception; provide the number of proposed lots. Remove "LOT SPLIT (3)" from the title block. 6. D.S. 2-03.11.8.B.6 Remove Note 5 from the plan. This record of survey is not bounded or intersected by a Major Street or Route. 7. D.S. 2-03.11.9.B Under the Dedications change all references to "PLAT" to "PLAN" 8. General Comments, There is a landscape buffer called out under keynote 8, which runs along the south property line is shown running through the driveways, revise the plan. 9. There are depressed landscape areas for storm water harvesting these areas cross over proposed property lines. Provide access and maintenance agreements for these landscape areas. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\cdrc\record of survey\S06-150ros-2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Record of Survey and additional requested documents. |
| 11/27/2006 | MARILYN KALTHOFF | PIMA COUNTY | WASTEWATER | Denied | November 25, 2006 TO: Geoffrey Brimhall, R.L.S. Physical Resource Engineering, Inc. THRU: Patricia Gehlen, CDRC Manager City of Tucson, Development Services Department FROM: Chandubhai C. Patel, P.E.. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: El Rio Drive Duplexes, Rugen Construction Record of Survey - 2nd Submittal S06-150 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. Sheet 2. Show the Pima County plan number for existing public sewer line in N El Rio Drive, along with six digit Pima County manhole number(s). 2. Sheet 2. Show the invert and rim elevations for the two existing manholes located on the above mentioned sewer line. 3. Sheet 2. Show how the proposed sewers serving the three parcels (HCS) will be connected to the existing public sewer, and show the invert elevations of the existing public sewer and the HCS at the points of connection. 4. Sheet 2. The size of the HCS should be 4 inch rather than 3 inch as shown. Each of the two longer HCSs should have cleanouts where they make a 90 degree turn and at an intermediate point so that the distance between two cleanouts does not exceed 100 feet. Also, show the rim and invert elevations of these cleanouts. 5. Sheet 2. This sheet needs to be stamped by a registered professional engineer or land surveyor. 6. Sheet 1 & 2. Make the Title Blocks identical looking as these sheets are for the same project. 7. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents. The next submittal of this project will be the 3rd submittal. A check for the review fee of this submittal in the amount of $78.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai C. Patel, P.E. Phone: 520-740-6563 Copy: Project File |
| 11/28/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-150 W. EL RIO DRIVE/REVISED RECORD OF SURVEY DATE: November 27, 2006 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Correct Location Map sections. The lines and the section numbers are in the incorrect locations. C & E are in the incorrect locations on Location Map. Change H to 55093. The CL in front of the street names look like part of the street name. Please correct. Location Plan must be to scale on pg. 2. jg |
| 12/08/2006 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: December 8, 2006 SUBJECT: El Rio Drive Record of Survey- 2nd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 1308 W El Rio Dr., T14S R13E Sec02, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: S06-150 SUMMARY: Engineering Division of Development Services Department has received and reviewed the re-submitted Record of Survey. The Record of Survey is not approved at this time. The following items need to be addressed: RECORD OF SURVEY: 1) DS Sec.2-03.11.7.D: Revise the location map located on Sheet 1 of 2 to identify the Santa Cruz River. Revise the location map located on Sheet 2 of 2 to scale, 1"= 3 miles. 2) Ds Sec2-03.11.7.E: Revise the margins on Sheet 1 of 2 to provide for the required margin width. 3) DS Sec.11.7.F: Revise the title block information in the lower right corner of the first page of the Record of Survey to provide for the proposed name of the Land Survey Exception. The Title Block should read the name "El Rio Drive Duplex Lots 1-3" under the first line "Record of Survey" provided. 4) DS Sec.2-03.11.10.A: Revise the Record of Survey; course and distance must tie at least one (1) corner of the property to the section corner or the quarter section corner, or an established City or County survey monument. The plan must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plan. 5) DS Sec.2-03.11.12.A: Revise the Record of Survey to show that all proposed easements (utility, sewer, drainage, access, etc.) are dimensioned and labeled as to their purpose and whether they will be public or private. Recordation information must be included on the plan prior to final approval. The comment letter submitted only addressed the private sewers. Provide easements for electric, gas, water and all other applicable utilities. 6) DS Sec.2-03.11.12.B: Provide no-vehicular access easements in plan view between each driveway and adjacent property line so that access can not be used from one property to another. GENERAL COMMENTS: Provide a revised Record of Survey at re-submittal. The revised Record of Survey must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the Record of Survey. If you have any questions, or to schedule an appointment, I can be reached at 791-5550, extension 1189. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 12/11/2006 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review | |
| 12/11/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 11, 2006 Emanuel Torres 439 North 6th Avenue #165 Tucson, Arizona 85705 Subject: S06-150 W. El Rio Drive Record of Survey Dear Mike: Your submittal of October 30, 2006, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Record of Survey (Addressing, Engineering, Zoning, Wastewater, DSD), Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 624-5118 |